CASCADE SCBA SYSTEM

Closed
W911S225U1548Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract involves the procurement and implementation of a Cascade SCBA system designed to meet rigorous safety and operational standards. The system must feature a NEMA 4 rated electrical enclosure with a UL-listed control panel, accompanied by comprehensive parts and repair manuals. It requires a maintenance indicator for the air inlet filter, a virus-free intake filtration system, and four ASME code-stamped air cylinders mounted in an integral rack. The system must incorporate a P5 B-Securus purification system, a minimum five-stage compressor powered by at least a 20 HP electric motor, and a PLC-based controller with a display screen of at least 6.75 inches. Safety features include an emergency stop push button, audible alarms, safety shutdowns for low oil pressure and high temperature, and an automatic condensate drain with a non-corrosive reservoir and shutdown indicator. Operational capabilities include the ability to fill three SCBA or scuba cylinders simultaneously, with a filling rate of at least 25 SCFM and a maximum pressure of 6000 PSI. The system must be powered by 208V three-phase power and include a CO/H2S monitoring system with audible alarms. It should be housed within a sound-attenuating enclosure with a turn latch and lift-off hinges for maintenance access. Additional safety features include NFPA 1901 2016 compliance for the containment fill station, which accommodates cylinders up to 31 inches, and a system of audible alarms with safety shutdowns to ensure user safety during operation. The contract is set aside for small businesses under the NAICS code 334519, with the Department of the Army as the contracting agency, located at Fort Drum, NY. The response deadline is August 20, 2025, and interested parties can contact James Ferraro via email or phone for further details.

General Info

Department of the Army solicits CASCADE SCBA system, small business set-aside, due Aug 20, 2025.

NAICS

334519 - Other Measuring and Controlling Device Manufacturing

Place of Performance

Deliver to address: James FerraroBLDG: 772: 6446-Indiana Ave.Fort Leonard Wood, MO. 65473, NY, 65473

Set-Aside

SBA

Documents

2

0001_W911S225U1548_S2P2_Brand_Name_or_Equal_Ferraro__James_A_CIV_USARMY_MSCOE__USA__2025_08_12_12_08_22__EST__1.pdf

PDF

W911S225U1548_S2P2_Brand_Name_or_Equal_Ferraro__James_A_CIV_USARMY_MSCOE__USA__2025_08_12_12_08_22__EST_.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QM Micc-Ft Drum
Contacts1 person available
OfficeFORT DRUM, NY, 13602-5220, USA
Office AddressFORT DRUM, NY, 13602-5220, USA

Full Description

Show more
Implemented Amendment only opened for a day pushed to 7 days. UNICUS IV:MUST HAVE A NEMA 4 RATED ELECTRICAL ENCLOSURE w/ UL LISTED CONTROL PANELMUST COME WITH PARTS AND REPAIR MANUALSMUST HAVE AIR INLET FILTER MAINTENANCE INDICATORMUST HAVE A VIRUS FREE INTAKE FILTERATION SYSTEMMUST HAVE (4) ASME CODE STAMPED AIR CYLINDERS INSTALLED IN AN INTEGRAL RACKMUST HAVE A P5 B-SECURUS PURIFICATION SYSTEMMUST BE AT LEAST A 5 STAGE COMPRESSOR MUST HAVE AT LEAST A 20 HP ELECTRIC MOTORMUST HAVE A PLC BASED CONTROLLER WITH AT LEAST A 6.75? SCREENMUST HAVE EMERGENCY STOP PUSH BUTTONMUST HAVE A NFPA 1901 2016 EDITION COMPLIANT 3 POSITION CONTAINMENT FILL STATION TO FIT SCBA OR SCUBA CYLINDERS UP TO 31?MUST HAVE CO/H2S MONITORING SYSTEM WITH AUDIBLE ALARMMUST BE ABLE TO FILL (3) SCBA OR SCUBA CYLINDERS SIMULTAINEOUSLY MUST BE 208V 3PHMUST BE CAPABLE OF PRODUCING 6000 PSIMUST HAVE A CHARGING RATE OF AT LEAST 25 SCFMMUST HAVE A SYSTEM OF AUDIBLE ALARMS WITH SAFETY SHUTDOWNSMUST HAVE COMPRESSOR LOW OIL PRESSURE AND HIGH TEMPERATURE SHUTDOWNSMUST HAVE AUTOMATIC CONDENSATE DRAIN SYSTEM WITH NON-CORROSIVE CONDENSATE RESERVOIR w/ INDICATOR TO SHUTDOWN WHEN FULLMUST HAVE SOUND ATTENUATING ENCLOSURE WITH TURN LATCH AND LIFT OFF TYPE HINGES

More opportunities from Department Of Defense → W6QM Micc-Ft Drum

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS