Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Government of Canada was posted on September 28, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Fourier Transform Infrared FTIR Analyzer

Closed
23-58091International

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334516
New
Federal
Nitrogen Content Analysis Equipment
Solicitation # W911S227U0056
Solicitation W911S227U0056 is a Request for Quotation issued by the Department of Defense, specifically the W6QM Micc-Ft Drum, for the procurement of new nitrogen content analysis equipment. This acquisition is a Total Small Business Set-Aside under NAICS code 334516. The government is seeking a high-end titration system and associated accessories, specifically requesting Metrohm USA Inc products or equals. Key required items include a 905 Titrando high-end titrator, an 801 Stirrer, an 800 Dosino dosing system, a Touch Control 900, and standard installation services. Only new equipment is acceptable, as used or remanufactured products are strictly prohibited. The contract will be awarded to the responsible offeror whose proposal is most advantageous to the government based on price and technical evaluations. To be considered, offers of equal products must meet all salient physical, functional, and performance characteristics and include descriptive literature and model identification. Quotes must be submitted exclusively through the PIEE Solicitation module by October 29, 2026, and must include a completed Attachment 1 regarding certifications and country of origin to avoid being rejected as nonresponsive. Preferred delivery is F.O.B. destination within 30 days. Invoicing and payments will be processed electronically via Wide Area Workflow.
W6QM Micc-Ft Drum

POSTED

about 5 hours ago

DEADLINE

in about 24 hours
NAICS: 334516
New
Federal
NCSS - Bioruptor Pico Sonication Device
Solicitation # 75N98027Q00035
The National Institutes of Health Office of the Director, Office of Acquisitions, is issuing a non-competitive combined synopsis and solicitation under number 75N98027Q00035 to award a firm-fixed-price purchase order. The procurement is intended for Hologic Sales and Services, LLC to provide one Bioruptor Pico Sonication System and associated starter maintenance and consumable accessories for the National Heart, Lung, and Blood Institute Systems Biology Center. This equipment is essential for preparing chromatin for ChIP-seq and related epigenomic studies, requiring specific capabilities such as indirect sonication in closed tubes, an integrated cooling system, and the ability to process up to 12 samples of 0.65 mL or 6 samples of 1.5 mL per run. The acquisition includes the Bioruptor Pico system with an Essential Maintenance Starter Pack for one year of support, a tube holder and dock for 1.5 mL tubes, and various microtubes, along with no-charge installation and training. Delivery is required within 60 calendar days after receipt of order to Bethesda, Maryland. While this is a non-competitive notice of intent, all responsible sources may submit capability statements or quotations by November 10, 2026. Submissions must include the vendor's Unique Entity Identifier, Taxpayer Identification Number, business size certification, and proof of active registration in the System for Award Management.
National Institutes Of Health Olao

POSTED

about 5 hours ago

DEADLINE

in 13 days

AI Contract Overview

Show more

The National Research Council Canada intends to award a contract for one Fourier Transform Infrared Spectroscopy Analyzer to California Analytical Instruments, Inc. This equipment will be used at the Ottawa Montreal Road campus to sample and analyze concentrations of various species in heavy-duty internal combustion engine exhaust. The analyzer must meet strict technical specifications, including the ability to measure at least 40 gases simultaneously, a 10-meter stainless steel gas cell, and compatibility with existing laboratory data acquisition systems. The procurement includes a zero air generation system, a 25-foot heated sample line, a heated filter, and a Windows-based computer with perpetual license software. Because the pre-identified supplier is considered the only provider capable of meeting the technical requirements and ensuring system compatibility, the government is invoking specific exceptions to standard contracting regulations. Other qualified suppliers had until September 28, 2023, to submit a statement of capabilities to contest the sole-source award.

General Info

NRC Canada awards California Analytical Instruments a contract for an infrared spectroscopy analyzer.

Place of Performance

*Ontario (except NCR), CAN

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → Kacendra Dion
Contacts1 person available
OfficeN/A
Office AddressN/A
Contacts
Kacendra DionPoint of Contact

Full Description

Show more
Advance Contract Award Notice (ACAN) 23-58091 Fourier Transform Infrared FTIR Analyzer 1. Advance Contract Award Notice (ACAN): An ACAN is a public notice indicating to the supplier community that a department or agency intends to award a contract for goods, services or construction to a pre-identified supplier, thereby allowing other suppliers to signal their interest in bidding, by submitting a statement of capabilities. If no supplier submits a statement of capabilities that meets the requirements set out in the ACAN, on or before the closing date stated in the ACAN, the contracting officer may then proceed with the award to the pre-identified supplier. 2. Definition of the requirement: The National Research Council (NRC) Energy, Mining and Environment (EME) has a requirement to the supply of one (1) Fourier Transform Infrared (FTIR) Spectroscopy Analyzer (hereafter referred to as the “Analyzer”) suited for sampling and analyzing the concentration of certain species (detailed below) in the exhaust gas of heavy-duty internal combustion engines. The Analyzer will be used in the heavy-duty engine laboratory at NRC, Ottawa Montreal Road campus. The Analyzer must meet all of the mandatory technical requirements as specified below and must be compatible with the existing gas analysis and engine control system in the NRC laboratory. 3. Criteria for assessment of the Statement of Capabilities (Minimum Mandatory Requirements): Any interested supplier must demonstrate by way of a statement of capabilities that its system meets the following requirements: I. Test Method and Configuration Ia. The Analyzer must quantitatively measure certain species present in the heavy-duty internal combustion engine exhaust described under “II. Test Species, Ranges, and Resolutions” below using Fourier Transform Infrared Spectroscopy. Ib. The Analyzer must be able to analyze spectra in the 600-4300 cm-1 range at a resolution of 0.5 cm-1 or better. Ic. The analyzer must include a humidity-protected beam splitter. Id. The Analyzer must record all data at the rate of 1 Hz or higher. Ie. The Analyzer must have the capability to measure at least 40 gases simultaneously. If. The Analyzer must have the capability of storing quantitative and spectral data simultaneously and continuously. 1g. The Analyzer must have the ability to compensate for sample pressure fluctuations automatically. Ih. The Analyzer must have means for data to be read by or transmitted to other data acquisition systems either through one or more of the following interfaces – web-based, analog signal, digital signal, TCP/IP protocol, or AK protocol. 1i. The Analyzer must be able to operate within an ambient temperature range of 15 to 40 °C. 1j. The Analyzer must be compatible with standard 19-inch rack mount. 1k. The Analyzer must have an accuracy within 2% of the full-scale reading. 1l. The Analyzer must use a gas cell made of 316 stainless steels. 1m. The Analyzer must use a gas cell with a path length of at least 10 metres. 1n. The Analyzer must allow the user to set the gas cell temperature to 191 °C. 1o. The Analyzer must have an infrared source which can be replaced by the user at the end of its service life. II. Test Species, Ranges, and Resolutions IIa. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Methane (CH4) Range: 0-2000 ppm Resolution: =1 ppm IIb. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Formaldehyde (HCHO) Range: 0-50 ppm Resolution: =1 ppm IIc. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Acetylene (C2H2) Range: 0-1000 ppm Resolution: =1 ppm IId. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Ethylene (C2H4) Range: 0-500 ppm Resolution: =1 ppm IIe. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Ethane (C2H6) Range: 0-500 ppm Resolution: =1 ppm IIf. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Dimethyl ether (C2H6O) Range: 0-0.75% Resolution: =0.5% of full scale IIg. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Propane (C3H8) Range: 0-100 and 0-1000 ppm Resolution: =1% of full scale IIh. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Propylene (C3H6) Range: 0-1000 ppm Resolution: =1 ppm IIi. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Nitric oxide (NO) Range: 0-1000 and 0-5000 ppm Resolution: =0.5% of full scale IIj. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Nitrogen dioxide (NO2) Range: 0-1000 and 0-5000 ppm Resolution: =0.5% of full scale IIk. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Nitrous oxide (N2O) Range: 0-500 ppm Resolution: =1 ppm IIl. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Ammonia (NH3) Range: 0-1000 and 0-10000 ppm Resolution: =0.5% of full scale IIm. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Carbon monoxide (CO) Range: 0-1000 ppm, 0-5000 ppm, and 0-20% Resolution: =0.5% of full scale IIn. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Carbon dioxide (CO2) Range: 0-25% Resolution: =0.5% of full scale IIo. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Total hydrocarbon (THC) Range: 0-10 and 0-10000 ppm Resolution: =0.5% of full scale IIp. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Water (H2O) Range: 0-20% and 0-55% Resolution: =0.5% of full scale IIq. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Sulfur dioxide (SO2) Range: 0-1000 ppm Resolution: =1 ppm IIr. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Toluene (C7H8) Range: 0-300 ppm Resolution: =1 ppm IIs. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Methanol (CH3OH) Range: 0-400 ppm Resolution: =1 ppm IIt. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Ethanol (C2H5OH) Range: 0-275 ppm Resolution: =1 ppm IIu. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: 2-Propanol (C3H7OH) Range: 0-500 ppm Resolution: =1 ppm IIv. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Methyl amyl ketone (C7H14O) Range: 0-20 ppm Resolution: =1 ppm IIw. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Methyl ethyl ketone (C4H8O) Range: 0-400 ppm Resolution: =1 ppm IIx. The Analyzer must measure the exhaust gas component with the range and resolution described as follows – Component: Methyl isobutyl ketone (C6H12O) Range: 0-100 ppm Resolution: =1 ppm III. Certification IIIa. At the time of delivery, the Analyzer must include hard copy of calibration certificate(s) for species and ranges described in “2. Test Species, Ranges, and Resolutions” IV. Computer and software for test operation, data acquisition and analysis IVa. The Analyzer must include an internal or external computer with Windows 10 or 11 operating system, ethernet connection, USB port, and a primary high-resolution display of at least 10-inch size. The computer must also be able to connect to an external monitor and be able to connect to the internet using wi-fi network. This computer must be loaded with perpetual license software for operating the Analyzer, data acquisition, data analysis, and post-processing. The contractor must provide backup for the software. IVb. The Analyzer must allow NRC to add gas calibrations for measuring other species and ranges in addition to those listed in “2. Test Species, Ranges, and Resolutions” through electronic means such as the software, provided the calibrations for such species and ranges can be quoted by the Contractor. V. Zero Air Generation System Va. The Analyzer must include a zero air generation system which can be used for purging of or conducting background checks on the Analyzer in place of gaseous nitrogen. NRC will provide compressed air supply. VI. Heated Sample Line – 191 °C (25 feet long) VIa. The Analyzer must be provided with one 25 feet (7.62 metres) long heated sample line (=191°C) with controller and all necessary accessories to connect to exhaust pipe. VII. Heated filter VIIIa. The Analyzer must be provided with a heated sample filter and controller which can be installed immediately downstream of the sampling probe. VIII. Sampling system VIIIa. The Analyzer must be provided with a suitable sampling system which can extract sample gas through the heated sample line while maintaining and measuring appropriate flow rate of the sample gas, and maintaining temperature of the sample gas to at least 191°C before sending this gas into the Analyzer for analysis. This sampling system must remove particulate matter from the sample gas, and must provide means to switch Analyzer input flow between calibration and sample gas. IX. Power supplies and cables IXa. The Analyzer and its accessories must include all power supplies, cables, and adapters and must be compatible to 120 VAC 60 Hz used in USA/Canada. X. Non-standard valves and regulators Xa. The Analyzer must be provided with any non-standard valves and/or regulators required for assembly and operation of items I, V, VI, VIII, and VIII. 4. Applicability of the trade agreement(s) to the procurement o Canadian Free Trade Agreement (CFTA) o Canada-Chile Free Trade Agreement (CCFTA) o Canada-Colombia Free Trade Agreement o Canada-Honduras Free Trade Agreement o Canada-Korea Free Trade Agreement o Canada-Panama Free Trade Agreement o Canada-Peru Free Trade Agreement (CPFTA) 5. Set-aside under the Procurement Strategy for Aboriginal Business Not applicable 6. Comprehensive Land Claims Agreement(s) Not applicable 7. Justification for the Pre-Identified Supplier: The pre-identified supplier is the sole provider that meets all or the minimum essential requirements as described in Section 3. The supplier system is compatible with current gas analysis and data acquisition systems at the National Research Council, Energy, Mining and Environment Research Centre. 8. Government Contracts Regulations Exception(s) The following exception(s) to the Government Contracts Regulations is (are) invoked for this procurement under subsection (d) - "only one person is capable of performing the work". 9. Exclusions and/or Limited Tendering Reasons The following exclusion(s) and/or limited tendering reasons are invoked under the: a. Canadian Free Trade Agreement (CFTA) – Article 513 (1) (b) (iii): due to an absence of competition for technical reasons; b. Canada-Chile Free Trade Agreement (CCFTA) – Article Kbis-16 (2) (c): necessary to protect intellectual property; c. Canada-Colombia Free Trade Agreement – Article 1409 (1) (b) (iii): due to an absence of competition for technical reasons; d. Canada-Honduras Free Trade Agreement – Article 17.11 (2) (b) (iii): due to an absence of competition for technical reasons; e. Canada-Korea Free Trade Agreement – referencing the WTO Protocol Amending the GPA, Article XIII (1) (b) (iii): due to an absence of competition for technical reasons; f. Canada-Panama Free Trade Agreement – Article 16.10 (1) (b) (iii): because of the absence of competition for technical reasons; g. Canada-Peru Free Trade Agreement (CPFTA) –Article 1409 (1) (b) (iii): due to an absence of competition for technical reasons; 10. Ownership of Intellectual Property: Not Applicable 11. Period of the proposed contract or delivery date: NRC is expecting the equipment to be delivered within the month of March 2024, based on the date of the contract. Delivery time frame is expected to take 6 months. 12. Name and address of the pre-identified supplier: California Analytical Instruments, Inc. 1312 West Grove Avenue, Orange, California 92865 USA 13. Suppliers' right to submit a statement of capabilities: Suppliers who consider themselves fully qualified and available to provide the goods, services or construction services described in the ACAN may submit a statement of capabilities in writing, within 15 days, to the contact person identified in this notice on or before the closing date of this notice. The statement of capabilities must clearly demonstrate how the supplier meets each of the advertised requirements in Section 3. 14. Closing date for a submission of a statement of capabilities: The closing date and time for accepting statements of capabilities is September 28, 2023 at 2:00PM EDT. 15. Inquiries and statements of capabilities are to be directed to: E-mail: Name: Kacendra Dion Title: Senior Contracting Officer Organization: National Research Council Canada Telephone: +1 (555) 000-0000 E-mail address: contact@example.gov

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS