Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Florida was posted on August 9, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Electrical Contractor (UPS Installation)

Closed
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency is soliciting proposals under RFP-VC-26-010 for professional transformer oil testing services to enhance the reliability, safety, and consistency of its transformer maintenance. The scope of work is divided into three primary areas: conducting visual and infrared thermographic inspections to identify thermal anomalies, installing standardized external oil sampling devices to improve technician safety, and performing detailed oil testing and analysis. Additionally, the selected contractor will evaluate nitrogen blanket systems to ensure positive pressure is maintained, provide on-site training for up to 20 agency staff members, and develop comprehensive standard operating procedures. All work must adhere to strict technical and safety standards, including ASNT Level 1 certification for thermography, ASTM D923 and D924 for oil sampling, and NFPA 70E safety protocols. The agency intends to make a single award based on the offeror's capability, staffing plan, personnel availability, and cost-effectiveness. Qualified candidates must demonstrate experience with at least one project for a utility or industrial facility and one project combining oil sampling with infrared inspections. Proposals must be submitted electronically via PlanetBids by December 23, 2026, and must include a detailed company profile, project methodology, and required certifications such as a Non-Collusion Statement and Workers Compensation Certificate. The resulting contract will utilize fixed pricing with a not-to-exceed total value and may include one-year extension options. Payment will be processed electronically via ACH within 30 days of invoice approval by the Project Manager.
Inland Empire Utilities Agency

POSTED

about 2 hours ago

DEADLINE

in about 2 months
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management and Training Corporation is soliciting bids for a fixed-price, single lump sum contract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project involves the inspection, repair, and certification of emergency lighting systems to ensure full compliance with NFPA 101 (2024 Edition), NFPA 70 (National Electrical Code), and OSHA safety regulations. The estimated contract value ranges between $25,000 and $100,000. Bids are due by December 1, 2026, and must be submitted via email to Sandra Clore. A mandatory physical site visit and signature on the attendance roster are required prior to bid submission. The award will be based on overall best value. Bidders must provide a detailed cost breakout on company letterhead and a bid bond guarantee of 20% for bids equal to or exceeding $25,000. Awarded contractors with bids at or above $25,000 must also provide performance and payment bonds from a surety company with at least an A- rating. The contractor is required to provide durable, uniquely numbered labels for all tested fixtures and deliver two complete operation and maintenance manuals, manufacturer warranties, and a one-year guarantee of workmanship upon substantial completion. Compliance requirements include adherence to the Davis-Bacon Act and Construction Wage Rate Requirements for Idaho, as well as FAR regulations regarding small business self-certification, debarment disclosure for subcontracts over $45,000, and the Buy American Act. Contractors must also comply with federal mandates for paid sick leave and the display of employee rights and wage determination notices. Final payment is contingent upon a joint substantial completion inspection and the resolution of all punch list items.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 2 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

This subcontract opportunity is for a Licensed Electrical Contractor to perform the installation and integration of UPS systems for prime contractors on City of Hialeah facility projects. The scope of work includes the physical installation of UPS units, battery strings, and paralleling equipment, with a specific focus on wiring for N+1 redundancy and the coordination of necessary inspections with the Fire Marshall to ensure a fully operational and wired system. Managed by the Emergency Operations Division in Florida, the project falls under NAICS code 238210. The solicitation was posted on August 9, 2026, and requires a response by September 10, 2026. Interested parties can find further details and submission guidelines through the City of Hialeah procurement portal.

General Info

Licensed electrical contractor needed for UPS system installation and integration in Hialeah, Florida.

Documents

This scope was carved out of 2025-26-029.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Emergency Operations Center, Standby Generator Phase 2: Parallel UPS Installation

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyFlorida → Emergency Operations Division
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Installs and integrates UPS systems for prime contractors on City of Hialeah facility projects. Performs physical installation of UPS units, battery strings, and paralleling equipment, including wiring for N+1 redundancy and coordination of inspections with the Fire Marshall. Requires a Licensed Electrical Contractor. Delivers a fully installed and wired UPS system.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS