Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, June 24 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Government of Canada was posted on January 8, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Forestry and Parks - Request for Quotes - 20 foot x 8 foot Office (Modified Shipping Container or similar model)

Closed
AB-2026-00148Canada

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Government of Canada → Forestry and Parks

NAICS

N/A

Place of Performance

Alberta, CAN

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → Forestry and Parks
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → Forestry and Parks
Office AddressN/A
Contacts
FP PurchasingContracting Authority

Full Description

Show more
The Province is in need of a moveable Kiosk that would be used for the Park employees to greet visitors to the Park, process their reservations and provide information. Goods must meet or exceed the following specifications: (a) All Specifications and installations to Alberta Building Code; (b) 20 foot x 8 foot Office (Modified Shipping Container or similar model); (c) Staff Room for storage of personnel belongings and gear. The room should have a single door access with a 4 person locker and should take no more than 32 square feet; (d) 1 personnel Door on the 20 foot side. All doors must have locks and fire-proof rating of 45 minutes and a magnetic door stop; (e) 1 White Slider Window with heavy duty Frame is to be 6 foot W x 3 foot High on 20 foot side (by door) (f) 1 personnel door on the 8 foot side (opposite the staff room); (g) Air Conditioning and Heating with thermostats capable of cooling and heating the entire space; (h) Dry-wall Finishing walls and ceiling and insulated; (i) Vinyl Plank Floor; (j) Electrical to provide lighting as well as lighting fixtures and switches for the entire space (including outlets for AC and Heating and additional outlets for office use (not less than 4 sockets points); Include an external socket for power plug in, rated for building or power plant plug in; (k) Exterior color to be grasslands landscapes colors (greens, beiges, brown); and (l) Delivery.