Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

Cooling and Recirculation System Supply

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Department of Commerce NIST is seeking a subcontractor for the Cooling and Recirculation System Supply project. The primary requirement is the provision of a closed-loop recirculating chiller unit designed to support the upper condensation cooling zone. The equipment must be capable of maintaining a coolant temperature of 20 degrees Celsius or lower, featuring a flow rate between 10 and 20 liters per minute and a reservoir capacity of 3 to 5 liters. This subcontract opportunity is categorized under NAICS code 333318 and will be performed in Gaithersburg, Maryland. The solicitation was posted on August 25, 2026, with a response deadline of September 4, 2026, at 5:00 PM.

General Info

NIST seeks a subcontractor for a closed-loop recirculating chiller in Gaithersburg, Maryland.

Agency

Department Of Commerce NistView Agency

NAICS

333318 - Other Commercial and Service Industry Machinery ManufacturingView NAICS

Place of Performance

Gaithersburg, MD, 20899, USA

Set-Aside

NONE

Documents

This scope was carved out of NB646050-26-02439.

The full solicitation package (1 document), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Short-Wave Infrared Radiation Open-Top Sample Digestion System

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Commerce Nist
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of Commerce Nist
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Supply a closed-loop recirculating chiller unit capable of maintaining coolant at ≤20°C with a flow rate of 10–20 L/min and reservoir capacity of 3–5 liters to support the upper condensation cooling zone.