Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

C1DA--534-24-916 Renovate Hematology & Chemistry (VA-25-00020282)

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This project involves professional engineering services for the design and construction administration of the Hematology and Chemistry lab renovations at the Ralph H. Johnson Health Care System in Charleston, South Carolina. The scope of work includes replacing flooring and casework, modifying electrical outlets, capping gas fixtures, updating ceiling grids, and installing specialized lab-grade sinks and wall-mounted cabinets. The construction magnitude is estimated between $300,000 and $400,000, with a target completion period of 195 calendar days following the award. The opportunity is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 541330. Interested firms must submit an electronic SF330 by February 6, 2025, at 1500 EST. Selection will be based on the Brooks Act, evaluating specialized experience, technical competence, past performance, professional qualifications, and the firm's capacity to perform the work. The anticipated award date for the architecture and engineering contract is on or before July 2, 2025.

General Info

SDVOSB engineering services for Ralph H. Johnson lab renovations, estimated $300k-$400k.

NAICS

541330 - Engineering Services

Place of Performance

Ralph H. Johnson VA Health Care System 109 Bee St, Charleston, GA, 29401, USA

Set-Aside

SDVOSBC

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

pre-forecast

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 247-NETWORK Contract Office 7 (36C247)
Contacts1 person available
OfficeAUGUSTA, GA, 30904, USA
Office AddressAUGUSTA, GA, 30904, USA
Contacts
Kenyon E. DulaneyContract Specialist

Full Description

Show more
Predicted recompete opportunity based on federal award data.
Current Contract: 36C24725C0112 Incumbent: THINKFORM DESIGN ARCHITECT LLC Contract Value: $94,956.31 Potential End Date: 2026-11-01T00:00:00.000Z Competition: FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES Pricing: FIRM FIXED PRICE Classification: full-recompete (Confidence: high - 80/100)
This Pre-solicitation Notice is NOT A REQUEST FOR PROPOSAL. ALL INFORMATION NEEDED TO SUBMIT SF330 DOCUMENTS ARE CONTAINED HEREIN. NO ADDITIONAL SOLICITATION PACKAGE OR TECHNICAL INFORMATION WILL BE ISSUED. Project: 534-24-916 Hematology & Chemistry Renovation Work Location: Ralph H. Johnson Health Care System, Charleston, SC Estimated/Target Completion Period: 195 calendar days after Award. Construction Magnitude: Between $300,000 and $400,000 NAICS: 541330 Engineering Services Small Business Standard: $25.5 Million Set-Aside: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) Site Visits will not be arranged during this phase. The anticipated award date of the proposed A-E Contract is on or before 2 July 2025. SF 330 Date of Receipt/Due Date: Interested firms having the capabilities to perform this work must submit one (1) electronic SF330 and attachments if any, no later than (NLT) 6 February 2025 1500 EST. PROJECT OVERVIEW: Provide professional engineering services for the design and construction administration to renovate the Hematology and Chemistry labs in accordance with the TIL and all applicable codes, standards, and regulations. Remove ACT flooring and replace with vinyl sheet flooring, replace existing casework with new casework as specified, move all outlets in existing casework to the adjacent wall, remove all gas fixtures and cap at the nearest junction/hub in accordance with NFPA 55, replace all ceiling grid and tile in work areas as needed, repaint work areas to match existing color as needed. Provide a dual sink, lab grade, with a goose neck spigot incorporating a spray nozzle with hose. Spigot shall have hands off temperature control, either by foot pedals or other approved method. Provide means to cover the sink for use as counter when needed. Remove existing hood back to the nearest junction and cap. Install wall mounted cabinets as shown on drawing. Remove existing hood back to the nearest junction and cap. Provide a dual sink, lab grade, with a goose neck spigot incorporating a spray nozzle with hose. Spigot shall have hands off temperature control, either by foot pedals or other approved method. Provide means to cover the sink for use as counter when needed. Install wall mounted cabinets as shown on drawing. SDVOSB SET-ASIDE: This requirement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses under the authority of 38 U.S.C. 8127(d). To be eligible for award the SDVOSB you must be considered small under the relevant NAICS code. SDVOSB contractors must be verified and viewable in Small Business Administration Veteran Small Business Certification (VetCert) database https://veterans.certify.sba.gov prior to submission and prior to award of contract with VAAR 804.1103-70. Status as a qualified SDVOSB concern is under the authority of 38 CFR Part 74 in accordance with the VA Acquisition Regulation (VAAR) Part 819. Any person, persons, or business entity suspected of misrepresenting itself for the purpose of securing a government contract may be criminally investigated and prosecuted for fraud against the United States of America. Parties found misrepresenting their status also risk debarment from further Government contracts. Eligible SDVOSB concerns must also be registered at the following websites: System for Award Management (SAM): https://www.sam.gov/ VETS100/100A Report must be complete: http://www.dol.gov/vets/vets4212.htm Important Notice: Prior to submitting a package under this SDVOSB set- aside solicitation; offerors must apply for and receive verification from the Small Business Administration in accordance with 38 CFR Part 74 and VAAR 819.70 by submission of documentation of Veteran status, ownership, and control sufficient to establish appropriate status. All offerors are urged to contact the SBA and submit the required documents to obtain verification of their SDVOSB status if they have not already done so. For a Service-Disabled Veteran Owned Small Business (SDVOSB) to be considered as a prospective contractor, the firm, including Joint Ventures, must be verified and registered in the Small Business Administration Veteran Small Business Certification (VetCert) database (https://veterans.certify.sba.gov) and registered in the System for Award Management (SAM) database (www.sam.gov) at time of submission of their qualifications. Failure of a prospective SDVOSB to be verified by the Center for Veterans Enterprise (CVE) at the time the SF 330 is submitted shall result in elimination from consideration. All Joint Ventures must be CVE verified at time of submission and submit agreements that comply with 13CFR 125.15 prior to contract award. SF 330 SELECTION CRITERIA: Specialized experience and technical competence in the type of work required. Submission Requirements: SF 330 information shall be provided per the latest format from the GSA Library located at https://www.gsa.gov/forms-library/architect-engineer-qualifications. Complete using blocks F. and H. of the SF330 form. Complete block F. for each relevant project. Complete block H. summary sheet for the Offeror and each key consultant; each summary sheet shall be not more than one (1) page in length. Submit no more than five (5) projects similar to required work in the solicitation from the date the solicitation closes to five (5) years prior. At minimum, three (3) projects must be construction complete or construction substantially (50%+) complete. Projects/data submitted shall be projects with total construction costs of $400,000, greater. Projects may include Federal, State, or local Government, as well as private industry projects. Offerors are responsible for providing project description and applicable information in sufficient detail to permit evaluation of project relevancy versus these minimum requirements. Basis of Evaluation: Specialized experience pertains to the types, size, volume, budget, and complexity of work previously or currently being performed by the Offeror that is comparable to the work covered by this solicitation. Specialized experience may also include unique conditions, considerations, or circumstances encountered that are relevant to this solicitation. Specialized experience does not include overseas offices for projects outside the United States, its territories, or possessions; nor does it include subsidiaries that are not normally subject to management decisions, accounting, and policies, or a holding or parent company or an incorporated subsidiary that operates under a firm name different from the parent company. Technical competence includes construction and design projects similar in project scope, size, construction features, dollar value, and complexity of that listed in the solicitation. Technical competence also includes experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Similar complexity is considered projects of an operational, construction, or design likeness to the work covered in the solicitation. Specific emphasis of experience and technical competence shall be geared towards fire protection. Adjectival Scoring: Offerors unable to demonstrate proven specialized experience and technical competence for relevant projects may be considered non-responsive or scored negatively. Failure to provide requested data may negatively impact an Offeror's rating. Past Performance on contracts with Government agencies and private industry in terms of cost control, quality work, and compliance with performance schedules. Submission Requirements: Complete a Summary Sheet using block H. of the SF 330 describing the Offeror s past performance. The summary sheet shall be not more than two (2) pages in length. Provide the Contractor Performance Assessment and Reporting System (CPARS), interim and final reports, for each submitted Federal entity project under Specialized Experience criteria, above. If a CPARS is not available, provide a PPQ. If a relevant project submitted under Specialized Experience criteria does not have a CPARS because it is a non-Federal entity project, provide a Past Performance Questionnaire (PPQ). CPAR and PPQ reports will not count towards page limitations. Basis of Evaluation: Past performance is a measure of the degree to which an Offeror satisfied its customers needs and requirements and compliance with applicable codes, standards, laws, and regulations. The evaluation of past performance will include but is not limited to: The customer s assessment of the Offeror's commitment to customer satisfaction. Timely delivery of quality work. The Offeror's record of conforming to contract requirements and applicable codes, standards, laws, and regulations. Successful implementation of a quality control plan and quality control procedures. Addressing design errors/omissions timely. Adherence to approved schedules. History of timely and professional communication and cooperative behavior. Include information on problems (errors/omissions) found, how the problems were corrected, and the impacts to the successful completion of the project (time delays, cost impacts, design modifications, etc.). Provide information supporting favorable cost control, quality of design submissions, and schedule compliance. Include a discussion on the Offeror s record of significant claims for improper or incomplete design services. Higher ratings may be given for work performed on VA Medical Center campuses. Adjectival Rating: Offeror risks receiving a lower rating if fewer than three (3) PPQs are provided or if the PPQs were not completed by project point of contact. Failure to provide requested data or to provide an accessible point of contact (POC) may negatively impact an Offeror's rating. Failure to demonstrate proven competence to perform projects like the requirements of the solicitation may be considered ineligible for award. If no CPARs or PPQs are submitted or responses to requests were not provided, the rating shall be Neutral . Professional qualifications necessary for satisfactory performance of required services. Submission Requirements: Complete using block E. of the SF 330. Submit personal resumes and relevant information for key and responsible personnel. Block E. shall be not more than one (1) page in length per individual. The Offeror shall have a professional engineer, currently registered in any US state or territory of the United States, knowledgeable in their registered design discipline, to be the lead designer responsible for reviewing and approving design submissions. The Offeror shall have a professional engineer, qualified and knowledgeable of South Carolina state and local regulations, be the lead designer responsible for reviewing and approving design submissions and facilitating permit documentation (depending on the nature of the design i.e. environmental, hazardous material abatement, stormwater, etc.). Key personnel to provide qualifications to meet this criterion include Principal(s), Project Manager(s), key consultants, individuals responsible for implementation of the Design QA/QC Plan, Licensed Fire Protection Engineer, Licensed Asbestos Inspector, Physical Security Specialist, Life Safety Specialist, and other individuals that are responsible or accountable for design submissions and regulatory compliance. Physical Security Subject Matter Experts shall meet the requirements of Section 10.1.5 of the Physical Security & Resiliency Design Manual. Basis of Evaluation: Evaluation of professional qualifications will include but is not limited to the subjective assessment of the Offeror's individual resumes. The Offeror shall describe and/or depict which projects and how well key personnel of the design team have worked together. Higher ratings for this criterion may be given when the Offeror's specific personnel demonstrate relevant credentials, such as involvement and degree of involvement in professional organizations, research/publications, code/standard body involvement, etc. Adjectival Scoring: Offerors unable to demonstrate professional qualifications necessary to perform designs may be considered non-responsive . Failure to provide sufficient data supporting professional qualifications may negatively impact an Offeror's rating. Failure to provide all key personnel and key personnel requirements shall result in no greater than a marginal rating. Experience in construction period services. Submission Requirements: Complete using block H. of the SF 330. Provide a narrative that describes the Offeror s performance completing Construction Period Services (CPS) for construction for each submitted project under Specialized Experience criteria, above. Narrative shall be not more than two (2) pages in length. Basis of Evaluation: Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services. Evaluation of the Offeror s knowledge, skills, and abilities to complete necessary CPS to support successful project completion. Provide a narrative describing the below services, but not limited to: Professional field inspections, both scheduled and emergent. Maintaining a comprehensive submittal log inclusive of material data, shop drawings, certifications, etc. Review of construction submittals for design conformance, variance, and applicable code/standard compliance. Providing timely and complete responses to requests for information. Providing supporting documentation (statements of work, cost estimates, technical reports, etc.) for construction modifications. Providing record drawing documentation. Process for correcting design errors/omissions identified during construction; and, Other requirements defined under CPS in the Statement of Work. Capacity to accomplish the work in the required time. Submission Requirements: Complete using block H. of the SF 330. Provide a narrative that describes the Offeror s work capacity. Narrative shall be not more than one (1) page in length. Basis of Evaluation: Identify the Offeror s past, present and projected future workload, including VA contracts over the previous 12 months. Describe the Offeror s capacity to incorporate this solicitation s work while meeting prescribed dates for current workload. Each key team member to include % of available capacity to take on new projects. Evaluation of this factor will be an assessment of the Offeror s ability to complete design documents within the period of performance and meet solicitation requirements. Data is acceptable in tables or charts. Capacity < 25% shall be rated no greater than Marginal. Higher ratings may be given for this criterion when information provided exceeds the minimum requirements. Location in the general geographical area of Charleston, SC, and knowledge of the locality of the Ralph H. Johnson VA facility: Submission Requirements: Complete using block H. of the SF 330. Provide a narrative that describes the Offeror s experience in the Charleston, SC geographical area. Narrative shall be not more than one (1) page in length. Basis of Evaluation: Offerors will be subjectively evaluated based on their knowledge (and the knowledge of subcontractors) of unique conditions or variables, such as familiarity of applicable codes, regulations, construction market & labor conditions, geotechnical, seismic, weather, environmental, or other unique considerations found in Charleston, SC and the Low Country geographical area. If prior experience in Charleston, SC is minimal, describe how the design team plans to obtain specific knowledge of local conditions or project features required for a compliant design. Data from other projects and locations are acceptable to highlight knowledge of the Charleston, SC geographical area or areas of similar nature. Adjectival Scoring: Offerors that submit relevant projects outside of the Charleston, SC geographical area may be given a lower rating than projects within the Charleston, SC geographical area. Offerors that demonstrate no experience in the geographical area shall be rated neutral . The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors: Submission Requirements: Complete using block H. of the SF 330. Provide a narrative that discusses the Offeror s approach. Narrative shall be not more than one (1) page in length. Offerors shall complete and submit the following statement in block H. : I [signatory authority], of [Offeror Company or Joint Venture] certify that the team proposed to perform under this requirement demonstrates the capability of 50% SDVOSB performance in compliance of 48 CFR 852.219-10 . Basis of Evaluation: Offerors shall be evaluated based on their utilization plans for service-disabled Veteran-owned small businesses (SDVOSBs), Veteran-owned small businesses (VOSBs), or other types of small businesses. Offerors shall be evaluated on the expected amount of work versus key personnel to verify the above signatory statement. If less than 50% of work is estimated to be performed by the prime SDVOSB, the Offeror may be given a lower rating. Offerors shall submit qualifications for proposed consultants per other criteria in this solicitation. SELECTION PROCESS: Federal Acquisition Regulation (FAR) Part 36.6 (Brooks Act) selection procedures apply. The A-E Services listed herein is being procured in accordance with the Brooks Act (Public Law 92-582) as implemented in Federal Acquisition Regulation (FAR) 36.6 and VAAR 836.6. Pursuant to FAR, the firm responding to this requirement must be permitted, by law, to practice the professions of architecture or engineering and meet all required qualifications for the state of South Carolina. Firms responding to this announcement by submitting a qualifying SF 330, before the closing date and time, will be considered for initial selection evaluation. Following initial evaluation of the SF330s received three or more firms that are considered the most highly qualified to provide the type of services required will be selected for interviews. Selected firms will be notified by email of selection and provided further instructions. Selection and evaluation of firms shall be made based on SF 330 submissions and direct responses to the selection criteria identified herein. Failure to address all selection criteria will result in a decreased rating. Evaluating past performance and experience may include information provided by the firm, customer inquiries, Government databases, and Contracting Officer knowledge of current project performance. Failure to provide requested data, accessible points of contact or valid phone numbers could result in a firm being removed from consideration. Firms that design or prepare specifications in conjunction with this contract are prohibited from participating on any future construction contracts based on those documents. All projects identified on the SF330 must be completed by the office/branch/individual team member performing the work under this contract. SUBMISSION CRITERIA/REQUIREMENTS: The SF 330 form may be downloaded from http://www.gsa.gov/portal/forms/type/SF. Completed SF 330 s shall include the primary firms, subcontractor firms and any consultants expected to be used on the project. Do not submit information incorporating by reference. Prospective firms shall address all selection criteria factors within their submitted SF330 packages. Email capacity is limited to five (5) to seven (7) megabytes (Megs). The following format shall be used: Cover Page with Solicitation Number, Project Title Table of Contents SF 330 s Copy of Current A/E License Copy of current vetBiz.gov SDVOSB certification UEI Number Cage Code Tax ID number The E mail address and Phone number of the Primary Point of Contact. All SF330 submittals and questions must be sent electronically to the attention of Cayley Blommers, Contract Specialist at contact@example.gov. Please provide Pre-Solicitation Number, Project Number, Project Title, and Firm Name in Subject Line of email. When submitting SF330s, if more than one email is sent, please number emails in Subjects as 1 of n . Submittals received after the date and time identified on page one (1) will not be considered. Firms not providing the required information may be negatively evaluated. Facsimile submittals will not be accepted. All information must be included in the SF330. The SF-330 including title page, table of contents, and any other relevant information shall not exceed a total of 50 pages in a common font size 12 font, single spaced. The package shall be submitted as a single application-generated (not scanned), searchable PDF document. A page is defined as each face of an 8.5 X 11-inch sheet of paper containing information. The page limitation does not apply to the licenses, contract performance evaluations, (i.e., CPARS) and award documentation. This information should be provided as attachments to the SF 330. It is the offeror s responsibility to check the SAM.GOV Contracting Business Opportunities website at: www.sam.gov for any revisions to this announcement prior to submission of SF330s. ATTACHMENTS: See attached document: AE Past Performance Questionnaire and Cover Letter.

Similar Contracts

Same NAICS industry code

NAICS: 541330
New
SLED
Road Asset Management
Solicitation # FY27-ENGCP-002-6
The Bulloch County Board of Commissioners is soliciting Statements of Qualifications for project FY27-ENGCP-002-6, focused on Road Asset Management. The selected consultant will be responsible for collecting and analyzing field data, creating a road asset inventory, and developing a Capital Improvement Plan with an outlook extending to FY 35. The scope includes GIS database development, web-based mapping, and the identification of structural hazards and drainage failures to minimize safety risks and legal liability. All prime and sub-consultants must be GDOT Prequalified Contractors as of the submission deadline on November 20, 2026, at 3:00 PM EDT. Proposals are evaluated based on a composite scoring system that weights prime consultant experience and technical approach at 20% each, GIS capabilities at 20%, asset prioritization methodology at 15%, workload capacity at 15%, and past references at 10%. The highest-ranked consultant will be invited to negotiate a contract. Key requirements include a Principal-in-Charge with at least 10 years of industry experience and comprehensive insurance coverage, including professional malpractice and general liability of at least 1 million dollars per occurrence. Submissions are limited to ten pages, excluding mandatory forms and charts, and must include a Non-Collusion Affidavit and Bidder Declaration. Either party may terminate the resulting agreement with 30 days written notice.
Bulloch County Board of Commissioners

POSTED

about 5 hours ago

DEADLINE

in 22 days
View Details
NAICS: 541330
New
International
CoT RFP Event Q30-01-2026-27
Solicitation # Q30-01-2026-27
The City of Tshwane is soliciting a service provider for professional engineering services to support town planning subdivision application processes on city-owned properties. The scope of work is divided into three primary categories: Civil Services Reports, Geotechnical Investigations, and Route Determination Reports. All services must be led by a Professional Engineer registered with the Engineering Council of South Africa and must comply with the Gauteng Transport Infrastructure Act, National Building Regulations SANS 10400, and various SANS and SANRAL standards. The project follows a strict timeline, requiring an inception meeting within one month, draft reports within three months, final reports within five months, and project close-out within six months of appointment. The solicitation, numbered Q30-01-2026-27, closes on November 12, 2026, at 10:00. Awards are based on an 80/20 preferential point system in accordance with the Preferential Procurement Policy Framework Act and 2022 Regulations, with specific goals including points for women-owned, youth-owned, and disability-owned enterprises, as well as local economic participation. Evaluation occurs in four stages, starting with administrative responsiveness and a functionality score of at least 70 out of 100. Successful bidders must enter into a Service Level Agreement, with payment terms set at 30 days following the receipt of an invoice. Required submission documents include company registration, tax clearance or a CSD unique pin, and B-BBEE certification.
City of Tshwane

POSTED

about 8 hours ago

DEADLINE

in 13 days
View Details

More opportunities from Department Of Veterans Affairs → 247-NETWORK Contract Office 7 (36C247)

Same awarding agency

NAICS: 485991
New
Federal
Charleston VAMC wheelchair transportation service
Solicitation # 36C24726R0123
The Department of Veterans Affairs, Ralph H. Johnson VA Medical Center, is soliciting proposals for a five-year Indefinite-Quantity contract to provide non-emergency ground wheelchair transportation services in Charleston, South Carolina. This requirement is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and has an anticipated period of performance from December 1, 2026, to November 30, 2031. The contractor will be responsible for providing all personnel, ADA-compliant vehicles, and equipment to transport Veteran patients between VA facilities, community hospitals, and personal residences. The contract features a guaranteed minimum of $25,000 for the initial fiscal year and a total ceiling of $22,000,000. The pricing structure is based on a wheelchair load fee covering the first 25 one-way trip miles and 30 minutes of waiting at each end, with additional fees for mileage beyond that limit. Award will be based on the most advantageous offer, with technical experience in similar healthcare transportation services weighted as more important than price. Key requirements include the submission of a Quality Control Plan, strict adherence to HIPAA and privacy training, and the maintenance of high customer service standards. Proposals must be submitted in PDF format to the designated contracting officer by November 16, 2026, and must include a signed SF 1449, a Business Associate Agreement, and evidence of required insurance.
Special Needs Transportation

POSTED

about 14 hours ago

DEADLINE

in 17 days
View Details
NAICS: 236220
New
Federal
Y1DA--FY27 NRM | 619-24-103 | Replace Flooring & Repair Walls in Building 1 (VA-27-00012190)
Solicitation # 36C24727R0009
This Firm Fixed Price Construction contract, identified as project 619-24-103, involves the renovation of designated interior areas of Building 1 at the Central Alabama Veterans Health Care System, West Campus in Montgomery, Alabama. The scope of work includes replacing flooring, repairing and painting walls, installing wall-protection systems and handrails, refinishing doors and frames, and replacing water fountains with bottle-filling stations. The project is estimated to have a magnitude between 1,000,000 and 5,000,000 dollars with a target completion period of 365 calendar days from the award or notice to proceed. Because the work occurs in an operational medical facility, the contractor must implement phased execution, infection-control containment, and interim life-safety measures to protect patients and staff. This acquisition is a 100 percent set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) under NAICS code 236220. Eligible firms must be registered in the SAM database and certified in the SBA database. Per VAAR Clause 852.219-75, special trade contractors are limited to paying no more than 75 percent of the government contract amount to firms that are not certified SDVOSBs or VOSBs. The government will utilize a Trade-Off Source Selection process to determine the best value. This notice is a presolicitation; formal proposals should not be submitted until the official RFP is posted, which is expected on or about November 16, 2026.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 14 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS