This Government Contract opportunity from Department Of Veterans Affairs was posted on March 15, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H--Electrical Testing

Awarded
VA24116Q0202Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Department of Veterans Affairs has issued a contract for comprehensive electrical testing and maintenance of the Electrical Power Distribution System. The contractor is responsible for the inspection, testing, and function testing of various equipment, including switchgear, transformers, circuit breakers, protective relays, grounding systems, and emergency generators. Key technical requirements include performing infra-red thermographic surveys to detect hot spots and ensuring all work complies with NETA Maintenance Testing Specifications and VHA Directives. Due to the clinical nature of the facility, approximately 75 percent of the work must be performed during off-hours and weekends, with all activities coordinated two weeks in advance with Facilities Management. A critical component of the scope is the participation in a four-hour Essential Electrical System power outage test to verify emergency power transfers and system stability. The contractor must provide a detailed progress schedule, report critical deficiencies immediately, and cover all costs associated with local utility services during the outage test.

General Info

Contract Value

$83,100

NAICS

541380 - Testing Laboratories and Services

Place of Performance

ME

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

2 updates
PhaseAwarded
Posted

Presolicitation

Notice updated

The notice description changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
ContactsNo contacts available
OfficeTOGUS, ME, 04330, USA
Office AddressTOGUS, ME, 04330, USA
ContactsNo contact information available

Full Description

Show more
Summary of Work: A. The Contractor shall provide a proposed schedule with their bid proposal. The schedule shall be in the form of a progress chart of suitable scale to indicate the work scheduled for completion by any given date during the work period. The proposed schedule shall be reviewed by the VAMC Facilities Management; any requirements for adjusting the schedule (e.g. to minimize disruption to the VAMC) shall be incorporated by the Contractor. B. Contractors shall report deficiencies that are deemed critical or catastrophic immediately to the Contracting Officer and Chief of Facilities Management for immediate actions. C. Work items, definitions, and references shall comply with the latest edition of the NETA - Maintenance Testing Specifications (MTS) and with the VHA Directive, Electrical Power Distribution System. Below is a list of electrical equipment that shall be maintained and tested: 1. Switchgear and Switchboard Assemblies. 2. Transformers, Dry Type, Air-Cooled, Low-voltage, Small. 3. Transformers, Liquid-Filled. 4. Switches, Air, Low-Voltage. 5. Switches, Air, Medium-Voltage, Metal-Enclosed. 6. Circuit Breakers, Air, Insulated-Case/ Molded-Case. 7. Circuit Breakers, Air, Medium-Voltage. 8. Circuit Breakers, Vacuum, Medium-Voltage. 9. Protective Relays, Mechanical, and Solid State. 10. Protective Relays, Microprocessor Based. 11. Grounding Systems. 12. Ground-fault Protection Systems. 13. Emergency Systems, Engine Generators. 14. Emergency Systems, Automatic Transfer Switches. D. Attachments. Government Furnished. 1. Inventory of Electrical Power Distribution System equipment to be maintained, inspected, and tested under this Scope of Work. 2. One-line and other informational drawings of the Electrical Power Distribution System. These drawings are not certified as-built drawings. 3. Arc-flash hazard analysis and available protective device setting information. E. Infra-Red Scanning/Thermographic Survey shall be performed on electrical equipment. : 1. Use an infra-red scanning camera to detect hot spots in the Electrical Power Distribution System. Objective of this work is to detect any loose, broken, or corroded connections in the system. Problem connections shall be replaced with new connectors, and/or tightened with torque wrench to meet the equipment manufacturers' specifications. 2. Note that since this work item must be done while the Electrical Power Distribution System is energized, appropriate safety precautions must be taken before, during and after scanning the system. F. System Function Tests. Provide function test for all equipment listed in this Scope of Work. G. Test Conditions. 1. Tests will be conducted on a scheduled basis with the Facilities Management staff on site. 2. Testing will require off-hours and weekend work in some locations due to the clinical nature of the areas and the requirement to maintain functionality at all times. 3. Testing will be coordinated and planned with the involvement of on-site facilities management staff. Approval must be received on the plan prior to the contractor performing work. All work to be coordinated well in advance, at least 2 weeks, to provide adequate time for coordination. A schedule must be provided by the contractor after award is received. 4. The contract work will require approximately 75% to be completed during off-hours and weekends between 9pm and 7am and weekends, excluding Federal Holidays. There may be areas that can be scheduled at times outside of this window upon approval. H. 4-Hour Power Outage Test The Contractor shall be present for and will participate in the VAMC 4- hour test of the Essential Electrical System (EES). This test shall fulfill the requirements of VHA Directive, Electrical Power Distribution System, NFPA 110 (e.g. Para. 8.4.9.) and The Joint Commission. This test will include opening of all utility service connections serving the VAMC for a minimum of 4-hours. During the test period, verify operation of all EES components including the transfer to emergency power and return to normal service. The Contractor shall include in their bid proposal all costs associated with the services of the local utility company for the duration of the test. The estimated duration of the Contractor's involvement is between 8 - 12 hours. The Contractor shall assist the VAMC staff with troubleshooting and correcting malfunctioning electrical equipment discovered during the test. Contractor shall make any required adjustments and/or re-calibrations to all equipment which has been otherwise maintained, inspected, and tested under this Scope of Work.

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

NAICS: 238990
New
Federal
Replacement-in-Kind Repair of Existing Perimeter Security Fence (Ameristar Impasse Trident) Brand Name or Equal
Solicitation # 36C24127Q0041
The Department of Veterans Affairs VA Boston Healthcare System is soliciting a contract for a localized replacement-in-kind repair of the perimeter security fence at the Brockton VA Campus in Massachusetts. The project focuses on restoring five affected fence bays and six associated post locations that were damaged by winter snow-removal activities. The objective is to return the damaged sections to their original alignment, configuration, appearance, structural stability, and security function. The benchmark product is the Ameristar Impasse Trident system, and while genuine components are preferred, equal alternatives may be proposed if they meet all salient characteristics, including the use of corrosion-resistant tamper-resistant hardware and the maintenance of a continuous security boundary. This procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238990. The period of performance is scheduled from December 1, 2026, to January 31, 2027. Award decisions will be based on the most advantageous offer, considering price, technical capability, and past performance, with a requirement for three relevant references. Proposals must be submitted in three separate PDF volumes (Technical, Past Performance, and Price) to the contract specialist by November 5, 2026. Final acceptance is contingent upon a satisfactory installation inspection, which may include a review by VA Police to ensure operational security.
All Other Specialty Trade Contractors

POSTED

1 day ago

DEADLINE

in 7 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS