Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity was posted on January 28, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

DRAGER V500 venilator and accessories

Closed
16-005528AFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Agency

N/A

NAICS

423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers

Place of Performance

10 CENTER DRIVE, BETHESDA, MD, 20892, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Milton DartoozosCONTRACT SPECIALIST

Full Description

Show more
THIS IS NOT A REQUEST FOR PROPOSALS (RFP) OR A REQUEST FOR QUOTATIONS (RFQ); NO CONTRACT WILL BE AWARDED PURSUANT TO THIS ANNOUNCEMENT. This synopsis is for information and planning purposes only and is not to be construed as a commitment by the government. This is NOT a Request for Proposal, Invitation for Bid, or an announcement of a solicitation. Response to this SOURCES SOUGHT is strictly voluntary and will not affect any firms' ability to submit an offer if a solicitation is released. There is no bid package or solicitation document associated with this announcement. The purpose of this document is to identify potential sources. Any requests for a solicitation package will be disregarded. The Government does not intend to award a contract on the basis of this source sought or otherwise pay for the information solicited. No entitlement to payment of direct or indirect costs or charges by the Government will arise as a result of preparing submissions in response to this sources sought and the Government's use of such information. Required Performance Capabilities: Information will be collected from Small or Large Manufactures and authorized distributors at this time to determine if the requirement can be met using a small business set-aside. All respondents are required to certify if they currently meet the small business requirements under the North American Industry Classification System (NAICS) code [423450], Medical, Dental, and Hospital Equipment and Supplies, as of the date of their submittal. BACKGROUND INFORMATION The Critical Care Medicine Department (CCMD) was established in November 1977 to provide medical care for critically ill patients throughout the Clinical Center who have potentially reversible medical problems. Critical care medicine may be defined as the observation, diagnosis, treatment, and rehabilitation of patients with overt or potential failure of vital functions. The Department is currently composed of the following sections: - Clinical Medical Services - Critical Care Therapy and Respiratory Care - Research Section - AIDS Section - Administrative Services The mission of the Department is to (a) provide superb care for Clinical Center patients who may benefit from critical care services, (b) improve both understanding and management of the critical disease processes, c) train health care professionals to understand, provide, and improve critical care services. The activities of the Department have been directed principally towards: - Organizing, developing and maintaining a medical facility capable of providing a full spectrum of superb critical care and specialized outpatient services to the Clinical Center. - Maintaining a consultative service to assist in the management and care of critically ill patients throughout the Clinical Center. - Maintaining an educational and training program in critical care for therapists, nursing and physician staffs. - Providing national leadership in directing the standards and goals of critical care clinical practice, training, and research. CCMD MISSION To provide high quality and cost effective clinical service that meets the needs of CC patients and NIH Institutes, to facilitate the research goals of NIH Institutes and investigators, and to conduct high quality research and training in Critical Care Medicine. PURPOSE The purpose for this SOW is for the purchase of a Drager V500 Ventilator from Drager. The Critical Care Medicine Department (CCMD) routinely performs emergency and post-operative ventilation procedures on adult and pediatric patients within the Clinical Center ICU. The Drager V500 allows for the ventilation of all patients regardless of size or age. The Drager V500 is currently able to interface to the Clinical Center electronic medical record using DataCapture to display patient parameters via the CDV. This equipment must match the existing equipment currently used in the Clinical Center in CCMD. Drager V500 Ventilator is utilizing our current system to interface with, rather than purchasing a ventilator that utilizes a different interface system. The Drager V500 provides customizable ventilation tools and functions. The customizable ventilation tools and functions are needed to support the complicated disease processes of Clinical Center patients. The Offeror shall provide the following: - (1 ea) #8416400-Workstation Critical Care - (1 ea) #OPC6592-Evita Infinity V500 PS500 and GS500 CS Hoses - (1 ea) #MK31500-Infinity Cockpit C500, M14.5, ID Expiration Valve, reusable - (1 ea) #OPC6041-V500 with nebulizer - (1 ea) #MS18782-System cable 0.7 m - (1 ea) #OPC6046-Prop. Pressure Support PPS - (1 ea) #OPC6048-Low-Flow PV Loop - (1 ea) #OPC6053-Non-Invasive Ventilation NIV - (1 ea) #OPC6136-Smart Pulmonary View - (1 ea) #OPC6145-PC-PSV - (1 ea) #OPC6050-SmartCare/PS - (1 ea) #OPC6052-CO2 monitoring - (1 ea) #OPC6042-Trolley - (1 ea) #OPC6043-Supp. frame Fairfield w/ bail - (1 ea) #G93110-Gas cylinder holder - (1 ea) #MP00690-Infinity ACS hinged arm - (1 ea) #MP02400-SelfTestLung - (1 ea) #8416347-USB flash drive Dr'ger - (1 ea) #4199592-O2 CS hose, 10 ft, DISS, Hand; DISS/CGAV-5 / Nipple+Nut Hand Length of CS hoses 10ft - (1 ea) #4199594-AIR CS hose 10ft DISS Hand; DISS/CGAV-5 / Nipple+Nut Hand Length of CS hoses 10ft - (1 ea) #1902241-V500 TotalCare 3Yr POS - (1 ea) #4119073-Adapter-DISS M/QC-O2-Ohmeda - (1 ea) #4119071-Adapter-DISS M/QC-AIR-Ohmeda - (1 ea) #6871980-Infinity ID Flow Sensor (5x) - (3 ea) #8416750-ID Expiration valve, reuse., V - (1 ea) #MP01008-Waterbag pole 900MR290 - (1 ea) #8411074-Mounting kit - (1 ea) #8416325-Humidifier holder, rail - (1 ea) #1979831-ICON Complete - (1 ea) #1979571-Clinical Applicat.SuppVentilat. 8h segm. CAPABILITY STATEMENT - Any potential Manufacturer must demonstrate the following: 1) The offeror shall submit product literature for the supplies it is proposing. Capability Statement(s) should clearly identify the following: a. Name of the Manufacturer, quantity and location where the units are produced (domestic and/or international); b. A signed statement to state, "We are the Manufacturer of the items and/or we are authorized distributors of company X"; c. Estimated Number of days, after receipt of order that is typical for delivery of such items; d. Any other relevant information that is not listed above which the Government should consider in developing its minimum specifications and finalizing its market research. 2) Provide the following business information: a. DUNS number b. Company Name c. Company Address (including point of contact, phone number and email address) d. Type/Size of company, NAICS code as validated in SAMS. Respondents will NOT be notified of the results of the evaluation. Responses must be submitted by email to POC, Milton.Dartoozos@nih.gov, within 15 calendar days (2/7/16) from the date of this synopsis.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS