CATHETER, CHOLANGIOG
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The Kumar Catheter is a specialized medical device designed for laparoscopic cholangiography, featuring a 76 cm translucent tubing with a 16-gauge diameter and a 19-gauge, 1.25 cm needle at the terminus for precise puncture of Hartmann’s pouch in the gallbladder to enable biliary access or aspiration. The device is constructed to be used in conjunction with the Kumar Cholangiography Clamp and is explicitly latex-free, ensuring compatibility with patients who have latex sensitivities. It is supplied in a unit of issue consisting of twenty units per box, with the NSN 6515-01-729-6451 and a single box requested under purchase request number 7017746628. Delivery is required within 20 days after order placement. This procurement is governed by Federal acquisition regulations under solicitation SPE2DS-26-T-311R, issued by the Department of Defense through the Medical Supply Chain MD Surg FSF. Technical and quality specifications referenced in the document are defined by the DLA Master List of Technical and Quality Requirements, with compliance based on the version in effect as of the solicitation or award date. Packaging must meet DLA requirements, and government identification must be removed from non-accepted supplies. The contract is set to expire with bids due by August 11, 2026, with performance to take place at Fort Hood, Texas. Primary point of contact for inquiries is Michael Small, reachable via email and phone provided. Bidders are required to clearly specify their source and part number in response.
General Info
Agency
NAICS
Place of Performance
BLDG 36065, FORT HOOD, TX, 76544, USSet-Aside
Documents
(1)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
CATHETER,CHOLANGIOGRAPHY
THE KUMAR CATHETER , USED IN CONJUNCTION WITH KUMAR
CHOLANGIOGRAPHY CLAMP, IS MEANT TO PROVIDE A MEANS OF
LAPAROSCOPIC CHOLANGIOGRAPHY. IT COMPRISES A TRANSLUCENT
TUBING ( 76 CM. LENGTH AND 16 GA. ) THAT CARRIES A 19
GA., 1.25 CM LONG NEEDLE AT THE END. THE KUMAR CATHETER
IS USED TO PUNCTURE THE HARTMANN'S POUCH OF THE
GALLBLADDER FOR BILIARY ACCESS AND / OR ASPIRATION.
PRODUCT IS LATEX FREE.
UNIT OF ISSUE: BX/20 EACH
..
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
..
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
..
..
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
..
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
..
BIDDER: PLEASE SPECIFY SOURCE AND PART
NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6515-01-729-6451 Quantity: 1 BX Purchase Request: 7017746628QTY: 1 Delivery: 20 days ADO