Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

CHIP, CHEMICAL, AMMONIA

Active
SPE2DH-26-T-6481Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This solicitation is for the procurement of a chemical ammonia measurement chip, identified by NSN 6640-01-497-5784. The chip features ten measurement capillaries with substance-specific reagent systems designed to measure ammonia in the range of 2.0 to 50.0 ppm. Each unit is calibrated during manufacturing and must have a shelf life of 24 months, with no more than four months elapsed from the date of manufacture to the date of delivery to the government. Packaging must adhere to commercial standards and Medical Marking Standard No. 1, ensuring each unit is in a sealed container to prevent damage. Labels must include the NSN, manufacturer and CAGE code, contract or lot number, and the dates of manufacture and expiration. The delivery requirement is five days after receipt of order, and the procurement is managed by the Department of Defense Medical Supply Chain.

General Info

Procurement of ammonia measurement chips NSN 6640-01-497-5784 for Department of Defense Medical Supply.

Agency

Department Of Defense → MEDICAL SUPPLY CHAIIN FSHView Agency

NAICS

333998 - All Other Miscellaneous General Purpose Machinery ManufacturingView NAICS

Place of Performance

601 DAVY CROCKETT RD, SAN ANTONIO, TX, 78226, USA

Set-Aside

NONE

Documents

(1)

SPE2DH-26-T-6481 RFQ

PDF20 pagesrfq

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → MEDICAL SUPPLY CHAIIN FSH
Contacts1 person available
OfficeUSA
Organization / Agency
Department Of Defense → MEDICAL SUPPLY CHAIIN FSH
View Agency Profile
Office AddressUSA

Full Description

Show more
CHIP,CHEMICAL,AMMONIA
CHIP, CHEMICAL
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
APPLICABLE TO ALL MEDICAL ACQUISITIONS:
PACKAGING AND PACKING SHALL BE COMMERCIAL AS
SPECIFIED IN THE PROCUREMENT DOCUMENT.
EACH COMPLETE UNIT SHALL BE PROPERLY PACKAGED
IN A SUITABLE SEALED UNIT CONTAINER CAPABLE
OF PROTECTING THE CONTENTS FROM DAMAGE AND/OR
BREAKAGE.
UNITS SHALL BE PACKED IN SUITABLE COMMERCIAL
EXTERIOR (SHIPPING) CONTAINERS (EXPORT WHEN
NECESSARY) WHICH SHALL INSURE ACCEPTANCE AND
SAFE DELIVERY BY COMMON OR OTHER CARRIER, AT
THE LOWEST RATE, TO POINT OF DELIVERY CALLED
FOR IN THE CONTRACT OR ORDER.
MATERIAL MUST BE MARKED IAW MEDICAL MARKING
STANDARD NO. 1. THIS SUPERCEDES ALL REFERENCES
TO MIL-STD-129.
COPIES OF MEDICAL MARKING STANDARD NO. 1
(MMS NO. 1) MAY BE OBTAINED BY CONTACTING DLA
TROOP SUPPORT VIA EMAIL TO fssb@dla.mil. MMS NO. 1 IS ALSO AVAILABLE ONLINE AT: https://www.dla.mil/Logistics-Operations/Packaging/
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
PROVIDES BEST RESULTS POSSIBLE CAPILLARIES
OF SEVERAL CHIPS HAVE MULTIPLE LEVELS TO HELP
ELIMINATE CROSS SENSITIVITY OR DERIVE A
SPECIFIC MEASUREMENT OF THE TARGETED CHEMICAL
CHIP CONSISTS OF 10 MEASUREMENT CAPILLARIES
FILLED WITH SUBSTANCE SPECIFIC REAGENT SYSTEMS;
GAS TYPE, PART NUMBER AND BATCH NUMBER ARE
PRINTED ON CHIP AND
BARCODE READ BY THE ANALYZER OPTICS
SPE2DH-26-T-6481
SECTION B
CONTAINS INFORMATION ABOUT GAS TYPE, MEASURING
RANGE AND MEASURING TIME REQUIRED FOR COMPLETING THE MEASUREMENT; EACH
CHIP IS CALIBRATED
DURING MANUFACTURING AND IS VALID FOR 2 YEARS;
AMMONIA, RANGE 2.0-50.0 PPM
.
END ITEM NSN 6640-01-497-5784
.
UNIT OF ISSUE:EACH (EA)
.
SHALL HAVE A SHELF LIFE OF 24 MONTHS.
NOT MORE THAN FOUR MONTHS SHALL HAVE ELAPSED FROM
DATE OF MANUFACTURE TO DATE OF DELIVERY TO THE
GOVERNMENT.
.
LABELS SHALL INCLUDE:
NSN
MANUFACTURER AND CAGE
DATE OF MANUFACTURE, EXPIRATION, OR RETEST DATE
CONTRACT NUMBER/LOT NUMBER
.
BIDDER: PLEASE SPECIFY SOURCE AND PART
NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6640-01-497-5789 Quantity: 1 EA Purchase Request: 7018158179QTY: 1 Delivery: 5 days ADO

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Defense → MEDICAL SUPPLY CHAIIN FSH

Same awarding agency