Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity was posted on July 30, 2012. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

C--PROJECT 512-12-120 DESIGN TO CORRECT ELECTRICAL DEFICIENCIES AT 4D EMERGENCY POWER RISER

Awarded
VA24512R0399Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
International
R.T. Orr Dam Geotechnical Investigations
Solicitation # 2026-05
The Upper Thames River Conservation Authority is soliciting proposals for geotechnical investigations and assessments of the R.T. Orr Dam located in Stratford, Ontario. The project, which initiates in 2026 and must be substantially completed by March 15, 2027, is based on recommendations from a 2023 Dam Safety Review by D.M. Wills Associates Limited. The scope of work includes reviewing existing structural data, conducting a detailed seepage investigation at the downstream left armour stone retaining wall, performing supplementary field investigations for embankment slope stability, installing two nested monitoring wells in both earth embankments, and updating stability analyses for armour stone structures. All work must adhere to the LRIA Technical Bulletin for Geotechnical Design and Factors of Safety and meet Ontario Accessibility Standards for electronic deliverables. Proposals must be submitted electronically via the bids and tenders platform by 3:00 PM Eastern Daylight Time on November 18, 2026. The selection process utilizes a two-envelope system where technical qualifications in Envelope A are evaluated before the cost proposal in Envelope B is opened. Award decisions are based on best value, considering experience, understanding of the work, proposed methodology, schedule, and cost reasonableness. Selected consultants must provide proof of professional licensing, WSIB standing, and required insurance policies, while maintaining strict confidentiality regarding project information.
Upper Thames River Conservation Authority

POSTED

about 10 hours ago

DEADLINE

in 21 days
NAICS: 541330
New
SLED
Oso Parkway/Pacific Park Drive/Glenwood Drive Regional Traffic Signal Synchronization Project
Solicitation # 20261026016
The City of Aliso Viejo is soliciting proposals for a professional licensed consultant to provide regional traffic signal synchronization services for the Oso Parkway, Pacific Park Drive, and Glenwood Drive corridor. The project involves coordinating traffic signals across multiple jurisdictions, including the Cities of Aliso Viejo, Laguna Hills, Mission Viejo, Laguna Niguel, the County of Orange, and Caltrans, extending from Moulton Parkway to the SR-241 Northbound On-Ramp. The projected period of performance is from April 1, 2027, to September 30, 2030. The selected consultant will be responsible for providing all necessary labor, materials, and equipment to implement optimized signal timing in accordance with the Regional Traffic Signal Synchronization Master Plan and the City's Local Signal Synchronization Plan. Proposals are due by December 2, 2026, and must be submitted as one hard copy and one electronic PDF on a USB drive, with the cost proposal in a separate sealed envelope. Award decisions will be based on a weighted evaluation of the consultant's ability and skills, character and reputation, cost reasonableness, ability to meet time requirements, financial resources, and previous experience with the vendor. The contract is governed by the laws of the State of California with venue in Orange County. Key requirements include compliance with California prevailing wage laws, adherence to the City's Minority Business Enterprise program, and the submission of annual political contribution disclosures.
City of Aliso Viejo

POSTED

about 12 hours ago

DEADLINE

in about 1 month
NAICS: 541330
New
SLED
Buckhead CID Livable Centers Initiative Master Plan
Solicitation # 2026-10
The Buckhead Community Improvement District is soliciting proposals for the Buckhead Livable Centers Initiative Master Plan, a project aimed at updating the 2017 LCI plan to improve accessibility, walkability, and transit use. The scope of work focuses on the Buckhead and Lenox MARTA station areas and their connected mixed-use districts. Key deliverables include an existing conditions assessment report, a regulatory code study and audit, and the advancement of both a central gathering place/park plan and a walkable streetscape prototype to 30 percent completion. The total budget for this project is 300,000 dollars, with payments made via monthly invoices and progress reports. The project is funded through the Atlanta Regional Commission’s Livable Centers Initiative program and must adhere to federal regulations 49 CFR Part 18 and 49 CFR Part 26 regarding competitive procurement and Disadvantaged Business Enterprise participation. Additionally, the contractor must comply with the Georgia Security and Immigration Compliance Act and the Clean Air Act Amendments of 1990. The performance period begins with a notice to proceed on December 21, 2026, with a project kickoff in January 2027 and a final completion deadline of November 19, 2027. Selection will be based on the consultant's qualifications, prior experience, proposed approach, and understanding of the local Buckhead context.
Buckhead Community Improvement District

POSTED

about 13 hours ago

DEADLINE

in 16 days

General Info

Agency

N/A

Contract Value

$73,488.77

NAICS

541330 - Engineering Services

Place of Performance

VA MARYLAND HEALTHCARE SYSTEM;VA MEDICAL CENTER;10 N. GREENE STREET;BALTIMORE, MD 21201 USA

Set-Aside

SDVOSBC

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Presolicitation

Notice updated

The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
ARCHITECT-ENGINEER (A/E) DESIGN SERVICES: This A/E Services contract is being procured in accordance with the Brooks Act (Public Law [PL] - 582) and implemented in by the Federal Acquisition Regulation (FAR) Subpart 36. Firms will be selected for negotiation based on demonstrated competence and qualifications for the required work. VA Maryland Healthcare System is seeking qualified A/E firms to furnish professional services to survey and design the existing emergency power distribution systems in several areas serviced by the "D-Quad" Riser and determine the extent of the deficiencies, and provide recommendations to correct the problems. A 120/208V electrical panel on the 4th floor, "4D-E2" that is supplying emergency power to equipment, devices, and sub-panels that require power far beyond the capacity of the panel. During emergency power and circuit breaker-testing, it was discovered that several of the circuit breakers serviced by panel "4D-E2" would trip when power switched from normal to emergency. It is suspected that the surge of power overloads the panels, causing outages which present potential issues during an emergency situation. The results of this Design Project will lead to a construction project that will address the deficiencies. Designs shall minimize electrical outages and disruptions to normal hospital activity. The scope of this project shall consist of, but not limited to: oSurveying and inspecting the existing conditions of the emergency power distribution system. This includes the D-quad Rriser as well as other potentially-problematic risers. Coordinate all surveys and site visits with the VA COTR and Maintenance staff -Identify panels that feed sub-panels-both normal and emergency power-and determine if corrections are needed. oPresenting findings of survey to VA COTR and Maintenance staff and discuss solutions -For any panels identified as potential concerns (including 4D), provide an electrical study of no less than 6 hours in duration to monitor the following: -Kilowatts (kW) -Ampere/phase -Volt-amperes (VA) -Inductive reactive power (kvarL) -Capacitive reactive power (kvarC) -Power factor (PF) -Frequency (Hz) -Kilowatt hours (kWh) -Reactive power per hour (kvarhL, kvarhC) -Total harmonic distortion (%THD) -Harmonic factorization (FFT) to 51st harmonic -Evaluate potential loads vs. panel load capacities. Provide an analysis of potential impact if one or more panels should fail. -Evaluate any governing device (breaker, fuse, etc.) to ensure that it is appropriate -Evaluate the capacity of the cable supplying each panel to ensure proper sizing oProviding designs/construction documents to correct any deficiencies found. -Submission and design requirements are outlined in further detail below -Provide plans to indicate impact of any necessary outages as part of corrections, including areas/equipment affected, estimated duration of outage, phasing, etc. -Provide designs for the replacement of electrical panel covers oRevising as-built drawings for any proposed work (specifically, drawings 1E-138, 1E-139, 1E-140, & 1E-140) oProviding Construction Administration services, including the evaluation of proposals, construction project management, inspection of all proposed work, and final testing and acceptance to verify effectiveness of corrections. oProviding a power analyzer, Ideal 800 Series Power Analyzer or approved equal, and all necessary clamps, leads, and connections to aid the VA maintenance staff in monitoring the distribution system. This project consists of preparing complete construction and demolition drawings with specifications for bid purposes. The drawings shall meet all applicable federal, state, and local governing codes. Drawing shall be stamped by discipline by registered architects and engineers of the prime SDVOSB Firm. THIS PROCUREMENT IS A 100% SET-ASIDE FOR SERVICE DISABLED VETERANS OWNED SMALL BUSINESS FIRMS. Before a SDVOSB is proposed as a potential contractor, they must be verified by VETBIZ and registered in the Central Contractor Registration (CCR) database. Register via the CCR internet site at http://www.ccr.gov. Failure of a proposed SDVOSB to be verified by the CVE at the time the SF330 is submitted will result in their elimination as a proposed contractor. The proposed services will be obtained by a Negotiated Firm-Fixed Price Contract. The NAICS Code for this acquisition is 541330 and the applicable Small Business Size Standard is not more than $14.0M average annual gross revenues for the past three fiscal years. The construction cost range for this project is between $500,000 and $1,000,000. The following evaluation criteria in accordance with FAR 36.6 will be used during the A/E selection process: (1) Professional qualifications necessary for satisfactory performance of required services; (2) Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials; (3) Capacity to accomplish the work in the required time; (4) Past performance on contracts with government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules; (5) Location in the general geographical area of the project and knowledge of local conditions and codes. Firms will be evaluated by the A/E Evaluation Board, scored, and ranked according to score. The three most qualified firms will be invited to interview with the selection board, and will again be scored. The firm with the highest score will be selected and asked to negotiate a fair and reasonable price. Due to the need of multiple site visits and coordination on design reviews, consideration is limited to A/E firms with a working office located within a 100 miles radius of the VA Medical Center, 10 N. Greene Street, Maryland 21201. This distance is determined according to www.randmcally.com. Interested firms that meet the requirements listed in this announcement are invited to submit one (1) copy and one CD-ROM of SF 330 Part I and Part II to the Contracting Officer, Attn: Sandra Anderson, VA Medical Center, Building 101B, Room 9, Laundry Drive, Perry Point, MD 21902, and reference the announcement number and project title listed NLT 2:30 PM (EDT), August 27, 2012. SF 330 Forms can be obtained at http://www.gsa.gov/Portal/gsa/ep/formslibrary. Fax or electronic submissions will not be accepted. Interested parties shall ensure current State Licensing, and shall have current registration in the Central Contractor Registration (CCR) database at http://ccr.gov at the time of submission of SF 330 Forms. In addition, to current annual Representations and Certifications must be filed online at https://orca.bpn.gov. THIS IS NOT A REQUEST FOR PROPOSAL. A solicitation will only be issued to the most highly ranked, qualified SDVOSB A/E firm. Point of Contact is Sandra Anderson, +1 (555) 000-0000 x6005, or contact@example.gov THIS REQUIREMENT IS SUBJECT TO AVAILABLITY OF FUNDS.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS