Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on July 2, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

F-16 Aircraft or larger painter module

Closed
F16AircraftPaintingModuleFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing

Place of Performance

JBSA Lackland, TX, 78236, USA

Set-Aside

NONE

Documents

1

Corrosion Control Facility Contract Requirements

PDF, High priority: read this firstsow
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W7N2 Uspfo Activity Txang 149
Contacts1 person available
OfficeLACKLAND AFB, TX, 78236-0123, USA
Office AddressLACKLAND AFB, TX, 78236-0123, USA
Contacts

Full Description

Show more
The requirements for the corrosion facility insert is as follows: The insert must comply with all of the requirements of the Aircraft Hangar Paint requirements of the Unified Facilities Criteria 4-211-02 dated 1 December 2012. The hangar will not be used for aircraft washes or media blasting. The insert should be able to fit an F-16 Aircraft or larger. The facility requires an air shower for egress of the insert. The system should be able to maintain facility temperatures and humidity requirements in accordance with Technical Order 1-1-8 paragraph 5.5.4. The system will be located in the San Antonio Climate. The Insert should fit within a hangar bay that is 73 11 5/8 wide, 73 4 deep and 140 Tall (see attached diagram). The door is a 3 part sliding door that is 61 3 Wide. The building has natural gas, electrical and water supplies available nearby. The questions we have are as follows: What is the largest aircraft that can be safely maintained in this area? What are the expected power requirements for this facility?

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS