This Solicitation opportunity from Department Of Defense was posted on April 29, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
CONTROL, BLOOD CHEMI
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The contract is for the procurement of CONTROL, BLOOD CHEMISTRY reagents specifically designed for use with the i-STAT PT Plus cartridge on the i-STAT system, with a total quantity of four boxes, each containing ten 1.0 mL units. These controls are intended for coagulation testing and must comply with stringent medical supply standards. Each unit must be packaged in a sealed container that protects against damage, with exterior shipping containers meeting commercial standards and ensuring safe, low-cost delivery via common carriers to Perry Point, MD, with FOB destination terms placing risk of loss on the government upon arrival. Packaging and labeling must adhere strictly to Medical Marking Standard No. 1 (MMS No. 1), superseding MIL-STD-129, and must include the date of manufacture, expiration or retest date, and contract or lot number. The product has a non-extendable 12-month shelf life from manufacture, with no more than one month elapsed between production and delivery to the government, and must be stored refrigerated at 2 to 8 degrees Celsius (36 to 46 degrees Fahrenheit) at all times—freezing is prohibited. Hazardous materials must be labeled according to 29 CFR 1910.1200, and any exempted materials must be explicitly identified. The supplier must provide the source and part number in bidding, and packaging must meet DLA’s RP001 requirements. The contract falls under NAICS code 325413, is issued by the Department of Defense through DLA Troop Support with a solicitation number SPE2DS-26-T-033M, and requires delivery within 20 days after award. Electronic submission through DIBBS is mandated, with responses due by May 5, 2026. Compliance with DFARS 252.204-7012 for safeguarding covered defense information is required, and all contractors must adhere to cybersecurity, whistleblower, and employment eligibility verification clauses specified in the FAR and DFARS. Invoicing must be performed via Wide Area WorkFlow (WAWF), and all supplies are subject to inspection and acceptance at the destination. Government identification markings must be removed from rejected items, and shipments cannot use parcel post. The contract has no stated value due to blank pricing fields, leaving unit price and total cost to be determined by competitive bidding.
General Info
Agency
NAICS
Place of Performance
BUILDING 5, PERRY POINT, MD, 21902, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
CONTROL,BLOOD CHEMISTRY
FEATURES PT PLUS CONTROL REAGENT LEVEL 2; FOR CONTROL OF COAGULATION
TESTING. FOR USE WITH I-STAT PT PLUS CARTRIDGE, TESTING PERFORMED ON THE
I-STAT SYSTEM; ANALYZER,BLOOD GAS, I-STAT 1 GOVERNMENT FIELD KIT.
UNIT OF ISSUE: BX (10/1.0ML EA PER BOX)
..
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
..
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
..
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
..
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
..
APPLICABLE TO ALL MEDICAL ACQUISITIONS:
PACKAGING AND PACKING SHALL BE COMMERCIAL AS
SPECIFIED IN THE PROCUREMENT DOCUMENT.
EACH COMPLETE UNIT SHALL BE PROPERLY PACKAGED
IN A SUITABLE SEALED UNIT CONTAINER CAPABLE
OF PROTECTING THE CONTENTS FROM DAMAGE AND/OR
BREAKAGE.
UNITS SHALL BE PACKED IN SUITABLE COMMERCIAL
EXTERIOR (SHIPPING) CONTAINERS (EXPORT WHEN
NECESSARY) WHICH SHALL INSURE ACCEPTANCE AND
SAFE DELIVERY BY COMMON OR OTHER CARRIER, AT
THE LOWEST RATE, TO POINT OF DELIVERY CALLED
FOR IN THE CONTRACT OR ORDER.
MATERIAL MUST BE MARKED IAW MEDICAL MARKING
STANDARD NO. 1. THIS SUPERCEDES ALL REFERENCES
TO MIL-STD-129.
COPIES OF MEDICAL MARKING STANDARD NO. 1
(MMS NO. 1) MAY BE OBTAINED BY CONTACTING DLA
TROOP SUPPORT VIA EMAIL TO fssb@dla.mil. MMS NO. 1 IS ALSO AVAILABLE ONLINE AT: https://www.dla.mil/Logistics-Operations/Packaging/
.. RS011: Shelf-life requirement RS001 for a TYPE I (CODE H) item with a
SPE2DS-26-T-033M
SECTION B
shelf life of 12 months (non-extendable) applies to this item.
SHALL HAVE A SHELF LIFE OF 12 MONTHS.
NOT MORE THAN 1 MONTH SHALL HAVE ELAPSED FROM
DATE OF MANUFACTURE TO DATE OF DELIVERY TO THE
GOVERNMENT.
.
SHELF LIFE MARKINGS SHALL BE IN ACCORDANCE WITH
THE LATEST REVISION OF MMS1C.
. ALL LABELS SHALL INCLUDE:
DATE OF MANUFACTURE, EXPIRATION, OR RETEST DATE
CONTRACT NUMBER/LOT NUMBER.
..
REQUIRES REFRIGERATION STORAGE BETWEEN 2 TO 8 DEGREES CELSIUS
(36 TO 46 DEGREES FAHRENHEIT) DO NOT FREEZE
..
BIDDER: PLEASE SPECIFY SOURCE AND PART
NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6550-01-725-6872 Quantity: 4 BX Purchase Request: 7016562593QTY: 4 Delivery: 20 days ADO
More opportunities from Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS