Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on May 16, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Ethernet Expansion Device (EED) V-22 Osprey

Closed
N00019223RFPREQAPM2750038Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing

Place of Performance

Latham, NY, 12110-2137, USA

Set-Aside

8A

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Naval Air Systems Command
Contacts2 people available
OfficePATUXENT RIVER, MD, 20670-5000, USA
Office AddressPATUXENT RIVER, MD, 20670-5000, USA
Contacts
Constance L. Humiston

Full Description

Show more
1.0 Introduction The Naval Air Systems Command (NAVAIR), Program Executive Office (PEO) Assault (A), V-22 Joint Program Office (PMA-275) is seeking sources for procurement of OnTime Networks, LLC Ethernet Expansion Device (EED) (PN: CR-6220F0-AER-SS02CLBN4-20-64-72) on all platforms of the V-22 aircraft. 2.0 Disclaimer THIS ANNOUNCEMENT CONSTITUTES A SOURCES SOUGHT NOTICE. THIS SOURCES SOUGHT IS ISSUED AS MARKET RESEARCH SOLELY FOR INFORMATION AND PLANNING PURPOSES - IT DOES NOT CONSTITUTE A REQUEST FOR PROPOSAL (RFP) OR A PROMISE TO ISSUE AN RFP IN THE FUTURE. THIS SOURCES SOUGHT DOES NOT COMMIT THE GOVERNMENT TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. THESE REQUIREMENTS ARE SUBJECT TO CHANGE AND THE INFORMATION PROVIDED BELOW IS FOR INFORMATIONAL PURPOSES ONLY. THE FINAL REQUIREMENT WILL BE DEFINED UNDER A FORMAL RFP. FURTHER, THE NAVY IS NOT AT THIS TIME SEEKING PROPOSALS AND WILL NOT ACCEPT UNSOLICITED PROPOSALS. RESPONDENTS ARE ADVISED THAT THE GOVERNMENT WILL NOT PAY FOR ANY INFORMATION OR ADMINISTRATIVE COSTS INCURRED IN RESPONSE TO THIS SOURCES SOUGHT NOTICE. ALL COSTS ASSOCIATED WITH RESPONDING TO THIS SOURCES SOUGHT WILL BE SOLELY AT THE EXPENSE OF THE INTERESTED PARTY. NOT RESPONDING TO THIS SOURCES SOUGHT DOES NOT PRECLUDE PARTICIPATION IN ANY FUTURE RFP, IF ISSUED. IF A SOLICITATION IS RELEASED, IT WILL BE SYNOPSIZED ON THE FEDERAL BUSINESS OPPORTUNITIES (FBO) WEBSITE. IT IS THE RESPONSIBILITY OF THE POTENTIAL OFFERORS TO MONITOR THIS WEBSITE FOR ADDITIONAL INFORMATION PERTAINING TO THIS REQUIREMENT. 3.0 Background The V-22 aircraft configuration includes the EED component manufactured by OnTime Networks, LLC. For improved affordability, the V-22 Joint Program Office (PMA-275) is soliciting information and comments from industry on its ability to provide a non-developmental or Commercial Off The Shelf (COTS) EED. The Government will consider responses for the purpose of determining whether to conduct a competitive procurement. The EED shall have the following capabilities: The Ethernet interconnection hardware shall operate on 28 VDC The Ethernet interconnection hardware SHALL have 20 Ethernet ports and 2 Serial ports. The Ethernet interconnection hardware SHALL contain both a Switch and a Router to enable the complex architecture and security of the Federated System network. The Ethernet interconnection hardware shall meet the temperature requirements of procedure I of test methods 501 and 502 of MIL-STD-810H using conditions specified in MIL-E-5400 for Class 1A equipment. The Ethernet interconnection hardware shall be capable of operating satisfactorily in all climates when subjected to an interior ambient atmosphere temperature between -40'C (- 40'F) and +71'C (+160'F). This is the required temperature range for equipment in the cockpit, cabin, and avionics racks. The Ethernet interconnection hardware shall be capable of withstanding thermal shock tests as stated in section 4.2.4.2.3.1 of the SD572: Temp Range -35C - +49C. The Ethernet Network Switch shall withstand the endurance vibration levels specified in the most current Government-approved revision of the V-22 vibration, Zone 2. The Ethernet interconnection hardware shall meet the shock requirements of test method 516, procedure I (functional shock), procedure V (crash hazard shock), and procedure VI (bench handling shock) of MIL-STD-810H. The classical saw tooth shock pulse of 11 ms duration shall be used. For functional shock, the Federated System Equipment shall be operating while 3 shock pulses of 20 g are applied in each axis direction (6 pulses per axis, 18 pulses total). A performance verification test shall be performed after functional shock. For crash hazard shock, the Federated System Equipment shall be unpowered while 2 shock pulses of 40 g are applied in each axis direction (4 pulses per axis, 12 pulses total). The bench shock number of drops shall be 24. The Ethernet interconnection hardware shall be designed such that all coatings and finishes shall withstand the cumulative exposure to salt fog expected over the life of the equipment IAW MIL-STD-810H. The Ethernet interconnection hardware shall be constructed so that dust (or fine sand) shall not be permitted to penetrate into cracks, crevices, bearings and joints to the extent that it interferes with the proper function of the equipment. The Ethernet interconnection hardware shall be designed such that no component or subassembly will cause detonation of an explosive mixture when operated for a sufficient time period to ensure thorough permeation of all accessible regions of the equipment. The Ethernet interconnection hardware shall meet the humidity requirements of test method 507 and Figure 507.5-7 of MIL-STD-810H at a relative humidity of 95 - 4% over ten temperature-humidity cycles. The Ethernet interconnection hardware shall meet the fungus requirements of test method 508 of MIL-STD-810H. The Ethernet interconnection hardware shall meet the rain requirements of procedure III of test method 506 of MIL-STD-810H. The Federated System Equipment, as installed and operating, shall meet Electromagnetic Environmental Effects control performance requirements (E3) of MIL-STD-464C and MIL Handbook 235. The electromagnetic performance of all subsystems listed in RTVM Appendix C, as installed and operating, shall operate together with all aircraft equipment without mutual interference or degradation of performance in accordance with MIL-STD-464C and MIL-STD-461G. The Ethernet interconnection hardware SHALL meet MIL-STD-461G Electromagnetic Interference Emissions and Susceptibility requirements for Naval systems, to include compliance with STANDARD LIMITS for Test Methods CS101. The Ethernet interconnection hardware SHALL meet MIL-STD-461G Electromagnetic Interference Emissions and Susceptibility requirements for Naval systems, to include compliance with STANDARD LIMITS for Test Methods CS115. The Ethernet interconnection hardware SHALL meet MIL-STD-461G Electromagnetic Interference Emissions and Susceptibility requirements for Naval systems, to include compliance with STANDARD LIMITS for Test Methods CE102. The Ethernet interconnection hardware SHALL meet MIL-STD-461G Electromagnetic Interference Emissions and Susceptibility requirements for Naval systems, to include compliance with CURVE #5 LIMITS for Test Method CS114. The Ethernet interconnection hardware SHALL meet MIL-STD-461G Electromagnetic Interference Emissions and Susceptibility requirements for Naval systems, to include compliance with Test Method CS116 NAVY 10 Amp requirement, and at 5.5 & 45 MHz platform RESONANCE frequencies. The Ethernet interconnection hardware SHALL meet MIL-STD-461G Electromagnetic Interference Emissions and Susceptibility requirements for Naval systems, to include compliance with NAVY HELICOPTER LIMITS for Test Method RE102. The Ethernet interconnection hardware SHALL meet MIL-STD-461G Electromagnetic Interference Emissions and Susceptibility requirements for Naval systems, to include compliance with NAVY EXTERNAL LIMITS for Test Method RS103. The Ethernet interconnection hardware SHALL meet MIL-STD-464C Electrical and electronic subsystems Electrostatic Discharge requirements utilizing MIL-STD-461G Test Method CS118. The Ethernet interconnection hardware SHALL meet the Lightning Protection requirements of MIL-STD-464C (Paragraph # 5.5) and MIL-STD-461G Test Method CS117. The Ethernet interconnection hardware shall withstand the following ultimate load factors (g): AxisApplied Separately Applied Simultaneously Longitudinal - 20'20'10'10 Vertical + 20 / -10+10 / -5+20 / -10+10 / -5 Lateral - 18'10'918." 4.0 Eligibility The applicable NAICS code is 336413 with a Small Business Size standard of 1,000 employees. The Product Service Code (PSC) is 1520. Businesses of all sizes are encouraged to respond; however, each respondent must clearly identify their business size (see paragraph 5.0). 5.0 Requested Information Section 1 of the response shall provide administrative information, and shall include the following as a minimum: Organization name, mailing address, overnight delivery address (if different from mailing address), phone number, fax number, and name and e-mail of designated contractual point of contact. Business type (large business, small business, small disadvantaged business, 8(a)-certified small disadvantaged business, HUB Zone small business, woman-owned small business, very small business, veteran-owned small business, service-disabled veteran-owned small business). Section 2 of the response shall provide technical information, and shall include the following as a minimum: Respondents should provide a detailed description of the following characteristics of their solution in their submission: Production lead time for each major component, ensuring items with the longest lead time are identified Unit Price List of existing Certifications and Standards Licenses and air time requirements Reliability Data/ Test Results (mean time between failure (MTBF) information and mean time between demand (MTBD) per component) Air Time Services (available providers, units, global coverage areas, describe plans) (if applicable) Projected end of life (EOL) date Minimum economic order quantity (if applicable) Total quantity of units sold to date Date of delivery of first unit Date of delivery of most recent unit Any available discounts Describe warranty options Built-In Test and Built-In Test Equipment (BIT/ BITE) (calibration/ measurement/ traceability) (if applicable) Describe training/ technical materials Provide a functional block diagram of the product/ system, describing all inputs and outputs of external systems Describe how each major component is to be mounted Provide a list of the recommended spare parts for each major component of the product/ system Provide screenshots of the key operational screens for the primary user device, with a brief explanation of each screen Describe the Operating/ Technical characteristics for each major component: Dimensions (height x width x depth) Weight, in pounds AC/DC power requirements (voltage/ current while in operation and stand-by modes) Batteries: types and estimated battery life (if applicable) Environmental protections/ military standard ratings (water resistance, electromagnetic interference (EMI) certifications, shock/ vibration certifications, overvoltage, overcurrent, airworthiness certifications, etc.) Operating and storage temperature limits (maximum and minimum) (Celsius) Humidity range limits, in Relative Humidity (RH) (operating & non-operating) Frequency Ranges (MHz) and RF output power for each frequency band (if applicable) Encryption/ decryption capabilities (if applicable) Identify the operating systems, if any, to include current revision information System test and diagnostic capabilities Input and output connector(s) descriptions OTAR capability Data at Rest capabilities (capacity, storage method, encryption capabilities, etc.) Airworthiness data including but not limited to; thermal, structural, electrical loads, vibration, etc. What category/categories of the ITAR's (Traffic in Arms Regulation) United States Munitions List (USML) and/or the EAR's (Export Administration Regulation) Commercial Control List (CCL) apply to the system/subsystem being purchased? If applicable and able, respondents shall include a list of Department of Defense (DoD), Department of Justice (DoJ) or Department of Homeland Security (DHS) programs of record that currently employ their solution. It would be helpful if a sponsor POC for each program, with email address and phone number could be identified. The Government is interested in receiving vendors price lists for items they believe meet the need in this RFI. Supplying price data does not imply a contractual obligation and must be provided and marked as PRICE DATA. 6.0 Responses Data Markings. In order to complete its review, NAVAIR must be able to share a respondent's information both within the Government and with covered Government support contractors as defined in DFARS clause 252.227-7013 Rights in Technical Data'Noncommercial Items (FEB 2014). Any responses marked in a manner that will not permit such review may be returned without being assessed or considered. All submissions must include a statement which clearly allows for the information to be disclosed with covered Government support contractors. International Traffic in Arms Regulations (ITAR). If the respondent is a foreign owned, controlled or influenced (FOCI) concern or if a US respondent has a team member or partner who is a foreign entity, adherence to all ITAR regulations is required. Full Response Submissions. Full response submissions to the above requested supporting data must be received no later than 4:00 PM Eastern Daylight Time (EDT) 26 May 2023 to the following address - Constance Humiston- constance.l.humiston.civ@us.navy.mil David Smithburger- david.m.smithburger.civ@us.navy.mil Christy Leach- Christy.l.leach.civ@us.navy.mil Provide full response via two hardcopies and two CD ROM with electronic media that is Microsoft Office 2010 compatible. It is requested that the response have a page limit of 25 pages, and must be in English. Classified information or material SHALL NOT be submitted. 7.0 Questions Questions regarding this sources sought can be directed to David Smithburger at david.m.smithburger.civ@us.navy.mil. 8.0 Summary THIS SOURCES SOUGHT IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. IT DOES NOT CONSTITUTE A SOLICITATION AND SHALL NOT BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT. RESPONSES IN ANY FORM ARE NOT OFFERS AND THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. NO FUNDS ARE AVAILABLE TO PAY FOR PREPARATION OF RESPONSES TO THIS ANNOUNCEMENT. ANY INFORMATION SUBMITTED BY RESPONDENTS TO THIS TECHNICAL DESCRIPTION IS STRICTLY VOLUNTARY.

More opportunities from Department Of Defense → Naval Air Systems Command

Same awarding agency

NAICS: 541330
New
Federal
PMA-290 Technical and Engineering Services
Solicitation # N0042125RFPREQAPM2900480-2
The Naval Air Warfare Center Aircraft Division and Naval Air Systems Command, supporting PMA-290, intend to award a sole source Single Award Indefinite Delivery Indefinite Quantity contract to Aviation Systems Engineering Company Inc. This effort, categorized under NAICS 541330, provides technical engineering and fleet deliverable capabilities for Maritime Patrol and Reconnaissance Aircraft and associated ground stations, specifically supporting the P-8A program. The scope includes systems engineering for new and modernized systems, software development and integration within a DEVSECOPS environment, cybersecurity, and the production of training materials. The contractor is also required to provide warehouse facilities for equipment storage and aircraft modification facilities near NAS Jacksonville, Florida. Performance is expected to begin in the third quarter of FY27, with work distributed across government sites in Patuxent River, Maryland; Seattle and Oak Harbor, Washington; Jacksonville, Florida; and Charleston, South Carolina, with approximately 20 percent of work performed at the contractor site. A critical requirement for this contract is adherence to the Navy Cybersecurity Workforce qualifications, with privileged access requiring specific IA certifications such as Security+ CE or SSCP. This notice is for informational purposes only and is not a formal request for proposal. Primary points of contact for this effort are Contracts Specialist Jacob Kerig and Procuring Contracting Officer Michele J. Estep.
Engineering Services

POSTED

about 7 hours ago

DEADLINE

in 14 days
View Details
NAICS: 51321
New
Federal
FortiNet FortiGate Software License Renewals
Solicitation # N00019-26-RFPREQ-APM290-0806
The Naval Air Systems Command (NAVAIR) is soliciting proposals for a Firm Fixed Price, Indefinite Quantity contract to procure FortiNet FortiGate software license renewals and subscriptions. This requirement specifically supports communications security for the P-8A Poseidon aircraft program, benefiting the United States Navy, the Royal Australian Air Force, and several Foreign Military Sales customers, including the United Kingdom, Norway, Republic of Korea, Canada, New Zealand, and Germany. The scope is strictly limited to FortiGuard Antivirus and Intrusion Prevention System subscriptions for FortiGate SX and BX modules, explicitly excluding FortiCare services, hardware support, or remote system access. The contract includes a base year running from February 1, 2027, through January 31, 2028, with four subsequent option years, for a total period of performance ending in January 2030. This is a limited competition open only to vendors listed on the Fortinet Federal Partners list; proposals from non-authorized resellers will not be considered. The acquisition is set aside for small businesses, including HUBZone, SDVOSB, and WOSB entities, with a HUBZone price evaluation preference applied. Award will be granted to the responsible offeror proposing the lowest total price for a minimum of 324 and a maximum of 1,378 units. Proposals must be submitted electronically via DoD Safe to the designated points of contact by October 28, 2026, at 4:00 PM. Invoicing and acceptance will be managed through the Wide Area WorkFlow system, with inspection and acceptance occurring at the destination in Patuxent River, Maryland.

POSTED

1 day ago

DEADLINE

in 8 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS