This Sources Sought opportunity from Department Of Veterans Affairs was posted on August 2, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H312--TVHS Wet Chemical Fire Protection l Annual Inspections l Base +4 Option Years

Closed
36C24922Q0524Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 561210
New
Federal
Z1NE--RFQ Semi Annual Industrial Wastewater Discharge Testing Huntington VAMC Base Year Plus Four Option Years
Solicitation # 36C24527Q0033
Solicitation 36C24527Q0033 is a Request for Quote for a firm-fixed-price contract to provide semi-annual industrial wastewater discharge testing for the Hershel Woody Williams VA Medical Center in Huntington, West Virginia. The scope of work requires the contractor to collect an 8-hour composite sample and at least four grab samples at sanitary manhole No. 18, ensuring all sampling and analysis adhere to EPA procedures under Section 304 (g) of the Clean Water Act and 40 CFR Part 136. The contract is structured with a base year and four subsequent option years, extending through November 30, 2031. The laboratory must provide proof of certification by the state of West Virginia for wastewater testing. Award will be made to the responsible offeror whose proposal is most advantageous to the government, based on a comparative evaluation of technical approach, capability, experience, past performance, and price. Technical evaluations will focus on lab certification and qualified personnel, while past performance requires evidence from two to three similar projects completed within the last five years. Special requirements include the presence of an OSHA-compliant competent person on-site during performance and the submission of detailed subcontracting plans. Invoicing is handled electronically via the FSC e-Invoice system. The procurement is unrestricted but welcomes small businesses and service-disabled veteran-owned small businesses under NAICS code 561210.
245-NETWORK Contract Office 5 (36C245)

POSTED

about 16 hours ago

DEADLINE

in 28 days

AI Contract Overview

Show more

This contract, solicitation number 36C24922Q0524, outlines the requirements for semi-annual maintenance and annual inspections of wet chemical fire protection systems and portable fire extinguishers at the Nashville and Murfreesboro VA Medical Centers. The scope of work includes the maintenance of Safety First and Ansul R101 systems in various kitchens, as well as the inspection of approximately 800 portable fire extinguishers and specialized suppression systems, including a Kidde dry industrial system and an HFC-125 clean agent system. All services must be performed in accordance with NFPA 17a and NFPA 10 standards, with specific requirements for the replacement of fusible links and the hydrostatic testing of chemical containers. The contract structure consists of a base year running from October 1, 2022, to September 30, 2023, with four subsequent one-year option periods extending through September 30, 2027. Maintenance for wet chemical systems is scheduled for March and September, while portable extinguisher inspections occur in May. The contractor is responsible for providing all labor and must ensure personnel are manufacturer-certified. While the contract covers maintenance, it does not include the cost of replacement parts, which must be approved by the Contracting Officer prior to installation. All work must be coordinated through the Contracting Officer's Technical Representative and performed during standard business hours to minimize disruption to facility operations.

General Info

NAICS

561210 - Facilities Support Services

Place of Performance

Tennessee Valley Healthcare System Nashville VA Medical Center 1310 24th Avenue South, Nashville, TN 37212 Alvin C. York VA Med, 3400 Lebanon Pike, Murfreesboro, TN 37129, TN

Set-Aside

NONE

Documents

1

TVHS Wet Chemical Fire Protection Annual Maintenance & Inspections

DOCX, High priority: read this first6 pages · sow
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Notice updated

Notice details unchanged. Attachments may have changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 249-NETWORK Contract Office 9 (36C249)
Contacts1 person available
OfficeMURFREESBORO, TN, 37129, USA
Office AddressMURFREESBORO, TN, 37129, USA
Contacts
L. Kyle LoveContract Specialist

Full Description

Show more
VA TVHS Engineering Service SOW 06.22 1 STATEMENT OF WORK WET CHEMICAL FIRE PROTECTION SYSTEMS AND PORTABLE FIRE EXTINGUISHERS TVHS, Nashville and Murfreesboro Campuses 1. INTRODUCTION AND SCOPE OF WORK Provide all labor and material necessary to perform semi-annual maintenance on hood fire suppression systems listed below for the Tennessee Valley Healthcare System. All work shall be performed in accordance with NFPA 17a, (latest edition) on the maintenance of wet chemical fire protection systems. Work shall include replacement of all fusible links, semi-annually and annually as required by code. (Approximately 54 fusible links). Nashville VA Medical Center 1310 24th Avenue South Nashville, TN 37212 Safety First ARS Wet Chemical System: Main Kitchen Rm. #1D131 (one each) Canteen Kitchen- Rm. #1E114 (two each) Murfreesboro Alvin C. York VA Medical Center 3400 Lebanon Pike Murfreesboro, TN 37129 Ansul R101 Fire Suppression System: Main Kitchen Rm. 102, Bldg. 2 Patient Dining Room- Rm. 104. Bldg.2 Canteen Rm. 106, Bldg. 107 Canteen Kitchen - Rm. 106C, Bldg. 107 Scope of Work will include base + 4 option year provisions. Base Year: 10/01/2022 to 09/30/2023 Option 1: 10/01/2023 to 09/30/2024 Option 2: 10/01/2024 to 09/30/2025 Option 3: 10/01/2025 to 09/30/2026 Option 4: 10/01/2026 to 09/30/2027 c. Annual maintenance inspection of all portable fire extinguishers per NFPA 10 (approximately 800 units total) located at the Nashville and Murfreesboro VA Medical Centers. d. Semi-Annual Test and Inspection of the following suppression systems at the Nashville Campus: (1) KIDDE IND-21 DRY INDUSTRIAL SYSTEM (1 CYLINDER AND 2 NOZZLES) LOCATED IN THE NASHVILLE CAMPUS HAZMAT TRAILER (2) HFC-125 FE-25 CLEAN AGENT SYSTEM (CHEETAH FIRE PANEL, EIGHT (8) CEILING SMOKE DETECTORS, TWO (2) HOLD/ABORT BUTTONS, EIGHT (8) HORN/STROBES, ONE (1) PULL STATION, AND TWO (2) CYLINDERS [HFC-125 WT 393.00, GROSS WT 77.50]) LOCATED AT NASHVILLE CAMPUS HOSPITAL DATA ROOM 2. REQUIREMENTS WET CHEMICAL FIRE PROTECTION SYSTEMS: a. INSPECTION SCHEDULE: Semi-annual preventive maintenance inspections shall be performed during the months of MARCH AND SEPTEMBER. Work must be performed in such a manner as to minimize any disruption to the kitchens. b. All work shall be performed between the hours of 8:00 a.m. and 4:30 p.m., Monday through Friday, excluding federal holidays. All work shall be coordinated through the Contracting Officer s Technical Representative (Supervisory Safety Engineer). The contractor shall sign in/out at the Engineering Office of the campus being visited. All reports shall be forwarded to the COTR within five (5) workdays. All deficiencies shall be brought to the attention of the COTR immediately for corrective action. c. The vendor shall conduct all inspections in accordance with the manufacturer s listed installation/maintenance manual and NFPA 17a (current edition). Maintenance of the Wet Chemical Fire Extinguishing Systems shall be that the extinguishing systems meet all relevant fire codes and standards at all times during the terms of the agreement. Maintenance shall include, but not be limited to, the following items: (1) Inspections to see that the hazard has not changed. (2) An examination of all detectors, the expellant gas container(s), the agent container(s), releasing devices, piping, hose assemblies, nozzles, alarms, and all auxiliary equipment. Verification that the agent distribution piping is not obstructed. The following methods may be used for verifying that the piping is not obstructed. In the event the system is taken out of service to complete this verification the vendor must provide an alternative means of fire protection or assure that food production is not interrupted. In the event that the system is discharged, the vendor is responsible for recharging the system and returning it to its ready state. 1. Disassembly of all piping 2. Purging of piping with nitrogen or dry air 3. Conducting a full or partial discharge test 4. Other methods recommended by the manufacturer e. Where semi-annual maintenance of any wet chemical containers or system components reveal conditions such as, but not limited to, corrosion or pitting in excess of the manufacturer s limits, structural damage or fire damage, or repairs by soldering, welding, or brazing, the affected part(s) shall be replaced or hydrostatically tested in accordance with the recommendations of the manufacturer or the listing agency. The hydrostatic testing of wet chemical containers shall follow the applicable procedures as dictated in NFPA 17A, 1998, section 5-5. NOTE: The cylinder containing wet chemical must be removed from service every twelve years and the wet chemical removed and examined, and the cylinder hydrostatically tested. All wet chemical systems shall be tested, which shall include a check of the detection system, alarms, and releasing devices, including manual stations and other associated equipment. A discharge of the wet chemical normally is not part of this test. In the event that any chemical is discharged during a test procedure, the vendor must immediately replenish the chemical and return the system to a ready status. PARTS: Where the maintenance of the system(s) reveals defective parts that could cause impairment or failure of proper operation of the system(s), the affected parts shall be replaced or repaired by the contractor in accordance with the manufacturer s recommendations. This service contract does not include parts and, therefore a list of parts with costs, needed to repair the system or to meet fire regulations must be submitted to the appropriate Engineering Service office prior to installation. (1) Fusible links are to be furnished and replaced annually. (2) Fixed temperature-sensing elements of the fusible metal alloy type shall be replaced at every six-month inspection. They shall be destroyed when removed. The year of manufacturer and the date of installation of the fixed temperature-sensing element shall be marked on the system inspection tag. The tag shall be signed or initialed by the installer. h. COMPETENCY OF CONTRACT PERSONNEL: The inspector must be familiar with the wet chemical fire extinguisher systems in use at this facility and be authorized by the manufacturer to make inspections of the systems for code compliance. Proof of certification must be furnished to the VA Medical Center. 3. REQUIREMENTS PORTABLE FIRE EXTINGUISHERS: Fire extinguishers shall be inspected as required by NFPA 10 during the month of May at each campus. There are approximately 400 fire extinguishers at each campus (Nashville and Murfreesboro) consisting of CO-2 and water mist. The inspection label shall include the following information: a. Month and year the test was performed, indicated by perforation, such as is done by a hand punch. b. Name or initials of the person performing the test and the name of the agency performing the test. 4. REFERENCES: Standards of operation must meet factory tolerance specifications at all times. All work shall be performed in accordance with NFPA 17a, (latest edition) on the maintenance of wet chemical fire protection systems and NFPA 10 on fire extinguishers. 5. DELIVERY: a. Maintenance of the Wet Chemical Fire Extinguishing Systems shall be that the extinguishing systems meet all relevant fire codes and standards at all times during the terms of the agreement. Semi-annual preventive maintenance inspections shall be performed during the months of NOVEMBER and MAY. Work must be performed in such a manner as to minimize any disruption to the kitchens. b. Fire extinguishers shall be inspected in the month of May at both campuses. c. SERVICEMAN / REPAIRMAN: When the inspector or service representative is on station for a PM inspection, he will report to the Engineering office at the respective campus (Nashville in Room D73 or Alvin C. York in Building 15) to sign in/out and coordinate the work with the Safety Specialist. The COTR can be contacted at (615) 456-6396. (2) Emergency maintenance during other than normal duty hours must be coordinated with the Boiler Plant Operator, Nashville Campus, at Ph: (615-873-6895) or the chiller plant operator at the Alvin C. York VAMC, (615) 225-4554. 6. PROGRESS AND COMPLIANCE: a. After a PM inspection or an emergency maintenance call, the inspector shall leave a signed service ticket with Engineering Service. The maintenance report, with recommendations if any, shall be given to the COTR. The service ticket must be signed by an Engineering Service employee. Payments will be made in arrears after receipt of a signed service report and certified invoice. 7. NOTES AND OTHER INFORMATION: a. Any additional charge in excess of the service contract must have the prior approval of the Contracting Officer before costs are incurred. b. The are no known security issues with this Scope of Work. c. Contractors are responsible for finding legal parking. Contractors may stop temporarily to drop off tools and supplies only. d. Contractors are required to obtain a Temporary ID Badge from Engr Svc, Bldg 18 Murfreesboro or Room D73 Nashville, while on VA property if not escorted during the entire visit by an Engr Svc employee. Other important considerations: Cite any other information that is necessary for potential respondents to understand the nature of the potential requirement or proposed acquisition. Capability statement /information sought: Response to this announcement shall not exceed 10 pages and should include the following information: (1) A tailored capability statement indicating the firm s ability to provide a product and related services; (2) The respondents UEI/DUNS number, organization name, address, point of contact, and size and type of business (e.g., SDVOSB/VOSB, etc,) pursuant to the applicable NAICS code; (3) Information should be provided electronically in a Microsoft Word or Adobe PDF format. Please e-mail your response with the above information to loren.love@va.gov with the subject line "Sources Sought Notice # 36C24922Q0524 by 08:00 a.m. on 08/08/2022. Any questions should be emailed to loren.love@va.gov. Disclaimer and Important Notes. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization s qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality. No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).

More opportunities from Department Of Veterans Affairs → 249-NETWORK Contract Office 9 (36C249)

Same awarding agency

NAICS: 238220
New
Federal
TVHS AC VRF System Installation
Solicitation # 36C24927Q0016
Solicitation 36C24927Q0016 is a request for a single-award, firm-fixed-price purchase order from the Department of Veterans Affairs to provide HVAC services at the Tennessee Valley Healthcare System Nashville Campus. The project involves the removal of an existing condenser and three air handling units and the installation of a new Variable Refrigerant Flow (VRF) system for five office spaces near the boiler office. The scope includes system start-up, testing, commissioning, and balancing of airflow and temperature control. The period of performance is scheduled from November 1, 2026, through December 31, 2026, with specific work hours designated for Friday through Sunday between 1800 and 2400 hours. This requirement is 100% set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238220. Award decisions will be based on a Best Value comparative evaluation considering technical capability, past performance, and price. The contractor is required to adhere to industry standards, OSHA 29 CFR 1910, and NFPA 70E safety guidelines. Key deliverables include operational verification documentation, daily field inspection reports, and a final written report submitted within ten working days of completion. Invoices must be submitted electronically, and payments will be processed via Electronic Funds Transfer.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

4 days ago

DEADLINE

in 4 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS