Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on October 11, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

C1DA--589A7-21-132 CONSTRUCT CENTRALIZED EMERGENCY POWER SYSTEM

Awarded
36C25522R0115Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
2026 CPRG NCD SOQ
Solicitation # 2026-SOQ-004
The City of Rogers is soliciting Statements of Qualifications (SOQ) under solicitation number 2026-SOQ-004 for Natural Channel Design services to restore approximately 4,200 linear feet of stream in an urban setting. The scope of work includes engineering, plan design, hydrologic and hydraulic modeling, and the procurement of all necessary local, state, and federal regulatory permits, including potential Letter of Map Revision submissions to FEMA. This project is funded by the Climate Pollution Reduction Grant (CPRG) subaward CPRG-NWA-001 and EPA award 02F75801, requiring compliance with EPA nondiscrimination regulations, Title VI of the Civil Rights Act of 1964, and 40 CFR Parts 5 and 7. Key milestones include the completion and approval of construction plans and permit applications by May 1, 2027, with final construction completion targeted for December 31, 2027. Selection is based on a ranking of qualifications rather than price, with the highest-ranked firm invited to negotiate a contract. Evaluation criteria focus on professional staff expertise, past performance, understanding of the scope, and the quality of the work plan. Interested firms must submit a PDF via OpenGov or hard copy to Colt Craig by November 10, 2026. Submissions are limited to 25 pages and must include Standard Form 330 Part II, an Equal Employment Opportunity policy, the Arkansas DFA Illegal Immigrant Contractor Disclosure Form, and EPA certifications regarding debarment and lobbying for contracts exceeding 100,000 dollars. Additionally, firms must maintain active registration in SAM.gov and demonstrate a commitment to DBE goals through six good faith efforts in subcontracting per 40 CFR 33.301.
Community Development

POSTED

about 5 hours ago

DEADLINE

in 12 days
NAICS: 541330
New
International
Pump Optimisation and Aeration Efficiency Analysis
Solicitation # FA2253
Thames Water Utilities Limited is establishing a single-lot, sole-supplier framework agreement under solicitation FA2253 for pump optimisation and aeration efficiency services. The contract focuses on the monitoring, testing, and analysis of pumping and aeration systems across approximately 60 operational sites, encompassing roughly 200 tests during the AMP period. The primary objective is to reduce whole-life costs and improve operational performance through a structured delivery model that includes site identification, efficiency studies, and performance monitoring. The agreement will feature fixed pricing structures based on an agreed rate card and will be managed through key performance indicators to ensure strategic partnership and continuous improvement. The contract is scheduled for an initial three-year term starting May 10, 2027, with potential extensions up to a maximum of eight years, ending May 9, 2035. Eligible suppliers must demonstrate a proven track record of delivering measurable savings and innovation and must have the capacity to operate within London, the Thames Valley, and the Home Counties. Award selection is based on a 50% technical and 50% commercial weighting. The procurement process is a multi-stage procedure requiring a Pre-Selection Questionnaire via SAP Ariba by October 19, 2026, followed by an Invitation to Negotiate stage. Successful providers must also meet stringent insurance requirements, including 15 million pounds for public and products liability and 10 million pounds for professional indemnity.
Thames Water Utilities Limited

POSTED

about 5 hours ago

DEADLINE

N/A

AI Contract Overview

Show more

Solicitation 36C25522R0115, issued by the Department of Veterans Affairs Network Contract Office 15, sought qualified Architect and Engineering firms for Project 589A7-21-132 to construct a Centralized Emergency Power System at the Wichita VA Medical Center in Kansas. This project was designated as a Service-Disabled Veteran-Owned Small Business set-aside under NAICS code 541330. Amendment 001 modified the requirements by removing all kitchen design elements and establishing strict submission guidelines, including a 50-page limit for SF330 packages and a requirement for firms to be based within the United States. Evaluation scoring favored Architectural Prime Contractors located within a 1,000-mile radius of the medical center, and failure to verify a primary physical business address resulted in a non-responsive determination. The contract was ultimately awarded on August 31, 2023, to Miller-Remick, LLC. The total award amount for the construction of the Centralized Emergency Power System was 2,454,805.61 dollars under contract number 36C25523C0096.

General Info

Contract Value

$2,458,951.25

NAICS

541330 - Engineering Services

Place of Performance

KS, USA

Set-Aside

SDVOSBC

Award Issued Date

Documents

1

Award 36C25523C0096 - Construct Centralized Emergency Power System

DOCX, Low priorityaward
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseAwarded
Posted

Presolicitation

Notice updated

Set-aside added: Service-Disabled Veteran-Owned Small Business Set Aside. The notice description changed. The point of contact changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA
Contacts
Sean JacksonContracting Officer

Full Description

Show more
Page 23 of 23 Synopsis: Request for Architect-Engineer SF330 submissions. Solicitation: 36C25522R0115 Construct Centralized Emergency Power System CONTRACT INFORMATION This A-E Services requirement is being procured in accordance with the Brooks Act (Public Law (PL0582) and implemented in accordance with the Federal Acquisition Regulation (FAR) Subpart 36. Firms will be selected for negotiation based on demonstrated competence and qualifications for the required work. This procurement is restricted to Service-Disabled Veteran Owned Small Business (SDVOSB) firms. This requirement is being procured in accordance with the VAAR 836.606-73 as implemented in FAR Subpart 36.6. This is not a Request for Proposal and an award will not be made with this announcement. This announcement is a request for SF 330 s from qualified architect-engineering firms that meet the professional requirements listed herein. The selection criteria for this acquisition will be in accordance with FAR 36.602-1 and VAAR 836.602-1 and are listed below in descending order of importance. The completed SF 330 will be evaluated by the Wichita VA Medical Center Evaluation Board in accordance with FAR 36.602-5(a) and the selection report shall serve as the final selection list, which will be provided directly to the Contracting Officer. The Government will not pay nor reimburse any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. The contract is anticipated to be awarded by January 30, 2023 Award of any resultant contract is contingent upon the availability of funds. No solicitation document is available and no other information pertaining to project scope, etc. is available at this time. Any request for assistance with submission or other procedural matters shall be submitted via email only to contact@example.gov and contact@example.gov. Hard copies shall not be accepted. Personal visits to discuss this announcement shall not be allowed. There will be no site visit by any architectural or consulting firm allowed. The NAICS Code for this procurement is 541330 - Architectural Services and the small business size standard of $22.5 million. Award of a Firm Fixed Price contract is anticipated. Anticipated time for completion of design is approximately 385 calendar days including time for VA reviews. DATABASE REGISTRATION INFORMATION: VERIFICATION OF STATUS OF THE OFFEROR SHALL BE ACCOMPLISHED BEFORE REVIEW OF SF 330. THIS ACQUISITION IS 100% SET-ASIDE FOR QUALIFIED SERVICE DISABLED VETERAN OWNED SMALL BUSINESS AE FIRMS INCOMPLIANCE WITH VAAR 852.219-10. ONLY BUSINESSES VERIFIED AND LISTED IN THE VENDOR INFORMATION PAGES DATABASE, (https://www.vetbiz.va.gov/vip), SHALL BE CONSIDERED. FIRMS NOT VERIFIED AT THE TIME OF RECEIPT OF THE SF 330 IN VETBIZ.GOV SHALL BE CONSIDERED NON-RESPONSIVE AND SHALL BE EXCLUDED FROM FURTHER CONSIDERATION. SYSTEM FOR AWARD MANAGEMENT (SAM): Federal Acquisition Registrations require that federal contractors register in the System for Award Management (SAM) database at https://sam.gov/content/ and enter all mandatory information into the system. Award cannot be made until the contractor has registered. Offerors shall be actively registered in SAM prior to submitting their qualifications package. Any firm not actively registered in SAM by the date of receipt of the SF 330 shall be considered non-responsive and shall be excluded from further consideration. THE EXCLUDED PARTIES LIST SYSTEM (EPLS): To ensure that the individuals providing services under the contract have not engaged in fraud or abuse regarding Sections 1128 and1128A of the Social Security Act regarding federal health care programs, the contractor is required to check the Excluded Parties List System (EPLS) located at https://sam.gov/content/ for each person providing services under this contract. Further the contractor is required to certify that all persons listed in the qualifications package have been compared against the EPLS list and are NOT listed. During the performance of this contract the Contractor is prohibited from using any individual or business listed on the List of Excluded Individuals/Entities. E-VERIFY SYSTEM: Companies awarded a contract with the federal government shall be required to enroll in E-Verify within 30 days of the contract award date. They shall also need to begin using the E-Verify system to confirm that all of their new hires and their employees directly working on federal contracts are authorized to legally work in the United States. E-Verify is an Internet-based system that allows an employer, using information reported on an employee's Form I-9, to determine the eligibility of that employee to work in the United States. There is no charge to employers to use E-Verify. (FAR 52.222-54) A-E firms are required to respond if interested by submitting one (1) completed Standard Form 330 qualification package Parts I and II to include all consultants (form available on-line at: http://www.gsa.gov/portal/forms/download/116486. Must include in Part I Section H an organizational chart of the firm (excludes consultants), information pertaining to a design quality management plan. Submission information incorporated by reference shall not be considered. All submissions shall be made electronically. Packages which are hand delivered or delivered via surface mail or any other method other than electronically shall not be reviewed. Completed package shall be delivered electronically on or before October 20, 2022 at 2:00PM Central Time to the NCO 15 Contracting Office, Attn: Sean Jackson or Jon Lutmer, Contracting Officers Contracting Office Address: 3450 S. 4th Street Trafficway, Leavenworth, Kansas 66048. contact@example.gov or contact@example.gov. Hard copies shall not be accepted. The email subject line shall clearly identify Solicitation number: 36C25522R0115 and Project 589A7-21-132 Construct Centralized Emergency Power System. The size of the pdf document must be below 20 MG. EVALUATION FACTORS: Selection criteria are in accordance with Federal Acquisition Regulation (FAR) Part 36.602-1 and VA Acquisition Regulation (VAAR) Part 836.602-1. Prospective firms are required to address all selection criteria within submitted SF 330 packages using additional pages as necessary. SF 330 submissions including any additional pages are not to exceed fifty (50) pages exclusive of table of contents, title page, and divider pages. Each side of a piece of paper is considered to be one page (i.e. Two pages to a single sheet of paper). Blank pages are not included in the count. Packages exceeding 50 pages shall be determined to be non-responsive and shall be excluded from consideration. Prospective firms are required to address all selection criteria within submitted SF 330 packages. Qualifications (SF330) submitted by each firm for Project 589A7-21-132 Construct Centralized Emergency Power System will be reviewed and evaluated based on the following evaluation criteria listed below: 1. Professional Qualifications: the qualifications of the individuals which will be used for these services will be examined for experience and education and their record of working together as a team. AE firms shall have professional architects, engineers, and consultants who are licensed in the United States of America. License information must be provided. The specific disciplines which will be evaluated are: Architects, Project Managers, Engineers (to include Energy Engineer, Civil, Electrical, Geo-Technical, Mechanical, Fire Protection, and Structural), LEED Consultants, and Estimators. 2. Specialized Experience and Technical Competence: specific experience and technical skill in the type and scope of work required for medical facilities, new construction, commercial kitchen construction, and renovations to existing medical facilities, including, where appropriate, experience in renovating space for patient privacy and rehabilitation services, energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Experience and qualifications of personnel proposed for assignment to the project and their record of working together as a team. 3. Capacity to Accomplish the Work: The general workload and staffing capacity of the design office which will be responsible for the majority of the design and the ability to accomplish the work in the required time will be evaluated. In accordance with VAAR 852.219-10(c)(1), prime contractors shall clearly demonstrate how they will meet the requirement that at least 50 percent of the design work be accomplished by employees of the concern or employees of eligible service-disabled veteran owned small business subcontractor/consultant. 4. Past performance: the past performance of projects that are complete (design and construction) that the firm has designed relevant in scope to the advertised project that were accomplished with the Department of Veterans Affairs, other Government agencies, and private industry in terms of cost control, quality of work, and compliance with performance schedules will be examined. Point of Contact information must be provided so past performance can be verified. Project past performances that are older than 3 years will receive a lesser score than those references for projects accomplished within the past 3 years. 5. Location of Design Firm: Per FAR 36.602-1 Selection Criteria: Given the responses to the Sources Sought notice, it has been determined that at least 3 qualified firms exist within a 500 mile radius of the Wichita VA Medical Center located at 5500 E. Kellogg, Wichita, Kansas 67218. Prime Architects responding to the request for SF330 s shall report the distance to the Prime contractor office. Architectural Prime Contractors outside of this 500 mile radius may be evaluated but will receive a lesser score. Firms may use Google Maps, Mapquest, Yahoo Maps, or Rand McNally to determine and report the distance of the office where the Prime Contractor is established. Prime contractor shall not use a subcontractor office, consultant office, or any office other than Prime Contractor s physical location established prior to publication of this notice to determine distance to the Wichita VA. 6. Claims and Terminations: record of significant claims against the firm or terminated contracts because of improper or incomplete architectural and engineering services will be examined. A/E SUPPLEMENT B TO SPECIAL PROVISIONS OF PROJECT 589A7-21-131 PROJECT NUMBER: 589A7-21-132 PROJECT TITLE: Construct Centralized Emergency Power System DESIGN TIME FRAME: A/E shall deliver final construction documents NLT 385 calendar days after the Notice to Proceed (NTP) Letter. CONSTRUCTION BUDGET/DESIGN LIMITATION: $22,335,000 CRITERIA FOR DESIGN AND PROJECT DEVELOPMENT (as applicable to project): Design Manual Reference PG-18-10 Design and Construction Procedures, PG-18-3 A/E Submission Instructions, PG-18-15, Minor and NRM Projects, Vol C Standard Details. Program Guide, PG-18-4 Equipment Guide List PG-18-5 Equipment Guide List Index Space Planning Criteria, PG-18-9 VA-Space and Equipment Planning System (VA-SEPS) Architectural Accessibility and VA Barrier Free Design Standards PG-18-13 Asbestos Abatement Design Manual VA Signage Design Guide Master Construction Specifications, Program Guide-18-1 VA Design Alerts VHA Fire Protection Design Manual VHA National BIM/CAD Standards Physical Security Design Manual for Mission Critical Facilities VA Sustainable Design Manual Infrastructure Standards for Telecommunications Spaces National Codes and Standards (NFPA, NEC, Natl. Plumbing Code, EPA, OSHA, Department of Veterans Affairs etc.) Robert J. Dole VAMC Limited-Scope Campus Utility Assessment dated Jun 17 2021 Note: Above documents can be found at the following website: http://www.cfm.va.gov/TIL/ SCOPE OF DESIGN/CONSTRUCTION PROJECT: A/E shall be required to provide all technical and engineering disciplines as needed to meet project requirements as outlined. It will consist of, but is not limited to, architectural engineering, civil engineering, mechanical engineering, structural engineering, electrical engineering, piping and plumbing, fire protection engineering, and a physical security consultant. A/E shall design in accordance with 52.236-22, Design Within Funding Limitation (APR 1984), the estimated construction contract price for this project is $22,335,000. If the project cannot be designed within funding limits specified, the A/E shall notify the Contracting Officer immediately in writing and shall not proceed further without direction from the Contracting Officer. A/E shall design a centralized emergency power system to back up the existing and planned site expansions for the Main Switchgears (MAIN 1 and MAIN 2) at N+1 and serve the legally required standby power needs for buildings on the Robert J. Dole VAMC campus. The existing generators by each building shall no longer be required and shall be removed. The design shall separate normal and emergency power underground to allow for maintenance on one system while the other is hot. This design shall expand main switchgear capacity. Existing MV Electrical Feeders from Main Switchgears to Selector Switches will need to be separated to comply with the VA Physical Security and Resiliency Design requirements. Work includes building service equipment associated with new system including generators, transformers, switchgear, automatic transfer switches, cabling, and associated building controls. Design shall include construction of a new 16,000 SF utility building to house new emergency generators and associated systems. The A/E shall make all site investigations necessary to thoroughly evaluate the area, including interviewing the staff impacted because of this project. Project will include but may not be limited to the necessary demolition and removal of existing concrete and buildings, drywall partitions; demolition and removal of existing; mechanical, underground piping, plumbing, lighting, fire protection, and electrical systems A/E will review VA furnished asbestos survey to identify known areas of remediation. The A/E shall conduct a study to supplement VA furnished survey to identify additional possible asbestos and/or lead contamination. The A/E will be responsible for all specifications and cost estimations associated with remediation required as part of the design period of services. Construction shall include the abatement of any hazardous materials as identified on the provided drawings. Construction contractor shall be responsible for third party air monitoring services to be provided during remediation of hazardous materials (i.e. asbestos, lead, mold, etc). Remediation shall be performed by the construction contractor. The construction of this project will take place in a very busy occupied building and is to be completed to allow medical care functions to be maintained uninterrupted throughout construction necessitating carefully phased construction and coordination with VA COR/users. The A/E shall make investigations necessary to thoroughly evaluate the area, including interviewing the staff impacted because of this project. All design shall be in accordance with A/E Submission Instructions for Minor and NRM Construction Program, Program Guide PG-18-15, Volume C, and all VA supplemental physical security directives. A/E shall work in collaboration with VHA staff and State Historic Preservation Organization, SHPO, to mitigate and come to agreeable terms for historic buildings on the campus for any construction that may disrupt or change the appearance of historic buildings in the historic registry. The A/E shall produce documentation that they will upload to the SHPO website that clearly states the agreed upon terms. The A/E shall apply for SHPO approval at their web site, https://www.kshs.org/shpo, then provide the Government documentation of application and SHPO approval letter prior to changes to buildings, building material or landscapes. A/E shall design to Guiding Principles Compliance and Validation requirements within VA Sustainable Design Manual. Project shall follow Internal Certification for NRM projects A/E to complete checklist and supporting documents and provide a copy to COR as well as email final check list to VA s Green Management Program (GMP) at contact@example.gov . Design multiple deductive bid alternates into the construction documents equal to at least 20% of the total construction cost (Design Limitation) not including contingency. The base design must be fully functional with or without the alternates. Provide an itemized cost estimate associated with each deduct alternate. Bid deduct alternates will reflect the appropriate reduction in project completion time (days). Each subsequent design submission shall incorporate all required changes/corrections from the previous set. A/E shall furnish summary of changes with comments on concurrence or reason change was not incorporated (i.e. code or VA requirements). SCOPE OF WORK FOR A/E: Design Development: The A/E shall make investigations necessary to thoroughly evaluate the area, including interviewing the staff impacted during construction. All design shall be in accordance with A/E Submission Instructions for NRM Construction Program, Program Guide PG-18-15, Volume C. Construction Document: After the VAMC approves the A/E's design development for construction documents, the A/E shall prepare construction documents necessary to accomplish the approved design development. Construction Period Service: The A/E shall perform design services as detailed within this document. Functional Product: The A/E shall perform design development, detailed design work, prepare detailed construction documents, keeping in mind the result shall be a completely functional fully operational product encompassing all unique processes of the facility to include but not limited to patient care, employees, visitors, equipment and security. The final design documents will be subject to review approval of the Integrated Project Team (IPT) consisting of medical center, and VHA personnel. These individuals will be identified by the COR at the first design review meeting. The A/E shall provide design in Revit or compatible software. The A/E shall complete design in accordance with VHA BIM and CAD standards. The A/E shall produce 2D CAD drawings from the model. The A/E will provide and maintain a secure FTP site that will be accessible to the VA staff assigned to the project. The site will be secure and only accessible with a username and password, to be provided by the A/E. This site shall be used throughout the duration of the project design and construction. A/E to provide web data services to VA specification for final construction and bidding documentation. Web service will have the ability to process, record, manage and exchange submittals from all parties involved in the submittal processes. Data exchange web site will provide services comparable to those provided by submittalexchange.com. Web service shall be accessible by VA computer systems and considered a secure site by the VA. A/E shall provide access to assigned staff, Contracting Officer, and contractors. Contractors shall have read and submission access only. The submittal data exchange system shall remain active through entire construction period. Once construction period is complete A/E shall provide one (1) CD copy of all submittal files.

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 236220
New
Federal
Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB
Solicitation # 36C25527Q0044
The Department of Veterans Affairs, Network Contracting Office 15, is conducting market research through a Sources Sought Notice to determine the availability of qualified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms for a construction project at the St. Louis Medical Center Jefferson Barracks. The project involves the replacement of the roof and associated components for Building 51, covering approximately 56,000 square feet. The scope includes installing a 70-mil thermoplastic polyolefin (TPO) roofing system, replacing four skylights, and updating the penthouse roof-access ladder to meet OSHA and VA safety standards. The estimated value of the resulting contract is between 2 million and 5 million dollars, with a required performance period of 222 calendar days from the Notice to Proceed. The project requires the contractor to manage work within an occupied 24/7 facility, necessitating a detailed phasing plan and strict adherence to infection control and HVAC-intake protection. Key technical requirements include providing a 20-year no-dollar-limit warranty, ensuring positive drainage to prevent standing water for more than 48 hours, and submitting as-built record drawings in searchable PDF and editable CAD formats. Interested firms must be registered in SAM.gov under NAICS code 236220 and provide a capability statement by November 9, 2026, including evidence of CVE certification, bonding capability, and a history of comparable work performed within the last five years.
Commercial and Institutional Building Construction

POSTED

about 8 hours ago

DEADLINE

in 11 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS