Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Health And Human Services was posted on July 21, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

GE VOLUSON ULTRASOUND MACHINE

Awarded
246-21-Q-0104Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
Hearing Aid Fitting and Verification for Shiprock Service Unit (IEE or ISBEE Set Aside)
Solicitation # SS-SRSU-27-0003
The Indian Health Service Shiprock Service Unit is conducting market research through a sources-sought notice to identify capable Indian-owned economic enterprises, both large and small, to provide hearing aid fitting and verification services. The primary objective is to reduce hearing aid rejection and costly remakes while ensuring patients receive optimal benefit from their devices. The requirement includes the provision of equipment with advanced technical specifications, such as dual ear capability, a frequency range of 200 to 16,000 Hz, and a comprehensive test suite including speechmap counseling and pediatric probe tube placement. Additionally, the selected vendor must provide installation and training for the Audiology Department. This opportunity is categorized under NAICS code 334510 for electronic hearing aid manufacturing. In accordance with the Buy Indian Act, the government will prioritize responses from Indian-owned economic enterprises before considering other small business set-aside programs. Interested parties must be registered in the System for Award Management and submit a company profile, a capability statement, and a completed IHS IEE Representation Form by November 03, 2026. This notice is for market research purposes only and does not constitute a formal solicitation.
Navajo Area Indian Health Svc

POSTED

2 days ago

DEADLINE

in 5 days
NAICS: 334510
New
Federal
6515--ForeSite SS Tablet w/Pressure Mapping Sensor System
Solicitation # 36C24827Q0082
The Department of Veterans Affairs, through Network Contracting Office 8, is conducting market research via a Sources Sought Notice to identify authorized sources for the ForeSite SS Tablet Pressure Mapping System manufactured by ForeSite Medical. This effort is for acquisition planning purposes and is not a formal solicitation. The required system is intended for clinical pressure assessment and treatment and must include the tablet platform, pressure-mapping sensors, sensor packs, chargers, software licenses, cables, and all necessary accessories. Key functional requirements include real-time pressure analysis and visualization, patient data storage and reporting, wireless and wired connectivity, and portable battery-powered operation. All equipment must be new and include the manufacturer's standard warranty. Interested vendors must submit electronic responses in PDF or Word format by October 30, 2026. Submissions must include the company name, address, Unique Entity Identifier, point of contact, and business size or socioeconomic status, such as SDVOSB, VOSB, Small Business, or Large Business. Additionally, respondents must provide documentation proving they are authorized to distribute or resell the ForeSite system, an estimated delivery lead time, and confirmation regarding the new condition and warranty of the product. The place of performance is located in Tampa, Florida, under NAICS code 334510.
248-NETWORK Contract Office 8 (36C248)

POSTED

3 days ago

DEADLINE

in about 5 hours
NAICS: 334510
New
Federal
Ocular Scanner
Solicitation # W91CRB-26-AWSP-Scanner-Ultrasonic-Ocular-RPP
The Portfolio Acquisition Executive Maneuver Ground Project Manager Maneuver Medical Systems is soliciting prototype proposals for a Scanner Ultrasonic Ocular device under Other Transaction Authority pursuant to 10 U.S.C. 4022. The objective is to award two prototype agreements for the delivery and demonstration of FDA-approved commercial solutions that provide anatomical visualization and diagnostic imaging of the eye, specifically for the anterior and posterior segments. Awardees are required to deliver four prototype units within 45 to 60 days of award for operational and environmental testing conducted in accordance with MIL-STD-810H. The estimated period of performance is twelve months, with awards expected around the first quarter of fiscal year 2027. The procurement utilizes a comparative best-value methodology, prioritizing technical approach, performance compliance, reliability, schedule realism, and past performance over cost. Key requirements include Trade Agreements Act compliance, MIL-STD-130N marking for hardware, and the provision of ruggedized transport cases. Deliverables encompass the hardware units, comprehensive user and maintenance manuals, cybersecurity documentation, and on-site operator training. Proposals must be submitted as four separate PDF volumes via DoD SAFE or secure email by November 12, 2026. This action is a direct Other Transaction Agreement and is not subject to the Federal Acquisition Regulation or Defense Federal Acquisition Regulation Supplement.
W6QK Acc-Apg

POSTED

3 days ago

DEADLINE

in 14 days

General Info

Contract Value

$131,969

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

Claremore, OK, 74017, USA

Set-Aside

BICiv

Award Issued Date

Documents

1

RFQ+246-21-Q-0104.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Health And Human Services → Ok City Area Indian Health Svc
Contacts1 person available
OfficeOKLAHOMA CITY, OK, 73114, USA
Office AddressOKLAHOMA CITY, OK, 73114, USA

Full Description

Show more
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested in response to this notice and a written solicitation will NOT be issued. This solicitation is being issued as a Request for Quote (RFQ). Submit only written quotes for Carestream revolution. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2021-05. This solicitation is a Buy Indian Set Aside. The associated NAICS code is 334510 with a size standard of 1,250 employees. This RFQ contains two (2) Line Item: CLIN DESCRIPTION QTY UNIT Unit Price TOTAL 0001 GE VOLUSON ULTRASOUND MACHINE 1 EA 0002 Trade in of AcusonSequoia and LOGIQ 5 1 LOT PERIOD OF PERFORMANCE: 45 Days ARO Vendor Requirements: Submit Quotes no later than: 08/04/2021 @ 10:00 am CST to the Following Point of Contact: Sean Long Email: contact@example.gov Questions and Answers: N/A Evaluation: FAR 52.212-2 Evaluation -- Commercial Items (completed as follows): (a) The Government will award a firm fixed price contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: Lowest Price Technically Acceptable To be considered technically acceptable you must meet or exceed the specifications listed in statement of work and SHALL BE COMPATIBILE WITH CARESTREAM PACS SYSTEM. VENDORS SUBMITTING OR EQUAL ITEMS MUST SUMBMIT DESCRIPTITVE LITERATURE SHOWING HOW THEIR PRODUCT MEETS OR EXCEEDS THE REQUIREMENTS BEING SOLICITED. This solicitation will result in a firm fixed price purchase order pursuant to the terms and conditions below. Terms and conditions other than those stated will not be accepted. The above pricing is all inclusive. PROVISIONS: The following FAR provisions apply to this solicitation: FAR 52.212-1, Instructions to Offeror- Commercial Items; FAR 52.212-3, Offeror Representations and Certifications- Commercial Items (the offeror should include a completed copy of this provision with their quote). CLAUSES: The following FAR clauses apply to this solicitation: FAR 52.212-4, Contract Terms and Conditions-Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required to Implement Statues or Executive Orders-Commercial Items (to include the following clauses sited): FAR 52.203-6 Restrictions on Subcontractor Sales to the Government; 52.203-13, Contractor Code of Business Ethics and Conduct; FAR 52.204-10, Reporting Executive Compensation and First-Tier Subcontract Awards; FAR 52.209-6, Protecting the Government's Interest When Subcontracting with Contractors Debarred, Suspended, or Proposed for Debarment; FAR 52.217-8, Option to Extend Services, FAR 52.217-9, Option to Extend the Term of the Contract, FAR 52.219-8; FAR 52.219-13,; FAR 52.219-28,; FAR 52.222-3, Convict Labor; FAR 52.222-19, Child Labor-Cooperation with Authorities and Remedies; 52.222-21, Prohibition of Segregated Facilities; FAR 52.222-26, Equal Opportunity; FAR 52.222-35 Equal Opportunity for Veterans; FAR 52.222-36, Equal Opportunity for Workers with Disabilities; FAR 52.222-37 Employment Reports on Veterans; FAR 52.222-40, Notification of Employee Rights Under the National Labor Relations Act; FAR 52.222-50, Combating Trafficking in Persons; FAR 52.223-18, Encouraging Contractor Policies to Ban text Messaging While Driving; FAR 52.225-1, Buy American Act--Supplies; FAR 52.225-13, Restriction on Certain Foreign Purchases; FAR 52.232-33, Payment by Electronic Funds Transfer- System for Award Management; FAR 52.222-41, Service Contract Act of 1965; FAR 52.222-43 Fair Labor Standards Act and Service Contract Act - Price Adjustment. The above Provisions and Clauses may be obtained via internet at http://farsite.hill.af.mil. Miscellaneous: NO FAX QUOTATIONS ELECTRONIC SUBMISSIONS - SUBMISSION VIA EMAIL IS THE ONLY ACCEPTABLE ELECTRONIC SUBMISSION. (contact@example.gov) Mail quotations to Claremore Indian Hospital, Attn: Sean Long, 101 S Moore Ave, Claremore, OK 74017. NO late quotes will be accepted. All contractors must be registered in the System for Award Management database located at https://www.sam.gov/sam/ prior to any contract award. Please submit the following information with each quote: Vendor Name, Cage Code, DUNS number, Tax Identification Number, Prompt Payment Terms, Delivery Time, GSA Contract Number (if applicable), Date quote expires, warranty, total price for each line item, total quote price, and technical documentation in sufficient detail to determine technical acceptability. Failure to provide sufficient technical detail may result in rejection of your quote. For additional information, please contact the Contracting Officer, Sean Long contact@example.gov or +1 (555) 000-0000. SPECIFICATIONS GE Voluson E10 BT21 1. General Requirements 1.1 Description of Requirements Claremore Indian Hospital (CIH) Radiology Department seeks to procure a GE Voluson E10 General Ultrasound machine to perform Obstetrics, Gynecology, Abdomen, Cardiac, Small Parts and Vascular exams. The GE Voluson E10 ultrasound machine has interchangeable transducers that can be used with our Current GE Vivid E9 Ultrasound machine. This will enhance patient work-flow and allow for surplus probes in the event of malfunction. 1.2 Delivery Location Claremore Indian Hospital Radiology 101 S. Moore Claremore, OK 74017 1.3 Specifications a. Voluson E10 BT21 - High Resolution 22 OLED Monitor - Radiance System Architecture - Radiantflow - SlowflowHD and Slowflow3D - HDlive* Technology - Advanced VCI with OmniView - Uterine Trace - Advanced STIC & eSTIC - Advanced Fetal Echo - fetalHQ - Scan Assistant - Automation Technology with SonoCNS, SonoBiometry, SonoNT, SonoIT - XDclear Probes - Volume Matrix Technology - High Frequency Transvaginal Imaging - Electronic 4D Technology - 3D Printing Capabilities User Interface Operator Keyborad Floating Keyboard: - Rotation: adjustable +/- 38 from center - Height adjustable + 195 mm (7.9) Full-sized, backlit alphanumeric keyboard Ergonomic hard key layout Interactive backlighting Integrated recording keys for remote control of up to 6 peripherals or DICOM devices, one dedicated DVD recording key. Touch Screen 12.1 high resolution color LCD screen Multi touch interactive dynamic software menu Brightness adjustable xTouch capable, supporting Volume rotation, MagiCut, HDlive light source manipulation and OmniView Capable to display 2D/3D/4D Ultrasound Images in real time Monitor 22 OLED Display Resolution Full HD 1920 x 1080 pixel Display brightness up to 300 cd/m (OLED: 205 cd/m) Tilt/Rotate Adjustable Monitor Tilt angle: min. +30/-75 Horizontal rotate angle: +/- 90 Digital brightness and contrast adjustment. Five default settings available: Extra Dark, Dark-, Semi Dark-, Light-, Extra Light Room, each for higher and lower color temperature System Overview Exam Types Abdominal Obstetrical and Fetal Echo Gynecological Small Parts and Breast Vascular Pediatrics Transrectal Cardiology Cephalic Musculoskeletal (MSK) Operating Modes Brightness Mode (B-Mode) (2D) Bi-Plane Mode, including steering of orthogonal plane Motion Mode - M-Mode (conventional M-Mode) Anatomical M-Mode (AMM) Pulsed Wave Doppler (PW) with automatic HPRF Continuous Wave Doppler imaging (CW) Color Flow Doppler mode (CFM) Power Doppler Mode (PD) High Definition Power Doppler (HD-Flow*) SlowflowHD & Slowflow3D Tissue Doppler Mode (TD) and PW-Tissue Doppler Mode B-Flow* (BF) Compression Elastography Combination modes: M/CFM, M/HD-Flow, M/TD, PW/CFM, PW/HD-Flow, PW/PD, PW/TD Extended View (XTD View) Volume Mode (3D/4D): 3D Static 4D Real Time VCI-A VCI-OmniView Spatio-Temporal Image Correlation (STIC) & eSTIC 4D Biopsy Privacy and Security Functionality Hard disc AES Encryption with 256-bit length Whitelisting Encrypted DICOM Communication Capability (TLS) Encryption and Data Anonymization Export Capability All ports, services and shared resources that are not required for the intended use are disabled Operating System Access disabled Deactivation of USB ports possible System Standard Features Innovative user interface with high resolution 12.1 LCD touch panel B-Mode M-Mode PW-Doppler CFM (Color Flow Doppler Mode) Automatic Optimization (B-Mode, PW Doppler) Auto TGC AutoScale (PW Doppler and Color Doppler PRF) Coded Harmonic Imaging with Pulse Inversion Technology, operating on multiple frequencies, with user selectable on/off button Coded Excitation (CE) HD-Flow & Power Doppler Mode Radiantflow & SlowflowHD & Slowflow3D B-Flow Tissue Doppler and PW-Tissue Doppler XTD SRI II (Speckle Reduction Imaging) HDlive Silhouette, HDlive Studio HDlive Flow, HDlive Flow Silhouette CrossXBeamCRI* (Compound Resolution Imaging) SonoBiometry (HC, BPD, AC, FL, HL, SonoNT & SonoIT) SonoCNS SonoRenderlive Scan Assistant: Includes measurements, annotations and fetal anatomy and gynecology worksheet entries. Performs predefined mode changes, preset selection and screen layout changes. Supports display of user selected reference images. Standardize image sequence upon DICOM transfer DICOM 3.0 Connectivity Focus and Frequency Composite (FFC) HD Zoom & Pan Zoom Steering Virtual Convex (Trapezoid Image, also with CrossXBeam (CRI) Wide Sector Beta-View Histogram Analysis with up to 3 user adjustable ROIs with comparative analysis on complex curves Patient information database Image Archive on hard drive 3D/4D data compression (lossy/lossless) Inversion Mode Real-time automatic Doppler calculations Multigestational Calculations Integrated uplink for Cloud-based data storage (TricefyTM) GYN IOTA LR2, Simple Rules and ADNEX Model GYN IETA Protocol & Report GYN IDEA Protocol & Scan Assistant Guideline Advanced 4D V-SRI Steerable CW Mode Anatomical M-Mode (AMM) with up to 2 cursers Advanced Security Features Premium Security Features: Standard on Government system configuration Voluson Remote Updates Advanced STIC: Basic STIC STIC M-Mode STIC-Flow - SonoVCADheart Cine Features Prospective or Retrospective Cine Mode Dual/Quad image CINE Display CINE Gauge and CINE image number display CINE Review Loop Selectable CINE Sequence for CINE Review (by Start Frame and End Frame) Side Change in dual CINE Mode Measurements /Calculations & Annotations on CINE Length: 2D: 512MB: up to 10 min (depending on B-image size and FPS); typical: about 3 min/4000 images (with curved array: 15cm depth, angle 81, 22 FPS) M-Mode: 32MB: up to 1 min motion time (depending on sweep and depth) PW/CW-Mode: 32MB: up to 1 min motion time (depending on sweep speed) Cine operation: Manual: image by image, Auto run: speed: 25 to 200% of real-time rate play repeat mode: forward-forward, forward-backward-forward b. 9L-D Linear Array Probe Wideband Linear Array Probe. Applications vary depending on the ultrasound system and may include Vascular, Small Parts, Pediatric, and Abdominal. Datasheets for specific ultrasound systems contain additional details including specific applications, biopsy availability, and additional probe technical specifications. c. ML6-15-D Matrix Linear Array Probe Wideband Matrix Linear Array Probe. Applications vary depending on the ultrasound system and may include Small Parts, Vascular, Pediatrics, Neonatal, Breast, Thyroid, and Scrotal. Datasheets for specific ultrasound systems contain additional details including specific applications, biopsy availability, and additional probe technical specifications. d. C1-6-D XDclear* Convex Array Probe Convex Array probe with GE's highest performing XDclear* transducer technology, an innovative combination of advanced materials and acoustic design providing ultra-wide bandwidth and superb image quality. Applications vary depending on the ultrasound system and may include Abdominal, OB/GYN, Urology, and Vascular. Datasheets for specific ultrasound systems contain additional details including specific applications, biopsy availability, and additional probe technical specifications. *Trademark of General Electric Company e. RAB6-D Ultralight Real Time 4D Convex Array Probe Ultralight, Wideband Real Time 4D Convex Array Probe. Applications vary depending on the ultrasound system and may include Abdominal, OB/GYN, and Pediatric. Datasheets for specific ultrasound systems contain additional details including specific applications, biopsy availability, and additional probe technical specifications. f. RIC5-9-D Real Time 4D Microconvex Probe Wideband Real Time 4D Microconvex Array Intercavity Probe. Applications vary depending on the ultrasound system and may include OB/GYN, and Urology . Datasheets for specific ultrasound systems contain additional details including specific applications, biopsy availability, and additional probe technical specifications. g. Advanced Volume Contrast Imaging (VCI) with OmniView VCI is a volume acquisition technique that helps provide contrast enhancement and speckle suppression in the 2D ultrasound image. Specifically, VCI utilizes GE's Real Time 4D transducers to automatically scan multiple adjacent slices resulting in a thin surface rendered image of a solid organ. Advanced VCI with OmniView helps improve the contrast resolution and visualization of the rendered anatomy in an image plane, even with as irregularly shaped structure. h. ECG Digital Module i. B/W Printer UP-D898DC USA Kit B/W Digital Printer with Paper j. Training Three days of on-site applications training. Training must be completed within six (6) months after Product delivery, otherwise GE Healthcare's obligation to provide the training will expire without refund. Customer workflow permitting and abiding by SDMS criteria, sonographer install CE's may be provided during install training. Included, as part of purchase, are 3 memberships to Voluson Club. Registration required for Voluson Club membership. 1.4 Contractor Furnished Property, Facilities and Services a. The Indian Health Service requires the contractor to provide all tools, parts and labor for this contract. b. Trade-in required for AcusonSequoia and LOGIQ 5 to include the Voluson EDGE Discount of $10,000. c. Installation, set-up and training of GE Voluson E10 unit will be completed by GE certified service engineer. Contractor will ensure the unit's communication and compatibility with Carestream PACS system. d. One year warranty and service coverage, to include remote service and support, will be included with purchase of GE Voluson E10. 1.5 Technical Points of Contact Stephanie McAlvain Radiology Supervisor Phone +1 (555) 000-0000 E-mail contact@example.gov 1.6 Invoicing Invoices shall include the following information: a. Contractor Name, Address and Phone Number b. Date of Invoice c. Unique Invoice Number d. Basic Contract Number as shown on the OF347 award document e. Modification Number (if applicable) f. Title of Invoice g. Description of Work relating to Invoice h. Invoice Amount An original invoice shall be submitted upon completion of services to: Oklahoma City Area Indian Health Service Office of Financial Management Attn: Denise Karr 701 Market Drive Oklahoma City, OK 73114 With a courtesy copy to: Claremore Indian Hospital Attn: Stephanie McAlvain 101 S. Moore Claremore, OK 74017 Phone +1 (555) 000-0000 Email: contact@example.gov 1.7 Contact with Indian Children Individuals providing services which involve regular contact with, or control over, Indian children, are subject to a character investigation. IHS personnel offices will conduct these investigations following award of non-personal services contract unless in the judgment of the Contracting Officer, in consultation with the personnel Officer, investigation may be waived based on prior investigation on file. Until the Contracting Officer has been notified of the result of the investigation, such individuals shall not have unsupervised contact with Indian children.

More opportunities from Department Of Health And Human Services → Ok City Area Indian Health Svc

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS