Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

EPDM Membrane Roofing Installation

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This subcontract for EPDM Membrane Roofing Installation involves providing specialized roofing services for prime contractors on facility projects at the Commonwealth University of Pennsylvania. The scope of work includes the demolition of existing roofing materials, preparation of concrete decks, and the installation of a 90-mil EPDM membrane utilizing factory inseam and butyl splice tapes. To ensure a fully watertight system, the contractor will apply polyurethane-based resin flashing and synthetic-rubber polymer primers. The project is located in Columbia County, Pennsylvania, and falls under NAICS code 238160. Interested parties must submit their responses by the deadline of November 12, 2026.

General Info

EPDM membrane roofing installation at Commonwealth University of Pennsylvania, due November 12, 2026.

Place of Performance

Columbia County, PA, USA

Set-Aside

NONE

Documents

This scope was carved out of CWU-94-B.

The full solicitation package (4 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

CWU-94-B: Haas Roof Replacement Stage & North Side

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyPennsylvania → Columbia County
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Installs EPDM membrane roofing systems for prime contractors on Commonwealth University of PA facility projects. Performs demolition of existing roofing, prepares concrete decks, and installs 90-mil EPDM membrane using factory inseam tape and butyl splice tape. Applies synthetic-rubber polymer primers and polyurethane-based resin flashing. Delivers a completed, watertight roof system.

Similar Contracts

Same NAICS industry code

NAICS: 238160
New
International
PS-26-07
Solicitation # PS-26-07
Solicitation PS-26-07 is issued by the Regional District of Fraser-Fort George for the complete removal and replacement of the roof at 4030 Red Rock Road in Prince George, British Columbia. The project must be completed by August 31, 2027, with the contract term ending on August 15, 2027, or upon project completion. The Regional District will award the contract based on the best value offered rather than the lowest price, evaluating tenders on qualifications, past experience with similar projects, the proposed construction schedule, and the tender price. The contractor is required to provide all labor, materials, and supervision, ensuring work meets RCABC and CSA standards, including specific requirements for hot-dipped galvanized fasteners and asphalt shingle application. A ten-year manufacturer warranty is mandatory, and workers must be certified by the shingle manufacturer. Inspection services will be conducted by Aase Roof Inspection Ltd., with costs paid directly by the owner. The contract is governed by the laws of British Columbia and establishes an independent contractor relationship. Tenders must be submitted by November 17, 2026, at 2:00 p.m. Prince George Time, preferably as a single PDF file via email. Required documentation includes a tender form, schedule of prices, lists of personnel and subcontractors, experience records, a conflict of interest statement, and GST information. The successful contractor must also comply with the Workers Compensation Act and may be designated as the Prime Contractor to coordinate occupational health and safety. Payment will be made within thirty days of receipt of a valid invoice.
Regional District of Fraser-Fort George

POSTED

2 days ago

DEADLINE

in 30 days
View Details

More opportunities from Pennsylvania → Columbia County

Same awarding agency

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS