Dry Chemical Fire Extinguishing System And Maintenance

Closed
MV448088Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management and Training Corporation is soliciting lump sum fee proposals for the clutch replacement of a Kubota M8200 tractor with front wheel assist, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires a qualified contractor to provide all transportation, labor, materials, and equipment to diagnose and repair the clutch assembly and power take-off system. Key technical requirements include replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as needed. The contractor must perform all work according to manufacturer specifications and provide a final summary of diagnostic findings, an itemized list of replaced parts, and warranty documentation upon completion. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Bids must be submitted via email to Angie Mahoney by 3:00 PM CST on November 3, 2026, and must include a bid sheet, proof of insurance, a completed supplier packet with a W-9, and applicable SBA certification letters. Award decisions will be based on best value, with a focus on administrative compliance and technical qualifications. The contract is subject to various Federal Acquisition Regulations, including standards for combating trafficking in persons, Buy American restrictions, and Service Contract Labor Standards per Wage Determination 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 2 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
ANNUAL ROTATING EQUIPMENT INSPECTION, TESTING, REPAIR, RECONDITIONING AND STORAGE SERVICES
Solicitation # 2026-RFP-130
Solicitation 2026-RFP-130, issued by the City of Lakeland, seeks qualified contractors to provide annual inspection, testing, repair, reconditioning, and storage services for critical rotating equipment at the McIntosh and Larsen Power Plants. The scope of work covers a wide range of industrial machinery, including low- and medium-voltage AC and DC electric motors, as well as circulating water and condensate pumps. Required services include clean inspect test (CIT) procedures, troubleshooting, motor rewinding, machining, welding, and dynamic field balancing. The contractor is also responsible for the pickup, transportation, and secure indoor storage of equipment, ensuring strict preservation measures such as periodic shaft rotation and moisture control to prevent corrosion and damage. The selection process is based on a points-based criteria to identify the vendor most responsive to the city's needs. Proposers must submit their responses via the OpenGov portal by October 30, 2026, and provide essential documentation including a signed W-9, Sunbiz registration, a notarized indemnification agreement, and a human trafficking affidavit. Contractors must adhere to strict safety standards, including OSHA compliance and specific certification for crane operations and critical lifts. Furthermore, vendors are required to maintain insurance policies with AM Best ratings of no less than A and must undergo a safety audit covering EMR and employee training records to ensure compliance with city risk management standards.
LE - Production - MPP

POSTED

about 5 hours ago

DEADLINE

in 8 days
NAICS: 811310
New
SLED
Overhaul Of Two (2) Boiler Feedwater Pumps, Motors & Valves
Solicitation # 5740
The City of Redding is soliciting proposals for the off-site shop inspection and overhaul of two Sulzer boiler feedwater pumps, two WEG motors, and two Fisher recirculation valves and their actuators. The scope of work includes the disassemble, clean, inspect, and overhaul (DCI) process, with the contractor managing all shipping, packaging, and handling of equipment to and from their facility. On-site services are limited to technical advisory supervision provided by Technical Field Advisors. A critical requirement is that the overhauled equipment must be returned to the power generation facility in Redding, California, within approximately 21 days of its initial removal and shipping. Award will be based on the best overall value, evaluated through a weighted system that prioritizes total project costs (30 points), contractor qualifications and experience (20 points), project approach and schedule conformance (20 points), understanding of project requirements (15 points), and proposal quality (5 points). The City is not required to award to the lowest cost proposer. Bidders must provide a bid security of 10%, along with payment and performance bonds of 100% and a maintenance bond of 50%. Proposals must be submitted by 3:00 p.m. PT on December 4, 2026, and must include a separate sealed envelope for the project costs and fee schedule. Because the services are off-site and professional in nature, prevailing wages under the California Labor Code are not required.
City of Redding

POSTED

about 9 hours ago

DEADLINE

in about 1 month

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Upton, NY, 11973, USA

Set-Aside

NONE

Documents

2

BNL Building 855 Dry Chemical Fire Extinguishing System 12-Year Maintenance SOW

DOCX, High priority: read this firstsow
High

Brookhaven National Laboratory Purchase Order BNLL-000448088

PDF, High priority: read this firstaward
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Energy → Brookhaven National Labor -Doe Contractor
Contacts1 person available
OfficeUpton, NY, 11973, USA
Office AddressUpton, NY, 11973, USA
Contacts
Malen Valencia

Full Description

Show more
Can you kindly quote the below into my name with the current date and lead time. Please offer BSA any discounts available for your Best Price. Items to be quoted: SEE ATTACHED SOW ~~ SEE ATTACHED DRAFT PO WITH QA CLAUSES~~ Line 1: 50 lb dry chemical cylinders Qty: 15 EA Line 2: SVA Actuators QTY: 15 EA Line 3: XV Control Heads QTY: 2 EA Line 4: Fusible links QTY: 46 EA Line 5: LABOR Please provide the following on your quote: 1. Origin of Manufacture 2. Unique Employee Identifier (EUI) Please also return the following along with your quote: 1. Published Price list: showing the items on your quote for price justification or a web screenshot (or link) of same/similar items with pricing and part number shown. 2. Insurance: **IF APPLICABLE** Upon award, in accordance with Article 6 of the attached - BSA Supplemental Terms and Conditions for Work by Contractors On Site at Brookhaven National Laboratory. Prior to coming on site to perform work, the certificate must remain in effect for the duration of the subject contract and must be filed with BNL Procurement & Property Management Division. Please Note: As Required by the Work on Site Terms - reference Article 6 - *Naming Brookhaven Science Associates and the US Government as additional insured along with all other requirements 3. System For Award Management (SAM): In order to support DOE reporting requirements, BSA requires all its vendors/contractors to be registered in the U. S. Government supplier database entitled System For Award Management (SAM). Registration can be performed on line at www.sam.gov. If not already registered, please register as soon as possible since failure to do so may preclude BSA from doing business with your organization. Please note that there is no charge for SAM registration. When registering, you are strongly urged to copy and paste www.sam.gov onto your browser address rather than utilizing your search engine. Utilizing your search engine may redirect you to an erroneous site. You may obtain assistance in completing your registration, free of charge, from the Association of Procurement Technical Assistance Centers (APTAC), or by contacting the Federal Help Desk at +1 (555) 000-0000. 4. Basis of Award: BSA will make award to the responsive and responsible offeror who submits the lowest total price and who meets all of BSA's technical requirements, as stated herein. 5. Pricing: shall remain valid for 60 days Quotations will be opened in private. Quotations, including their withdrawal or modification, received after the closing date shall be considered late. Such responses will only be considered for award if it is in BSA's best interest to do so. BNL anticipates a Firm Fixed Price Type contract. Any resulting purchase order will be subject to the attached terms and conditions.

More opportunities from Department Of Energy → Brookhaven National Labor -Doe Contractor

Same awarding agency

NAICS: 541330
New
Federal
A-E Services for Electron Injector Complex
Solicitation # RFP_476957
The Department of Energy, through Brookhaven National Laboratory, is soliciting proposals for Architecture and Engineering services for the Electron Injector Complex located in Upton, New York. This project involves the design and coordination of a multi-level facility featuring a 3,000 square foot first floor and a 5,000 square foot second floor. The scope of work includes the integration of mechanical, electrical, plumbing, and HVAC systems, specifically incorporating an internal hydraulic and pipe system based on MOCA specifications. Key deliverables include concept designs, infrastructure drawings, and ventilator load calculations, all of which must be coordinated with equipment plant drawings and safety requirements. The project mandates strict adherence to the 2011 ADA Standards for accessible design and requires that access control systems be cyber secured according to NIST 800 or ISA 62443 series standards. Quality assurance is governed by a specific plan covering design verification and configuration control, with inspection and acceptance processes managed by BNL Level 2 and Level 3 Managers using established BNL SBMS criteria. All equipment must be delivered new and in original packaging, with specific marking and labeling guidelines coordinated through HDR Architecture. The solicitation, identified as RFP 476957 under NAICS code 541330, has a response deadline of November 30, 2026.
Engineering Services

POSTED

about 6 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 334516
New
Federal
Optical Modulator (No Substitutions)
Solicitation # AB484554
Brookhaven Science Associates (BSA), acting for Brookhaven National Laboratory under a prime contract with the Department of Energy, is soliciting quotations for one 65GHz packaged TFLN intensity modulator (C-band, Low Vpi version, Cryo-compatible), part number TFLN-G2-IM-1550-65-V-LV. This is a firm fixed price procurement where the award will be based on the lowest total evaluated responsive and responsible offeror. Quotations must include the country of origin, Unique Entity Identifier (UEI), and a published price list if available. Pricing must remain valid for at least sixty days from the quotation due date, and all costs, including freight, must be incorporated into the item price as separate line items for additional charges will not be included in the resulting purchase order. The procurement is subject to various Federal Acquisition Regulation (FAR) clauses and BNL-specific quality assurance requirements, including BNL-QA-101 and ISO 9001 standards. Deliveries must be made to Brookhaven National Laboratory in Upton, New York, and must comply with ASTM Standard D 3951 for commercial packaging. Specific restrictions include a prohibition on the use of vermiculite unless required by regulation, in which case asbestos-free certification is required. Invoices should be submitted electronically in PDF format to the BNL Fiscal Division and must clearly reference PO# 484554, with final invoices explicitly marked as Final. Any measuring and test equipment used must be traceable to NIST or another recognized national standard.
Analytical Laboratory Instrument Manufacturing

POSTED

about 6 hours ago

DEADLINE

in 14 days
View Details
NAICS: 335999
New
Federal
HSR HF Dipole and Quad SC Magnet PS and Quench
Solicitation # APP00730MB
Brookhaven Science Associates, acting as the operator of Brookhaven National Laboratory, has issued a Request for Information and Sources Sought notice under solicitation APP00730MB for the design and manufacture of high-current power supply systems for the Electron-Ion Collider Hadron Storage Ring. The project requires the procurement of two modular units: Model A for the main arc dipole circuit and Model B for the main arc quadrupole circuit. These systems must include programmable PLC controls, current measurement and regulation equipment, quench-protection and control systems, and local operator interfaces. The selected contractor will be responsible for the full lifecycle of the equipment, including nonrecurring engineering, design, analysis, manufacture, inspection, testing, and delivery to the facility in Upton, New York. Technical requirements mandate compliance with ISO 9001 and BNL-QA-101 quality standards, as well as adherence to IEC, IEEE, NEC, and NEMA specifications. The contractor must perform initial testing at their own facility or a pre-approved site, with final acceptance occurring at Brookhaven National Laboratory within 90 days of receipt. Deliverables include a program plan, monthly progress reports, and a series of design reviews. Interested suppliers must submit their capabilities, estimated lead times, a compliance matrix, budgetary pricing, and any exceptions to the general terms and conditions to the contract specialist by December 11, 2026, at 5 PM EST.
All Other Miscellaneous Electrical Equipment and Component Manufacturing

POSTED

1 day ago

DEADLINE

in about 1 month
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS