The contract involves the procurement of tracheal suction catheters and connectors designed for use in medical settings, specifically for tracheal anesthesia and aspiration during anesthesia. These devices feature a clear, pliable plastic tube with a nominal diameter of 18 French, a whistle-type tip with a maximum of two shaft eyes, and a finger valve connector. The catheters are compatible with various tubing sizes and can pass through different tracheal tubes and airways, with a recommended disposal period of 60 months. The items are issued individually and are part of a federal acquisition managed by the Department of Defense's Medical Supply Chain. The solicitation, identified by number SPE2DS-26-T-110N, requests 20 units with a delivery timeline of five days after order. The performance location is Annville, with the Department of Defense as the contracting agency. The contract includes several regulatory and quality requirements, such as adherence to technical standards listed in the DLA Master List, defense information protections, and specific packaging requirements. Bidders must specify the source and part number of their supplies when responding. Contact information for the primary point of contact, Zaylin Robinson, is provided for further coordination.
General Info
Agency
NAICS
Place of Performance
FORT INDIANTOWN GAP FTIG, ANNVILLE, PA, 17003-5003, USSet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
CATHETER AND CONNECTOR,SUCTION,TRACHEAL,,
TRACHEAL; SHAFT EYE QUANTITY 1; TIP TYPE WHISTLE;
CONNECTOR TYPE FINGER VALVE; CORE FABRICATION METHOD,,
NOT WOVEN; NOMINAL DIAMETER 18.000 FRENCH; CATHETER &
CONNECTOR SUCTION TRACHEAL E14 TB 18"FR PLAS STER DIS;
2 EYES MAX.; CLEAR PLIABLE TUBE,1 1/2 IN. (4 CM) LG;
WILL FIT VARIOUS SIZE TUBING AND PASS THROUGH ALL TYPES
OF TRACHEAL TUBES AND AIRWAYS; USED WITH TRACHEAL
ANESTHESIA SET; 6515-00-299-8687; FOR ASPIRATION DURING
ANESTHESIA; DESTROY AFTER 60 MONTHS; MATERIAL PLASTIC
OVERALL; STYLE DESIGNATOR TRACHEAL TUBE, CONNECTOR AND
ELBOW
UNIT OF ISSUE: EACH
..
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
..
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
..
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
..
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
..
BIDDER: PLEASE SPECIFY SOURCE AND PART
NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6515-01-497-0680 Quantity: 20 EA Purchase Request: 7016959196QTY: 10 Delivery: 5 days ADO