Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 1, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

C1DA-- AE-NRM-653-23-104 Electrical Study

Closed
36C26023Q0343Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
RFP #27-035 Hydraulic Modeling & system Analysis Program
Solicitation # 27-035
The City of Albany, Georgia, is soliciting competitive sealed proposals under RFP #27-035 for a qualified firm to develop and implement a comprehensive hydraulic modeling and system analysis program for its water distribution system. The primary objective is to create a fully functional model that the City can maintain internally for operations, planning, and emergency response without ongoing consultant reliance. The scope includes system analysis for pressures, fire flow, storage, pumping, outages, future growth, and capital improvement planning. To ensure platform independence, the final model must be delivered in its native software format as well as an EPANET-compatible format. Proposals must be submitted by 5:00 PM on November 23, 2026, to the Procurement Division in Albany, Georgia. Submissions must include one original and six copies on company letterhead, signed by an authorized official, and accompanied by a Certificate of Non-Collusion, a Governing Law and Venue form, and an Addendum Acknowledgement Form. Award will be based on a weighted evaluation of experience and qualifications (35%), project approach and understanding (30%), references and portfolio (25%), and a detailed fee proposal (10%). The selected contractor must maintain liability insurance of at least $1,000,000 per occurrence and $2,000,000 annual aggregate, as well as workers compensation and employers liability of at least $1,000,000. Compliance with the Georgia Security and Immigration Compliance Act and the Federal Work Authorization Program is required. Payment terms are Net 30, and the contract is subject to multi-year contract clauses pursuant to OCGA 36-60-13. All equipment provided must be the latest model and composed of new parts, with the City reserving the right to reject any materials that do not meet specifications.
City of Albany

POSTED

about 4 hours ago

DEADLINE

in 26 days
NAICS: 541330
New
SLED
ON-CALL STRUCTURAL ENGINEERING SERVICES
Solicitation # 26/27-15
The Town of Manchester, Connecticut, is soliciting proposals under solicitation number 26/27-15 for a qualified structural engineering firm to provide on-call services on an as-needed basis. The scope of work involves the review, analysis, inspection, and design of municipal infrastructure. To be eligible, the consultant must be a professional engineer licensed in the State of Connecticut. Proposals are due by October 29, 2026, and must be submitted electronically via the Town's procurement portal. The selection process is based on a points-based scoring method evaluating qualifications, relevant experience, key personnel, and hourly pricing, though the award is not based solely on cost. The Town reserves the right to shortlist candidates for interviews and negotiate with the selected vendor prior to the final award. Contractors must adhere to strict insurance requirements, including General Liability, Professional Liability, Cyber Risk, and Environmental Liability, each with minimums of 1,000,000 dollars. Additionally, the contract is subject to the Town of Manchester Living Wage Ordinance for values exceeding 25,000 dollars per fiscal year, requiring specific hourly wage rates for eligible employees and the submission of a Living Wage Certification. Required submission documents include a PDF proposal, a current IRS Form W-9, a SAM number, and a disclosure of any municipal litigation or arbitration from the past ten years. All services must comply with the laws of the Federal Government and the State of Connecticut.
Engineering

POSTED

about 5 hours ago

DEADLINE

in 8 days

General Info

NAICS

541330 - Engineering Services

Place of Performance

WA

Set-Aside

NONE

Documents

1

36C26023Q0343 - AE-NRM-653-23-104 Electrical Study

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Contacts1 person available
OfficeVANCOUVER, WA, 98661, USA
Office AddressVANCOUVER, WA, 98661, USA
Contacts
Helen WoodsContract Specialist

Full Description

Show more
DESCRIPTION This is a SOURCES SOUGHT NOTICE (36C26023Q00343) in support of the Department of Veteran Affairs Roseburg VA Medical Center in Roseburg, OR for market research purposes only to determine the availability of potential businesses with capabilities to provide the requirement described below. This notice shall not be construed as a request for proposal/request for quote or as any commitment or obligation on the part of the Government to issue a solicitation. The Government does not intend to award a contract on the basis of this request so proposals will not be considered. No reimbursement will be made for any costs associated with providing information in response to this synopsis or any follow-up information requests. Response is strictly voluntary- it is not mandatory to submit a response to this notice to participate in any formal solicitation process that may take place in the future. However, it should be noted that information gathered through this notice may significantly influence our acquisition strategy. Interested parties will be required to respond separately to any solicitations posted in the future as a result of this sources sought notice. Anticipated North American Industry Classification System (NAICS) code is 238210-Electrical Contractors and Other Wiring Installation Contractors. The largest a firm can be and still qualify as a small business for Federal Government programs is a size standard of $16.5M. Interested parties are invited to respond via e-mail to contact@example.gov. Responses will be used to determine the appropriate acquisition strategy. All responses due by 03/15/2023 at 12:00 Pacific Standard Time. Potential contractors shall provide, at a minimum, the following information (1-4): 1) Company name, address, and point of contact, phone number, e-mail address, and DUNS/EUID. 2) Is your firm eligible for participation in one of the following small business socio-economic programs? If so, please indicate the program. [ ] yes [ ] no Small Business (SB) [ ] yes [ ] no HUBZone [ ] yes [ ] no Small Business 8(a) [ ] yes [ ] no Small Disadvantaged Business (SDB) [ ] yes [ ] no Women-Owned (WO) Small Business [ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no Veteran Owned Small Business (VOSB) [ ] yes [ ] no Other (please specify) 3) What additional information would the Government need to provide for you to be able to submit an accurate and complete offer with full understanding of the requirements if we post a formal solicitation? 4) Provide a brief capability statement (Max 2 pages) with enough information to determine if your company can meet the requirement. The response must address key criteria: A. Provide the approach as how your company would perform complete testing and maintenance of the electrical distribution system throughout the Roseburg Veterans Administration Medical Center campus located in Roseburg, OR. B. Describe how the Electrical Engineer is a licensed professional engineer and has at least five years of experience in performing power system studies or demonstrate an equivalent level of proficiency in performing and interpreting power system studies. Within this description, please include the understanding and methodology of how the engineer would provide the engineering analysis, short circuit study, coordination study, and arc flash study in accordance with NFPA 70E and VHA Directive 1028 for the entire campus. C. Describe how the detailed test plan would encompass the proposed method of testing, sample test reports, proposed project schedule, and how coordination of shutdowns would occur. D. Describe if you think the draft scope of work s period of performance is or is not reasonable in your opinion, and if not, why. The Capabilities Statement for this sources sought is not expected to be a Request for Quotations, Request for Proposals or Invitation for Bids, nor does it restrict the Government to an ultimate acquisition approach, but rather the Government is requesting a short statement regarding the company s ability to provide the services outlined below. The capabilities will be evaluated solely for the purpose of determining to set-aside for the one of the socio-economic categories listed above or to conduct as an unrestricted procurement. Other than small businesses may respond to this notice in the event the market does not indicate small business interest. This synopsis is for information and planning purposes only and is not to be construed as a commitment by the Government. The Government will not pay for information solicited. Respondents will not be notified of the results. Note: Do not include Proprietary, classified, confidential, or sensitive information in responses. DESCRIPTION OF THE REQUIREMENT: The Department of Veterans Affairs is looking to obtain information on companies who are interested in the following project, Roseburg Electrical Study: The project will be two parts - part one is conducting the electrical study (survey) to ensure 100% compliance with VHA Directive 1028. Part two will be a firm fixed price maintenance work to test breakers and may include breaker replacement if a breaker fails. A partial draft scope of work is below for review. DRAFT SCOPE OF WORK: The purpose of this survey and maintenance work is to ensure 100% compliance with VHA Directive 1028 All work shall be accomplished in strict compliance with current editions of NFPA-70E, (Standard for Electrical Safety in the Workplace), NFPA-70B (Recommended Practice for Electrical Equipment Maintenance), ANSI-MTS (American National Standards Institute Maintenance Testing Specifications for electrical); and IEEE 242-2001, Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems. All survey work will be accomplished on energized equipment unless an outage is required due to specific equipment safety conditions. All maintenance and repairs will require an equipment outage. The electrical deficiency corrections shall be conducted by a team of licensed electricians under the authority of the lead Electrical Professional Engineer of the contractor. The contractor shall have replacement parts and equipment available. Repairs will consist predominantly of circuit breaker panel replacement and possible circuit breaker panel replacement (all new panels are to receive double hinged doors). The contractor shall prepare complete Short Circuit and Coordination studies including voltage drop calculations on the entire electrical system/s (both normal and emergency). The study shall begin at the incoming utility electrical service (for the normal system) and at the emergency generators (for the emergency system) and continue through to each branch circuit panelboard, motor control center or motor control panel in each building. The study shall include a system one-line diagram; Short Circuit and ground fault analysis, protective coordination plots, voltage drop calculations. Deliverables: 60% submission SHALL include: Letter from local electric utility provider (Pacific Power) indicating the available fault current at the point of service. Executive Summary. Minutes of the Entrance Briefing to include VHA Directive 1028 and Compliance Survey. Analysis and calculations for the Primary Distribution System and partial Secondary Distribution System for each building including switchgear, switchboard, and distribution panel, etc. The analysis shall include Short Circuit Study and Protective Device Coordination Curves. The analysis shall be based on the actual device data (including but not limited to fuses, breakers, and relays). 90% submission SHALL include: All Content from 60% submittal (including updates below) Deficiencies report and cost estimates. All comments from 60% submission with annotations and responses. All items identified in Para. 5, Specific Scope, as a separate Tab or Section to include: Full Campus SKM and Traditional One-Line Diagrams Note equipment not in service Grounding Analysis Short Circuit Study Hazard-Risk Table Coordination Curves Voltage Drop Calculations Emergency Power Analysis Recommendations Protective Device Settings Excel spread sheet for devices that require adjustments Cost Estimates Facility Condition Assessment (FCA) Excel spreadsheet Deficiency Report Cost Estimate Excel spread sheet MS Project outage schedule for testing and maintenance Completed analysis and calculations for the entire Primary and Secondary Distribution. Completed one-line diagrams. Each building on the Building List that is attached to the Scope of Work shall be identified on the diagrams. For Final Submission, provide two digital copies (compact disc) of the electrical system study (including data files). One original document of Final Submission shall be sent to the COR at the VAMC and shall include: A completed Report, including all corrected data from the 60% and 90% submittals and the coordination curves shall be in color. The completed report shall include an Executive Summary directed to the Medical Center Director or designee that includes a prioritized overview of the deficiencies found and the potential consequences if such deficiencies are not corrected. Responses to the 60% and 90% submission comments from the VAMC Peer Review including annotations and response. Digital copy (CD) of the entire report including all SKM data, AutoCAD, Word, Excel files and PDF. Color photos that show devices listed on the deficiency report. Arc Flash Hazard Warning labels compliant with requirements of latest NFPA 70E edition. NOTE: Arc Flash Hazard Warning labels need only to be provided to the VAMC. Provide final report with stamp and signature by a Licensed Professional Electrical Engineer. Period of Performance: 238 days Qualifications: The short-circuit, protective device coordination and arc flash hazard analysis studies shall be conducted under the supervision and approval of a Registered Professional Electrical Engineer skilled in performing and interpreting the power system studies. The Registered Professional Electrical Engineer shall have a minimum of five (5) years of experience in performing power system studies or a proven equivalent level of proficiency. The Contractor or approved engineering firm shall demonstrate experience with Arc Flash Hazard Analysis by submitting names of actual arc flash hazard analysis it has performed in the past. The lead electrician contractor must hold a level three (3) or higher electrical testing certification with five (5) years of experience performing medium voltage repairs and maintenance. The certification shall be in accordance with ANSI/NETA ETT, Standard for Certification of Electrical Testing Technicians.

More opportunities from Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)

Same awarding agency

NAICS: 238220
New
Federal
J041--White City B249 SE HVAC Repair
Solicitation # 36C26027Q0102
Solicitation 36C26027Q0102 is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) issued by the Department of Veterans Affairs. The contract requires the repair of a Mitsubishi R-410A comfort-cooling system (Serial 07W0090) located on the southeast side of Building B249 at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The scope of work includes leak detection, brazing repairs with nitrogen purge, refrigerant recovery, evacuation to less than 500 microns, and recharging the system to nameplate requirements. The contractor must provide a detailed service report documenting the root cause, repair actions, and compliance with EPA Section 608 and VHA ICRA/PCRA controls for occupied healthcare facilities. The period of performance is 30 calendar days from the Notice to Proceed. Award will be granted to the responsible offeror whose proposal is most advantageous to the government, considering price and other specified factors. Key regulatory requirements include adherence to OSHA 29 CFR 1910.147 for lockout/tagout and 29 CFR 1910.333 for electrical safety. Payments will be processed via Electronic Funds Transfer, and invoices must be submitted electronically through the Tungsten Network. Offerors must provide their Unique Entity Identifier and maintain firm pricing for 60 calendar days from the response deadline of November 10, 2026.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 9 hours ago

DEADLINE

in 13 days
View Details
NAICS: 334513
New
Federal
Boiler Plant O2 Sensor Replacement
Solicitation # 36C26027Q0101
The Department of Veterans Affairs, through the Network Contract Office 20, is conducting market research via a Sources Sought Notice for a firm-fixed price service contract to perform inspection, testing, maintenance, and repair of three model 6888 Rosemount flue gas analyzers. The work will be performed at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The primary scope involves replacing internal O2 analyzer components using original equipment manufacturer parts, specifically 18 inch standard cells, 18 inch heater strut assemblies, Hastelloy with Vee Deflectors for service up to 1300 degrees Fahrenheit, and new flange gaskets. The period of performance is six months, with on-site work required during core hours of 7:00 AM to 4:00 PM, Monday through Friday. This opportunity is designated as a total Small Business Set Aside under NAICS code 334513, with a size standard of no more than 750 employees. Qualified sources, including SDVOSB and VOSB entities, must provide company details, SAM.gov UEI numbers, and proof of manufacturer authorization if they are not the OEM. Contractors must employ qualified personnel, maintain general third-party liability insurance per FAR 52.228-5, and adhere to NEC, OSHA, and JCAHO standards. Deliverables include written daily reports to the Deputy Chief Facilities Management and testing documentation provided to the Contracting Officer's Representative. Interested parties are requested to provide a courtesy quote and capability statement to assist the government in evaluating price reasonableness and market availability.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

1 day ago

DEADLINE

in 6 days
View Details
NAICS: 325998
New
Federal
Microbiological media purchase order for Clinical Microbiology laboratory.
Solicitation # 36C26027Q0104
The Department of Veterans Affairs Network Contracting Office 20 is seeking sources for a microbiology testing media purchase order to support the Seattle Division of the VA Puget Sound Medical Center. This requirement covers a wide range of critical supplies for identifying pathogenic organisms in veteran patients, including long shelf-life products like Oxidase and Indole, perishable selective agar, biochemical test kits, and ATCC organisms mandated by the College of American Pathologists for quality control. The contract is structured with a base year running from February 1, 2027, to January 31, 2028, followed by four subsequent one-year option periods ending January 31, 2032. Deliveries are to be made to the Microbiology Lab in Seattle, with weekly shipments typically scheduled for Tuesdays and individual requests fulfilled as available. Due to the perishable nature of many items, the vendor must provide tracking information, and the cost of next-day delivery for all perishable goods must be included in the individual item price. All temperature-liable products require immediate refrigeration upon delivery. Invoicing is processed through the Austin Automated Payment System in Texas, and the vendor must provide SDS sheets for all media upon request. This sources-sought notice specifically looks for capable sources, including qualified SDVOSB/VOSB entities, with a response deadline of November 10, 2026.
All Other Miscellaneous Chemical Product and Preparation Manufacturing

POSTED

1 day ago

DEADLINE

in 13 days
View Details
NAICS: 238220
New
Federal
Z1DA--CON-NRM-668-22-106 Correct Domestic Water System
Solicitation # 36C26027R0014
Solicitation 36C26027R0014 is a negotiated request for proposals for the Department of Veterans Affairs to correct domestic water system deficiencies in Buildings 1 and 12 at the Mann-Grandstaff VA Medical Center in Spokane, Washington. The project is 100% set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 238220, with an estimated contract magnitude between $1 million and $2 million. The primary objective is to modify hot and cold potable water distribution systems to comply with VHA Directive 1061 for the prevention of scald injuries and Health Care-Associated Legionella Disease. The scope includes all labor, materials, and equipment, with a specific requirement to flush potable water dispensing fixtures twice weekly from installation until final acceptance. The period of performance is 275 calendar days from the Notice to Proceed. The government will utilize a Best Value tradeoff process for award, prioritizing technical experience and past performance over cost. Technical evaluations will favor offerors with demonstrated experience in phasing and Infection Control Risk Assessment (ICRA) within 24-hour operational emergency rooms. Proposals must be submitted in three separate volumes—Technical, Past Performance, and Price—by November 23, 2026. Awardees must provide performance and payment bonds, adhere to Davis-Bacon Act wage determinations, and comply with Buy American requirements. Additionally, the contractor must maintain strict confidentiality regarding sensitive information and provide a one-year warranty on all materials and installation.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in about 1 month
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS