This Solicitation opportunity from Government of Canada was posted on July 27, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
EZ899-231976 Fire Alarm System Replacement, Telegraph Creek Detachment, British Columbia
Closed
WS3941792691CanadaSubmission Closed
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Agency
Government of Canada → Department of Public Works and Government ServicesView Agency
NAICS
N/A
Place of Performance
*Canada *British Columbia, CANSet-Aside
NONE
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
1 update
PhaseClosed
Submission Closed
Organization & Contact Information
Show more
AgencyGovernment of Canada → Department of Public Works and Government Services
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → Department of Public Works and Government Services
View Agency ProfileOffice AddressN/A
Contacts
Full Description
Show more
This bid solicitation cancels and supersedes previous bid solicitation dated 2023-03-29 with a closing of 2023-04-18 at 11:00am Pacific.
Work Description:
RCMP requires the replacement of the existing fire alarm system to new addressable type in RCMP detachment located at 5 Sawtooth Road, Telegraph Creek, British Columbia.General work to be performed: · Replacement of the existing fire alarm system with a new addressable system. This will include replacing of all existing fire alarm components with new and adding new devices where required and noted. · Provision of all work and material including conduit/wiring installation from telephone closet for connection of new fire alarm system to a 3rd party monitoring company as the existing fire alarm system is not monitored. · Existing conduit and wiring may be reused if the installation methodology and cabling types are appropriate for the new fire alarm system and meet the applicable codes. · New raceway and wiring installation to suit new devices. · Provision of fire watch to meet National Fire Code requirements at any time the building is occupied and the fire alarm system or part thereof is non-operational. · Detailed work plan including a project schedule and phasing prior to start of the work. · Provision of detailed shop drawings. · Provision of all close out documents including as-built drawings and operation and maintenance manual. · Provision of all required testing, verification and training services.