This Solicitation opportunity from Department Of Homeland Security was posted on August 24, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

EMP/HEMP Protected Server Rack Cabinets

Closed
04316Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

33411

Place of Performance

VA, USA

Set-Aside

SBA

Documents

3

1.1.4+SOW+Server+Rack+Cabinets_Revised+7.16.21.doc

DOC

2.2+RFQ_Server+Racks_04316_sam.gov.doc

DOC

Questions+and+Answers.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

3 updates
PhaseClosed
Posted

special-notice

Notice updated

Response deadline time changed from 11:45 AM UTC to 1:00 PM UTC on Aug 11, 2021. The notice title changed. The notice description changed.

Notice updated

Notice type changed from Special Notice to Solicitation. Response deadline changed from Aug 11, 2021 to Aug 26, 2021. The notice title changed. Set-aside changed from Women-Owned Small Business to Total Small Business Set-Aside (FAR 19.5). The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → National Continuity SECTION(CON50)
Contacts1 person available
OfficeBERRYVILLE, VA, 22611, USA
Office AddressBERRYVILLE, VA, 22611, USA
Contacts
Tara Duckworth

Full Description

Show more
*Update (8/24/2021): A Questions and Answers document is now posted to this solicitation. The agency requires five (5) server rack cabinets protected with EMP / HEMP protection in the operation mode. One set per site should consist of (1) 20U Rack and (1) 10U Rack, cabinets should be lockable with internal airflow to keep equipment at operating temperatures. The power supply and cord will be determined after the equipment requirements and specs have been received by the vendor. Please provide a recommended period of performance for this effort and let the POC know if you have any questions. Deliverables: 1) Five (5) ea Server Rack Cabinet 2) Cabinet per set includes: 20U Rack and 10U Rack 3) Cabinets should be lockable with internal airflow to keep equipment at operating temperatures 4) Any applicable warranties for any part that is repaired and/or replaced Items to note: 1) The location for the placement of the racks is unknown and depends if there's a facility/office available. The worst case is remote/outside or even a facility with no air conditioning. 2) The equipment being used in the racks is typical network equipment, i.e. Cisco router, Cisco switch, UPS, Laptop and IDS. 3) Leave room for optional equipment. 4) Cable management is critical. 5) Standard entry/exit interfaces, i.e. Cisco router, Switch UPS, Laptop, IDS 6) Shielding levels, cutouts, connectors, seismic are Federal/DOD EMP/HEMP standards 7) Mounting rails to be tapped 8) Doors hinged right hand 9) MIL SPEC standards required 10) No casters however transportable wheels and handle 11) Line Filter, grounding bar, outlet strip, and chassis guides/supports required 12) The racks will be installed in open air office space without any constraints to airflow both incoming and exhaust. 13) The equipment being used in the racks and the amount of space needed for the equipment will determine the type of cooling needed for the rack. Customization may have to happen after award once the equipment to be used has been verified. 14) The equipment will also determine the size if the power filter needed for the rack, the filter needs to be mounted inside the protected space and the size of it along with the rack mounted equipment determine the depth of the rack. 15) Both power distribution and cable management system is required. 16) Power supply and cord will be determined after the equipment requirements and specs have been received by vendor. The power supply, airflow equipment, cable management etc. will be quoted separately after server equipment information is received by vendor.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS