Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, June 24 at 2:00 PM EDT

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on May 7, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Commercial Diesel Generator Set, 600kW Standby 60Hz

Closed
W911S226U3180Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

This contract involves the procurement of a commercial diesel generator set rated at 600kW for standby power at 60Hz frequency, designed to meet EPA Tier 2 emission standards and UL 2200 listing requirements. The unit features a 600DQCA diesel genset with a steel sound-attenuated Level 2 enclosure painted green, a horizontal cooling air outlet, and air inlet and outlet louvers with 24V DC spring-closed motors. The generator operates at 277/480 volts, 3-phase, wye-connected, and includes a 2400-gallon sub-base fuel tank compliant with UL142 and ULC S601, equipped with a high fuel fill alarm and dual stub-up connections. Additional components include a Power Command 2.3 controller with an English LCD display, a 1200A circuit breaker, a 12-amp regulated external battery charger, radiator cooling for 50°C ambient temperatures, a coolant heater for below 40°F conditions, fuel water separator, engine air cleaner, and a two-year base warranty. The contract, posted by the Department of Defense's W6QM Micc-ft Drum office located at Fort Drum, NY, is a total Small Business Administration (SBA) set-aside under NAICS code 335312. The solicitation number is W911S226U3180, with a response deadline of May 13, 2026. The contract includes compliance with FAR 19.5 for small business participation. The point of contact for inquiries is Carrie Lawton, with contact details provided. The genset is intended for stationary emergency use, meeting NSPS CI Stationary Emergency standards, and comes with an electronic OTEC transfer switch. The detailed specifications ensure robustness and reliability for critical standby power applications in military or government facilities.

General Info

Procurement of 600kW EPA Tier 2 diesel generator with fuel tank for emergency standby power, SBA set-aside.

Agency

Department Of Defense → W6QM Micc-Ft Drum

NAICS

335312 - Motor and Generator Manufacturing View NAICS

Place of Performance

4525 Camp Hale Rd Fort Drum, NY 13602, NY, 13602

Set-Aside

SBA

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

1 update
PhaseClosed
Posted

Combined Synopsis

Amendment 1

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QM Micc-Ft Drum
Contacts1 person available
OfficeFORT DRUM, NY, 13602-5220, USA
Organization / Agency
Department Of Defense → W6QM Micc-Ft Drum
Office AddressFORT DRUM, NY, 13602-5220, USA
Contacts
Carrie Lawton

Full Description

Show more
Amended to include set aside code. Characteristics:600DQCA, Diesel Genset, 60Hz, 600kW, Duty Rating - Standby Power (ESP), Emission Certification, EPA, Tier 2, NSPS CI Stationary Emergency, Listing- UL 2200, Voltage - 277/480, 3 Phase, Wye, 4 Wire, Alternator - 60Hz, Wye, 480 Volts,105C ? Standby, Alternator Heater, 120 Volt AC, Steel Sound Attenuated Level 2Enclosure, with Exhaust System, Enclosure Color - Green, Steel, Cooling Air Outlet -Horizontal, Sound Attenuated, Louvers - Air Inlet, 24 Volts DC Spring Closed, Motor Opened, Louvers - Air Outlet, 24 Volts DC Spring Closed, Motor Opened, Distribution Panel - Prewired AC Features, Fuel Tank - Sub Base, 2400 Gallon, UL142 Compliant, Listing, ULC - S601 ? 07, Alarm - High Fuel Fill, Fuel Tank Connection - Dual Stub Up,Fuel Water Separator, Control Mounting - Left Facing, Power Command 2.3 Controller, LCD Control Display, Stop Switch - Emergency, Externally Mounted, Signals - Auxiliary,8 Inputs/8 Outputs, Control Display Language ? English, Circuit Breaker or Entrance Boxor Terminal Box - Right Only, Terminal Box- Low Voltage, Left- None, Circuit Breaker -1200A, Right, 3P, UL 600, IEC 415, UL Serv Ent, 100%, Circuit Breaker or Entrance Boxor Terminal Box, Top Entry, Left- None, Bottom Entry, Right, Engine Air Cleaner - Normal Duty, External Battery Charger - 12 Amp, Regulated, Engine Cooling - Radiator, 50CAmbient, Shutdown - Low Coolant Level, Coolant Heater - 208/240/480 Volts AC, Below40F Ambient Temperature, Genset Warranty - 2 Years Base, Literature ? English, Packing -None, Base Mounted Housing, OTECD, OTEC Transfer Switch- Electronic Control: