Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Energy was posted on October 7, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

CO2 condensing unit

Closed
SLAC_349035_CO2CondensingUnitFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

Menlo Park, CA, 94025, USA

Set-Aside

NONE

Documents

3

Fixed Price Commercial Supplies and Services Subcontract Terms and Conditions Aug 2023

PDF, High priority: read this first9 pages · contract-document
High

Representations and Certifications Supplement - September 2022

PDF, High priority: read this firstreps-and-certs
High

Buy American Act Certification

PDF, Low priority1 page · certification
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

10 updates
PhaseClosed
Posted

Solicitation

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Sep 13, 2024 to Sep 20, 2024. The notice description changed.

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Sep 20, 2024 to Sep 28, 2024. The notice description changed.

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Sep 28, 2024 to Oct 12, 2024. The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Energy → Slac National Accel Labor -Doe Contractor
Contacts1 person available
OfficeMenlo Park, CA, 94025, USA
Office AddressMenlo Park, CA, 94025, USA
Contacts

Full Description

Show more
SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions. AMENDMENT 10 HI, The following Addendum is being issued for the subject Request for Quotation: 349035 CO2 Condensing Unit Revise previous statement in Amendment 9 to: A possible option that can be considered would two stages but single compressor. As far as concerning the question on the piping diagram , the temperature range of the CO2 would be +10,-35C, the minimum refrigeration capacity at -40C refrigerant evaporating temperature shall be 4kW The Carbon dioxide is entering the condenser at 50% vapor quality and needs to be fully condensed with -3 degC subcooling. This Addendum modifies the Request for Quotation and must be acknowledged. Failure to acknowledge all addenda could make your proposal non-responsive. Please confirm that the submitted proposal is not changed because of this addendum. If proposal sent is revised because of this, please submit the revised proposal. The following changes are hereby made to the appropriate documents contained the above-mentioned Request for Quotation (RFQ). All other terms and conditions of the RFQ remain the same. Thank you very much. Katherine Jill A. Coh SCM Commodities Team Lead SLAC National Accelerator Laboratory 2575 Sand Hill Road Menlo Park, CA 94025 Tel: +1 (555) 000-0000 Email: contact@example.gov AMENDMENT 09 HI, The following Addendum is being issued for the subject Request for Quotation: 349075 CO2 Condensing Unit ANSWERS TO QUESTIONS: We need to know the piping diagrams (where they will connect the CO2 pump) and min. and max. capacities in variable evaporating temperatures to design the unit. ANSWER: a cascade system with two compressors does not pass the cut of the critical requirements: mass and dimensions A possible option that can be considered would two stages but single compressor. As far as concerning the question on the piping diagram , the temperature range of the CO2 would be +10,-40C, the minimum refrigeration capacity at -40C shall be 4kW The Carbon dioxide is entering the condenser at 50% vapor quality and needs to be fully condensed with -3 degC subcooling This Addendum modifies the Request for Quotation and must be acknowledged. Failure to acknowledge all addenda could make your proposal non-responsive. Please confirm that the submitted proposal is not changed because of this addendum. If proposal sent is revised because of this, please submit the revised proposal. The following changes are hereby made to the appropriate documents contained the above-mentioned Request for Quotation (RFQ). All other terms and conditions of the RFQ remain the same. Thank you very much. Katherine Jill A. Coh SCM Commodities Team Lead SLAC National Accelerator Laboratory 2575 Sand Hill Road Menlo Park, CA 94025 Tel: +1 (555) 000-0000 Email: contact@example.gov AMENDMENT 08 HI, The following Addendum is being issued for the subject Request for Quotation: 349035 CO2 Condensing Unit ANSWERS TO QUESTIONS: The solicitation letter has the answers to all questions except the last one. Capacity Requirement: Please specify the required capacity for the application in question. 4000 W at -40 C evaporator temperature of the primary refrigerant. Suction Temperature: What is the recommended suction temperature range for optimal performance? It is a function of the selected refrigerant at the primary circuit and the design of the primary circuit. Voltage: Could you confirm the voltage specifications necessary for the application? It has specified at 460V 60 Hz three phases. Actual voltage could be +/-10% of the nominal voltage. Application: Lastly, we would appreciate any details regarding the specific application context in which these specifications will be utilized It is for camera/detector cooling. This Addendum modifies the Request for Quotation and must be acknowledged. Failure to acknowledge all addenda could make your proposal non-responsive. Please confirm that the submitted proposal is not changed because of this addendum. If proposal sent is revised because of this, please submit the revised proposal. The following changes are hereby made to the appropriate documents contained the above-mentioned Request for Quotation (RFQ). All other terms and conditions of the RFQ remain the same. Thank you very much. Katherine Jill A. Coh SCM Commodities Team Lead SLAC National Accelerator Laboratory 2575 Sand Hill Road Menlo Park, CA 94025 Tel: +1 (555) 000-0000 Email: contact@example.gov AMENDMENT 07 HI, The following Addendum is being issued for the subject Request for Quotation: 349035 CO2 Condensing Unit The bid close date is extended from September 27,2024 to October 11, 2024. This Addendum modifies the Request for Quotation and must be acknowledged. Failure to acknowledge all addenda could make your proposal non-responsive. Please confirm that the submitted proposal is not changed because of this addendum. If proposal sent is revised because of this, please submit the revised proposal. The following changes are hereby made to the appropriate documents contained the above-mentioned Request for Quotation (RFQ). All other terms and conditions of the RFQ remain the same. Thank you very much. Katherine Jill A. Coh SCM Commodities Team Lead SLAC National Accelerator Laboratory 2575 Sand Hill Road AMENDMENT 06 Hi, The following Addendum is being issued for the subject Request for Quotation: 349035 CO2 Condensing Unit Amendment to Technical Evaluation Criteria: SLAC is the process to build a refrigeration system to condense Carbon Dioxide by mean of a standard vapor compression refrigeration unit, working with any refrigerants approved by California Laws, ideally R448a The evaporator running with R448a or similar, must be a plate heat exchanger, condensing on the counter flowing side, a maximum flow of 30 g/s Carbon dioxide entering at .5 vapor quality. Because of the CO2, the pressures rating of the plate heat exchanger must 73 bar Amendment to Technical Evaluation criteria: Replace 5 with : - Condensing unit with vapor compression cycle running on R448a Replace 6 with: - Evaporator provided: Plate heat exchanger rated for 73 bar This Addendum modifies the Request for Quotation and must be acknowledged. Failure to acknowledge all addenda could make your proposal non-responsive. Please confirm that the submitted proposal is not changed because of this addendum. If proposal sent is revised because of this, please submit the revised proposal. The following changes are hereby made to the appropriate documents contained the above-mentioned Request for Quotation (RFQ). All other terms and conditions of the RFQ remain the same. Thank you very much. Katherine Jill A. Coh SCM Commodities Team Lead SLAC National Accelerator Laboratory 2575 Sand Hill Road Menlo Park, CA 94025 Tel: +1 (555) 000-0000 Email: contact@example.gov Amendment 05 HI, The following Addendum is being issued for the subject Request for Quotation: 349035 CO2 Condensing Unit The bid close date is extended from 9/19/2024 TO 9/27/2024 This Addendum modifies the Request for Quotation and must be acknowledged. Failure to acknowledge all addenda could make your proposal non-responsive. Please confirm that the submitted proposal is not changed because of this addendum. If proposal sent is revised because of this, please submit the revised proposal. The following changes are hereby made to the appropriate documents contained the above-mentioned Request for Quotation (RFQ). All other terms and conditions of the RFQ remain the same. Thank you very much. Katherine Jill A. Coh SCM Commodities Team Lead SLAC National Accelerator Laboratory 2575 Sand Hill Road Menlo Park, CA 94025 Tel: +1 (555) 000-0000 Email: contact@example.gov AMENDMENT 04 HI, The following Addendum is being issued for the subject Request for 349406 : CO2 Condensing Unit Answers to questions: Where are those rough estimates on size and weight or is there a plan to install the unit in a specific place where access or clearances are limited? Listed dimension and weight in the solicitation are; 48'x45'x62" and no Higher 1200lbs. ANSWERS: The dimensions is fixed. They can make the condensing unit to have a smaller footprint. The weight is the maximum. They can make the condensing unit lighter. This condensing unit is to be installed on a fixed frame (60'x60'x96). This Addendum modifies the Request for Quotation and must be acknowledged. Failure to acknowledge all addenda could make your proposal non-responsive. Please confirm that the submitted proposal is not changed because of this addendum. If proposal sent is revised because of this, please submit the revised proposal. The following changes are hereby made to the appropriate documents contained the above-mentioned Request for Quotation (RFQ). All other terms and conditions of the RFQ remain the same. Thank you very much. Katherine Jill A. Coh SCM Commodities Team Lead SLAC National Accelerator Laboratory 2575 Sand Hill Road Menlo Park, CA 94025 Tel: +1 (555) 000-0000 Email: contact@example.gov Amendment 03: Hi, The following Addendum is being issued for the subject Request for Quotation: 349035 Condensing Unit Bid close date will be extended from 9/12/2024 to 9/19/2024. This Addendum modifies the Request for Quotation and must be acknowledged. Failure to acknowledge all addenda could make your proposal non-responsive. Please confirm that the submitted proposal is not changed because of this addendum. If proposal sent is revised because of this, please submit the revised proposal. The following changes are hereby made to the appropriate documents contained the above-mentioned Request for Quotation (RFQ). All other terms and conditions of the RFQ remain the same. Thank you very much. Katherine Jill A. Coh SCM Commodities Team Lead SLAC National Accelerator Laboratory 2575 Sand Hill Road Menlo Park, CA 94025 Tel: +1 (555) 000-0000 Email: contact@example.gov Amendment 02: HI, The following Addendum is being issued for the subject Request for Quotation: 349035 CO2 Condensing Unit Answers to questions: We do not have a firm requirement on the cooling capacity at 10 C. Usually, the cooling capacity at 10 C is much higher than that at -40 C. If I need to set the capacity requirement, I will say 10,000 W. This Addendum modifies the Request for Quotation and must be acknowledged. Failure to acknowledge all addenda could make your proposal non-responsive. Please confirm that the submitted proposal is not changed because of this addendum. If proposal sent is revised because of this, please submit the revised proposal. The following changes are hereby made to the appropriate documents contained the above-mentioned Request for Quotation (RFQ). All other terms and conditions of the RFQ remain the same. Amendment 01 HI, The following Addendum is being issued for the subject Request for Quotation: 349035 CO2 Condensing Unit Answers to questions: (Batch 1) Pleased provide details on: Controls: timer / pressure controls / etc. Suction accumulator Oil separator Additional features / options Do you have any evaporator information included (provided by others) with this system? (brand / model / voltage /etc.) Answers: We are looking for a CO2 condensing unit. The CO2 condenser should have a minimum working pressure of 80 bar, or 1160 psig. The refrigeration circuit should have proper pressure control such as using a pressure switch or pressure relief valve. With regards to the refrigeration circuit, a suction accumulator is preferred. If the vendor uses an oil lubricated compressor, having proper oil separator is a must For Evaporator information included - SLAC cannot provide the brand/model/voltage- vendor has to provide this information in proposal. This Addendum modifies the Request for Quotation and must be acknowledged. Failure to acknowledge all addenda could make your proposal non-responsive. Please confirm that the submitted proposal is not changed because of this addendum. If proposal sent is revised because of this, please submit the revised proposal. The following changes are hereby made to the appropriate documents contained the above-mentioned Request for Quotation (RFQ). All other terms and conditions of the RFQ remain the same. Thank you very much. Katherine Jill A. Coh SCM Commodities Team Lead SLAC National Accelerator Laboratory 2575 Sand Hill Road Menlo Park, CA 94025 Tel: +1 (555) 000-0000 Email: contact@example.gov Hello, SLAC National Accelerator Laboratory has a requirement for the following item(s) listed below. 1.) CO2 condensing unit = Qty 1 Specifications: SLAC is in the process of building a prototype CO2 cooling plant. This CO2 cooling plant is to provide CO2 at subcooled state with CO2 flow rate ranging from 5 g/s to 30 g/s and temperature ranging from 10 C to -30 C. This CO2 condensing unit is to condense, cool down and maintain the CO2 flow at subcooled state. It utilizes a vapor refrigeration circuit to generate the cooling. The refrigerant should have an ASHRAE refrigeration classification of A1 (low toxicity and nonflammability) and is not listed at the Section 95374 - List of Prohibited Substances in CA. The power supply of the condensing unit is 460v/3ph/60hz. The condenser of the refrigeration circuit should be water cooled with cooling water inlet temperature at 17 C (63 F). The condensing unit should use expansion valve with adjustable cooling temperature and cooling capacity. The use of cylinder unloader and/or VFD to adjust the cooling capacity is recommended. When at full capacity, the condensing unit should give a cooling capacity of 4000 W with evaporator temperature at -40 C. The system weight should be less than 1200 lbs. The condensing unit should contain a CO2 condenser to condense and maintain CO2 fluid at the subcooled state. It should have a MAWP of 80 bar. Once the CO2 condensing unit deliver, the integration with the CO2 circuit (the CO2 pump, accumulator, flowmeter, and plumbing) will take place. The CO2 fluid and the CO2 pump is provided by SLAC. SLAC will take the ownership of integration of the CO2 condensing unit with the CO2 circuit at SLAC Technical evaluation criteria: Dimensions not higher than 48'x45'x62 Refrigeration Capacity 4kW at -40 Adjustable Evaporation temperature -40,+10 Water cool condenser with water inlet temperature at 63F Vapor compression cycle, no intermediate fluid CO2 condenser provided Weight of the unit less than 1200 lbs Optimized power consumption such as using cylinder unloader Quote is for product only; no on-site services permitted. Source selection will be based on Lowest Priced Technically Acceptable Method. Please provide a price and lead time quotation by COB September 12, 2024. Send quote to contact@example.gov. Please be advised that the requirement was also posted in SAM.gov. Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions? Buy American Act Certification (BAA) applies to awards over $10,000. Representations & Certifications Rider is required. Once completed the Reps and Certs is valid for one year until renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return. All subcontractors are required to register in the System for Award Management (www.sam.gov). If possible, please provide a link to your webpage for published price list to substantiate for the prices quoted. The resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and Conditions for Fixed Price Commercial Supplies and Services (Rev. August 2023) will be made a part of the resulting order. Please mark up terms and conditions if you wish to negotiate. No mark ups mean that you accept SLAC Terms and Conditions. Payment Terms will be NET-30 Freight terms will be FOB Destination Prepaid and Add You are requested to mark and identify proprietary/confidential information provided in response to the solicitation. Contact me directly with any questions. Sincerely, Katherine Jill A. Coh Procurement Commodities Team Lead SLAC National Accelerator Laboratory 2575 Sand Hill Road Menlo Park, CA 94025 Phone: +1 (555) 000-0000 Email: contact@example.gov

More opportunities from Department Of Energy → Slac National Accel Labor -Doe Contractor

Same awarding agency

NAICS: 334111
New
Federal
Supermicro 1U rack-mount server assemblies
Solicitation # SLAC_368659_Supermicro_1U_Rack-mount_Server_Assemblies
SLAC National Accelerator Laboratory, operated by Stanford University for the Department of Energy, is soliciting quotes for twelve Supermicro 1U rack-mount server assemblies, model AS-1115HS-TNR. Each server must be configured with one AMD EPYC Turin 9255 CPU, 64GB of DDR5 ECC memory (2x 32GB), and a Supermicro DCMS license. Storage options include either no drive or one 240GB SATA drive, and network requirements specify either a 10GbE 4-port RJ45 or a combination of 2x SFP+ and 2x RJ45. This is a product-only procurement with no on-site services permitted. Quotes must be submitted by October 16, 2026, to Cheryl Stafford. The resulting purchase order will be a fixed-price contract with NET-30 payment terms. Source selection will be based on the Lowest Priced Technically Acceptable method and the best lead time. Domestic shipments are FOB Destination Prepaid and Add, while foreign shipments are CIP SLAC, Menlo Park, Duty Unpaid. Offerors must be registered in the System for Award Management and provide a completed Representations and Certifications Rider. Additionally, proposals must include the Harmonized Tariff Schedule code and Export Control Classification Number where applicable. Buy American Act certification is required for unit prices exceeding 15,000 dollars. While not direct Federal procurements, these subcontracts incorporate various FAR and DEAR clauses depending on the final contract value.
Electronic Computer Manufacturing

POSTED

3 days ago

DEADLINE

in 4 days
View Details
NAICS: 334517
New
Federal
X-ray imaging detector system
Solicitation # SLAC_369006_Xray_Imaging_Detector_System
SLAC National Accelerator Laboratory, operated by Stanford University for the Department of Energy, is soliciting quotes for an X-ray imaging detector system. The required equipment includes one XRD 4343CT-F22-C-000 imaging grade digital X-ray detector, an XRD-EPS 215W power supply, and associated AC, DC, extension, and PC connection cables, along with an XRD FG(E) OPTO PCIe Frame Grabber V4. Technical requirements specify a flat-panel detector configuration with an amorphous silicon sensor, a minimum active area of 40 cm x 40 cm, a 150 micron pixel size, and applicability for hard and high-energy X-ray diffraction greater than 20 keV. This is a product-only procurement with no on-site services permitted. Quotes are due by October 16, 2026, and will be evaluated based on the Lowest Priced Technically Acceptable method and the best lead time. The resulting purchase order will be a fixed-price contract with NET-30 payment terms. Domestic shipments are FOB Destination Prepaid and Add, while foreign shipments are CIP SLAC, Menlo Park, Duty Unpaid. Offerors must be registered in the System for Award Management and provide a completed Representations and Certifications Rider. Additionally, proposals should include HTS Codes, ECCNs, and a statement regarding duties and tariffs. Buy American Act certification is required for unit prices exceeding 15,000 dollars. While not direct Federal procurements, these subcontracts incorporate various FAR and DEAR clauses based on contract value thresholds, including specific regulations regarding equal opportunity, whistleblower rights, and export controls.
Irradiation Apparatus Manufacturing

POSTED

6 days ago

DEADLINE

in 1 day
View Details
NAICS: 333248
Federal
BL18 In-Vacuum Undulator
Solicitation # 367893(RE)
SLAC National Accelerator Laboratory, operated by Stanford University for the Department of Energy, is soliciting proposals for the design, fabrication, assembly, tuning, and delivery of an In-Vacuum Undulator (IVU) for SSRL BL18. The project requires a U.S. domestic end item source to develop a system including a vacuum sub-system with entrance and exit taper sections, motion control, and a support frame. Technical specifications are governed by SSRL Engineering Note M927, with a reference design based on the BL17 IVU. Key technical requirements include a longitudinal envelope of 3798.3 plus or minus 2.0 mm and specific magnetic period counts depending on the magnet design. The proposal submission deadline is October 30, 2026, at 5:00 PM PDT, with all documentation directed to Ryan Enos. The requested delivery date is 19 months after receipt of order to align with an August 2028 installation window. Award will be based on the combination most advantageous to SLAC, utilizing a price/technical tradeoff and qualitative assessment of factors including past performance, technical design, and financial stability. Required submission documents include firm fixed pricing, a Quality Assurance Plan, a Dun and Bradstreet report, and various representation and certification supplements. Compliance with E-Verify and the Buy American Act is mandatory.
All Other Industrial Machinery Manufacturing

POSTED

23 days ago

DEADLINE

in 1 day
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS