Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity was posted on February 12, 2009. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Gas Detector: instrument must detect ortho-perflourodicyclohexane (oPDCH)

Closed
143301Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Agency

N/A

NAICS

335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing

Place of Performance

Brookhaven National Laboratory, UPTON, NY, 11973, USA

Set-Aside

NONE

Documents

1

City of Thousand Oaks - UCaaS and CCaaS with Teams Integration RFP/Q

PDF, High priority: read this firstrfp
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Jeanmarie Volkmanncontract specialist

Full Description

Show more
PLEASE SEE ATTACHED PDF FILES CONTAINING PRESOLICITATION NO. 143301 PLEASE DOWNLOAD THE FILES FROM THIS WEBSITE. ALL QUESTIONS, WHETHER TECHNICAL OR CONTRACTUAL, MUST BE SENT ELECTRONICALLY TO JEANMARIE VOLKMANN, contact@example.gov. IF YOU WILL BE RESPONDING TO THIS SOLICITATION, YOU MUST SUBMIT AN EMAIL TO contact@example.gov ACKNOWLEDGING YOUR PARTICIPATION IN THIS PRESOLICITATION. IF ANY QUESTIONS SHOULD ARISE, YOU WILL BE NOTIFIED ELECTRONICALLY. The instrument must detect ortho-perflourodicyclohexane (oPDCH) in soil gas (humid air with up to 90% methane) using cavity enhanced laser absorption spectroscopy that accurately and rapidly measures the concentrations of oPDCH in real time. It must be based on a commercially available platform, simple to operate, portable (less than - cubic meter, 24VDC or household current and less than 75 lbs), and short response time capable of directly measuring absorption spectra of oPDCH in ambient air in a measurement time of less than 30 seconds with a minimum sensitivity of <10 ppbv and a preferred sensitivity of at least 1 ppbv. The platform must contain an external cavity Infrared laser. Manufacturer must provide a calibration curve, software specific for oPDCH and an operations manual. Detection limits must be demonstrated at BNL before delivery/acceptance of the final turn key system. Offerors must provide documentation of no less than three (3) years of proven field deployment of at least 25 units per year.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS