This Solicitation opportunity from Department Of Defense was posted on May 31, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
CATHETER, INTRAVENOU
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The contract involves the procurement of intravenous catheters, specifically 20 gauge, 1.25 inches long Introcan Safety IV Catheters with a round Luer lock hub. These catheters feature a passive safety design that automatically engages a safety clip to prevent needle-stick injuries when the needle bevel exits the catheter hub. The product is made from FEP polytetrafluoroethylene and is available with or without wings, packaged sterile in boxes of 50, with a total quantity of 200 units per package. The item has a non-extendable shelf life of 60 months and must meet technical and quality standards as dictated by the Defense Logistics Agency (DLA) Master List of Technical and Quality Requirements. The solicitation is issued by the Medical Supply Chain MD Surg FSF under the Department of Defense, with performance location in Annville, ZIP code 17003-5003. The contract specifies a delivery timeline of 5 days after order date and requests bidders to specify the source and part number for their supply. The contract also enforces packaging, identification removal from non-accepted supplies, and data protection requirements relating to covered defense information. The primary point of contact is Michael Small, reachable via email and phone, and the solicitation response deadline is June 8, 2026.
General Info
Agency
NAICS
Place of Performance
FORT INDIANTOWN GAP FTIG, ANNVILLE, PA, 17003-5003, USSet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
CATHETER,INTRAVENOUS
INTRAVENOUS; ROUND; LUER LOCK HUB; 20.000 GAGE;
INTROCAN SAFETY IV CATHETER 20 GA 1.25 IN LG PLASTIC
200S; 1 1/4 INCH STRAIGHT NEEDLE, WITH PASSIVE SAFEY
DESIGN, PUSH OFF PLATE ON THE HUB, NEEDLE BEVEL
ORIENTATION INDICATED ON PUSH OFF PLATE, SAFETY CLIP
IS AUTOMATICALLY ENGAGED WHEN BEVEL EXITS THE CATHETER
HUB, AVAILABLE IN FEP POLYTETRAFLUOROETHYLENE, AVAILABLE
WITH AND WITHOUT WINGS, 4 BOXES OF 50 INTRAVENOUS
INJECTION; CATHETER, INTRAVENOUS, SAFETY; FEP INTROCAN
SAFETY IV CATHETER, STERILE
UNIT OF ISSUE: PG/200 EACH
..
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
..
RS023: Shelf-life requirement RS001 for a TYPE I (CODE S) item with a shelf life of 60 months (non-extendable) applies to this item.
..
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
..
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
..
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
..
BIDDER: PLEASE SPECIFY SOURCE AND PART
NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6515-01-488-5452 Quantity: 1 PG Purchase Request: 7016959260QTY: 1 Delivery: 5 days ADO