Fairwood No. 2 Reservoir, Cedar River Water & Sewer District, Renton, WA
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The Fairwood No. 2 Reservoir project for the Cedar River Water & Sewer District in Renton, Washington, involves comprehensive structural and mechanical upgrades to the facility. Key scope of work includes expanding the foundation diameter to 98 feet and 1 inch to meet bearing pressure requirements, installing sixty 2-inch diameter anchors to prevent shell uplift, and applying a reservoir coating. Additional requirements include installing anchor bases, drain holes, sample lines, and anchor points, as well as replacing the roof vent, ladder, and guardrail. The project also necessitates the installation of new inlet/outlet piping and a manifold with duckbill valves, along with the relocation of the overflow pipe and catchment system. This solicitation, identified as BXWA-2026-002408, was posted on August 14, 2026, with a response deadline of August 25, 2026. A pre-bid meeting was scheduled for August 11 at the project site located at 16501 Parkside Way SE. David Matz, PE, serves as the primary point of contact for this local government agency project.
General Info
Agency
NAICS
Place of Performance
Renton, WA, 98058, USASet-Aside
Documents
(251)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Submission Closed
Organization & Contact Information
Interested Companies (17)
See All 17 Interested Companies
Start a free trial to view all interested companies, their contact details, and full contractor profiles.
Full Description
- Increase the outside diameter of the foundation to 98 feet and 1 inch (4 foot increase) to meet allowable bearing pressure
- Install sixty 2-inch diameter anchors to prevent shell uplift
- Install anchor bases around screen vent
- Reservoir Coating
- Add drain holes near base of guardrail posts
- New inlet/outlet piping, inlet manifold with duckbill valves
- Install anchor points at top of tank
- Install sample lines
- Install new roof vent, ladder, and guardrail
- Relocate overflow pipe outside of tank and associated catchment system
Pre-Bid Meeting: 8/11 @ 10:00 am at 16501 Parkside Way SE (project site)
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS