This subcontract for Closed-Loop Water Treatment and Analysis involves providing chemical water treatment services for closed-loop systems on Maryland Department of Juvenile Services facility projects. The contractor is responsible for preventing corrosion and organic growth by monitoring specific water chemistry parameters, including pH levels between 8.5 and 10.0, Total Dissolved Solids from 250 to 1700ppm, and Sodium Nitrite from 250 to 1500ppm. These tasks are performed using specialized water testing kits and chemical dosing equipment. The scope of work requires the delivery of monthly water chemistry analysis reports to ensure system stability. This opportunity falls under NAICS code 541380 and was posted on November 13, 2026, with a response deadline of December 4, 2026.

General Info

Agency

Maryland

Place of Performance

MD, USA

Set-Aside

NONE

Documents

This scope was carved out of BPM059704.

The full solicitation package (3 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

HVAC, BOiler Preventative Maintenance Repair and Water Treatment

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyMaryland
ContactsNo contacts available
OfficeN/A
Organization / Agency
Maryland
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Supplies and performs chemical water treatment for closed-loop systems for prime contractors on Maryland Department of Juvenile Services facility projects. Monitors pH levels (8.5–10.0), Total Dissolved Solids (250–1700ppm), and Sodium Nitrite (250–1500ppm) to prevent corrosion and organic growth. Uses water testing kits and chemical dosing equipment. Delivers monthly water chemistry analysis reports.

Similar Contracts

Same NAICS industry code

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS