Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on November 13, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H365--Radiation Physicist - PM&R | Physicist Services - Intent to Sole Source - A-Bear Consult, LLC

Closed
36C24425Q0102Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

541380 - Testing Laboratories and Services

Place of Performance

Altoona, PA, USA

Set-Aside

NONE

Documents

2

SOW - Physicist Services (James E. Van Zandt Medical Center)

DOCX, High priority: read this first5 pages · sow
High

36C24425Q0102 - Radiation Physicist Services - Intent to Sole Source

DOCX, Low priority2 pages · presolicitation
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

special-notice

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)
Contacts1 person available
OfficePITTSBURGH, PA, 15215, USA
Office AddressPITTSBURGH, PA, 15215, USA
Contacts
Adriane PerrettiContract Specialist

Full Description

Show more
NOTICE OF INTENT TO AWARD SOLE SOURCE: Department of Veterans Affairs (VA) Regional Procurement Office East (RPOE), Network Contracting Office 4 (NCO 4) intends to award a sole source contract pursuant to FAR 13.106-1(b) with A-Bear Consult, LLC., located at 408 Richard St, Crowley, TX 76036. Pursuant to 38 U.S.C. 8127(b), the Government intends to award the sole source procurement to SDVOSB firm, A-Bear, utilizing VAAR 819.7008. The VA Altoona Healthcare System requires physicist support for on-site evaluation for all radiology equipment, review radiation safety policies and procedures, review of film badge reports, review integrity of radiation shields, review procedure protocols for CT and MRI, and review the integrity of both image acquisition and radiology physician display monitors. Services shall be provided for the Department of Veterans Affairs James E. Van Zandt Medical Center. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES; however, any responsible firm that believes it can meet the requirements may give written notification and capability statements prior to the response due date and time. Vendors shall indicate if they are the direct supplier or service provider of the items and/or authorized reseller/distributor. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to perform the requirements and must include relevant corporate experience along with the applicable contract number, total contract dollar amount, contract period of performance, details of the relevant services and customer point of contact with corresponding telephone number and email address. Responses must include following information: Company Name SAM number Company's address Point of Contact information (title, phone number and email address) Business size. Response received will be evaluated; however, a determination by the Government not to compete the proposed procurement based on responses to this notice is solely within the discretion of the Government. Information provided will not be returned. Responses are due by Friday, 11/15/2024 at 3:00 PM (EST). No submissions will be accepted after this date and time. Responses shall be submitted via email to contact@example.gov. The NAICS code for this acquisition is 541380 and the standard size is $19.0M. Statement of Work - Physicist Services SERVICE Contractor shall provide physicist support for on-site evaluation for all radiology equipment, review radiation safety policies and procedures, review of film badge reports, review integrity of radiation shields, review procedure protocols for CT and MRI, and review the integrity of both image acquisition and radiology physician display monitors. Services shall be provided for the Department of Veterans Affairs James E. Van Zandt Medical Center. - All services shall be provided in accordance with the specifications, terms and conditions contained herein. Service locations are indicated in the table below: Location Number Location Name Location Address #1 James E. Van Zandt Veterans Affairs Medical Center 2907 Pleasant Valley Boulevard Altoona, PA 16602 #2 DuBois VA Outpatient Clinic 5690 Shaffer Road DuBois, PA 15801 #3 Johnstown VA Outpatient Clinic 598 Galleria Drive Johnstown, PA 15904 #4 State College VA Outpatient Clinic 2581 Clyde Avenue State College, PA 16801 GENERAL Contractor will review all film badge (dosimetry) records to assess if occupational exposure levels are below regulatory limits and make recommendations regarding ALARA (As Low As Reasonably Achievable) guidelines. Contractor will perform integrity check of all personnel lead shielding devices to include approximately fifty (50) lead aprons and ten (10) thyroid shields. Provide telephone consultation as needed. Attend at a minimum two (2) quarterly MR/Radiation Safety Committee meetings, by telephone, to review protocols and general radiology practices related to patient safety. DIAGNOSTIC RADIOLOGY Contractor will perform testing to conform with requirements of federal, state, and local regulations, and Joint Commission Standards for the following equipment. Eleven (11) X-ray tubes One (1) of which is in each of the three alternate locations #2-4 given in the table One (1) Dexa tube One (1) Intraoral Dental tube One (1) Panoramic Dental tube Every other year update the Patient Radiation Exposure Monitoring Program in accordance with guidelines established by the U.S. Department of Health and Human Services, Food and Drug Administration (FDA). Surveys should satisfy the current Joint Commission standard for monitoring doses from diagnostic radiology procedures. MAGNETIC RESONANCE IMAGING Contractor will provide an on-site performance evaluation of one (1) MRI unit. The following parameters should be included in the final report: Magnetic Field homogeneity Alignment Light Accuracy Geometric or Distance Accuracy High Contrast Resolution Low Contrast Resolution (or contrast to noise ratio) Slice Position Accuracy Slice Thickness Accuracy Radio Frequency coil checks (Uniformity & SNR for all coils used clinically) Artifact Evaluation Procedure/Protocol Review as it relates to a general medical physics evaluation and determines if protocols meet general practice guidelines Acquisition Display Monitor Performance COMPUTED TOMOGRAPHY Contractor will perform an on-site performance evaluation of one (1) CT Scanner, and measure radiation output for typical clinical scans. The following parameters should be included in the final report: Procedure/Protocol Review Phantom and Scanner Alignment (Alignment Light Accuracy) Radiation Beam Width Slice/Image Thickness Accuracy Slice Position Accuracy (when prescribed from a scout image) CT number accuracy at different kVp outputs CT Number Accuracy & Uniformity Low Contrast Performance Image Uniformity and Noise Geometric or Distance Accuracy Artifact Evaluation High Contrast Spatial Resolution Acquisition Monitor Display Performance Radiation dose (CTDIvol) for four commonly used CT protocols Table Travel Accuracy To ensure compliance with JC standards a qualified medical physicist (QMP) will be available to meet remotely with the CT protocol committee established by the facility. The meeting frequency and times will be established by the committee. The QMP will assist with the establishment of dose notification and dose alert values (CTDIvol and/or DLP) for diagnostic CT imaging protocols used at the facility. On an annual basis, the QMP will perform a review of diagnostic CT examinations performed at the facility. The review process will include an analysis and comparison of all incidents where the radiation dose index exceeded expected dose index ranges identified in the imaging protocols and comparison of the data to established external benchmarks. The physicist staff must include a fully qualified physicist and a fully qualified physicist who will serve as the backup. The physicist performing the evaluations will have board certification by one or more of the following (if not board certified, see below note): American Board of Radiology Diagnostic Imaging Physics by the American Board of Medical Physics Diagnostic Radiological Physics by the Canadian College of Physicists in Medicine. NOTE: If not board certified, the medical physicist conducting the performance evaluation will meet ALL of the following requirements: A graduate degree in physics, medical physics, biophysics, radiologic physics, medical health physics, or a closely related science or engineering discipline from an accredited college or university. College coursework in the biological sciences with at least one course in biology or radiation biology, and one course in anatomy, physiology, or similar topic related to the practice of medical physics. Documented experience in a clinical environment with at least 10 CT performance evaluations completed under the direct supervision of a board-certified medical physicist SERVICES Contractor will be responsible for reviewing the department s radiation safety policies and procedures and make any recommendations. Contractor will review all film badge (dosimetry) records to assess if occupational exposure levels are below regulatory limits and make recommendations regarding ALARA (As Low As Reasonably Achievable) guidelines. Annually evaluate radiation dose on four common CT procedures (protocols) submitted by the facility RSO (Radiation Safety Officer). Must verify that CTDIvol (volume computed tomography dose index) for each protocol is within 20% of the CTDIvol displayed on the CT console. Dates, results and verification of measurements must be documented in the final physicist report. Contractor will perform integrity check of all personnel lead shielding devices to include approximately forty-three lead aprons and five thyroid shields. Contractor is responsible for updating and ensuring the Patient Radiation Exposure Monitoring Program is in accordance with FDA and Joint Commission standards. Annually evaluate radiation dose on four common CT procedures (protocols) submitted by the facility RSO (Radiation Safety Officer). Must verify that CTDIvol (volume computed tomography dose index) for each protocol is within 20% of the CTDIvol displayed on the CT console. Dates, results and verification of measurements must be documented in the final physicist report. Annually evaluate image acquisition display monitors (CT and MRI only) and radiology physician display monitors for maximum and minimum luminance, luminance uniformity, resolution, and spatial accuracy. Measurements must be documented in the final physics report. Provide telephone consultation as needed. Physicists will work when scheduled with the Radiology department, and telephone support when needed. Attend at a minimum two quarterly MR/Radiation Safety Committee meetings to review protocols and general radiology practices related to patient safety. CONFORMANCE STANDARDS: Contractor shall provide services and material to ensure that the equipment functions in conformance with the latest requirements of American College of Radiology standards, NFPA-99, Joint Commission, HIPAA, NEC, OSHA, CAP, Federal, state, and Local specifications and requirements as applicable. The equipment shall be maintained such that it meets or exceeds the performance specifications as established in the OEM s technical specifications. DOCUMENTATION/REPORTS: The documentation will include equipment down time and detailed descriptions of the scheduled procedures performed that keep the equipment in accordance with conformance standards. Such documentation shall meet the guidelines as set forth in the Conformance Standards. In addition, each ESR must at a minimum document the following data legibly and in complete detail: Name of Contractor. Name of Physicist who performed services. Contractor Service ESR Number/Log Number. Date, Time (starting and ending), Hours worked for service call. Description of tests performed by. Identification of Equipment to be serviced to include the following: Equipment ID # or EE# from the bar-code, Manufacturer's Name, Device Name, Model#, Serial #, and any other Manufacturer's identification numbers. Itemized Description of Service(s) Performed, including: Labor and Travel, Parts (with part numbers) and Materials and Circuit Location of problem/corrective action. Signatures from the following: Physicist performing services described. VA Employee who witnessed service described. Equipment downtime, calculated in accordance with Conformance Standards. NOTE: ANY ADDITIONAL CHARGES MUST BE APPROVED BY THE CO BEFORE SERVICE IS COMPLETED! REPORTING REQUIREMENTS: The contractor shall report to VA Police to "check-in" upon arrival and prior to performance of work under this contract or contact the Program point of contact (POC) prior to remote access. This check-in is mandatory and can be accomplished in person or by phone contact. When the service(s) is/are completed, the FSE shall document the services rendered on a legible ESR(s). The Physicist shall be required to check out with the Biomedical Engineering Department or Radiology department and submit the ESR(s) to the Program POC. All ESRs shall be submitted to the equipment user for an "acceptance signature" and to the Program POC for an "authorization signature." If the Program POC is unavailable, a signed accepted copy of the ESR will be sent to the Program POC within 5 business days of work completion. FAILURE TO COMPLY, EITHER IN WHOLE OR IN PART, WITH EITHER THE NOTIFICATION OR ESR REQUIREMENTS WILL BE DEEMED SIGNIFICANT NON-COMPLIANCE WITH THE CONTRACT AND MAY BE JUSTIFICATION FOR TERMINATION OF THE CONTRACT. ADDITIONAL CHARGES: There will be no additional charge for time spent at the site during, or after the normal hours of coverage awaiting the arrival of additional physicist. REPORTING REQUIRED SERVICES BEYOND THE CONTRACT SCOPE: The Contractor shall immediately, but no later than 24 consecutive hours after discovery, notify the CO and Program POC (in writing), of the existence or the development of any defects in, or repairs required to the scheduled equipment which the Contractor considers he/she is not responsible for under the terms of the contract. The contractor shall furnish the CO and Program POC with a written estimate of the cost to make necessary repairs. CONDITION OF EQUIPMENT: The contractor accepts responsibility for the equipment described herein, in "as is" condition. Failure to inspect the equipment prior to contract award will not relieve the contractor from performance of the requirements of this contract. COMPETENCY OF PERSONNEL SERVICING EQUIPMENT: Each respondent must have an established business, with an office and full-time staff. The staff includes a "fully qualified" Physicist and a "fully qualified" Physicist who will serve as the backup. The Physicist performing the evaluations must have board certification by one or more of the following (if not board certified, see below note): American Board of Radiology Diagnostic Imaging Physics by the American Board of Medical Physics Diagnostic Radiological Physics by the Canadian College of Physicists in Medicine NOTE: If not board certified, the medical physicist conducting the performance evaluation must meet ALL of the following requirements: A graduate degree in physics, medical physics, biophysics, radiologic physics, medical health physics, or a closely related science or engineering discipline from an accredited college or university. College coursework in the biological sciences with at least one course in biology or radiation biology, and one course in anatomy, physiology, or similar topic related to the practice of medical physics. Documented experience in a clinical environment with at least 10 CT performance evaluations completed under the direct supervision of a board-certified medical physicist. TEST EQUIPMENT: Prior to commencement of work on this contract, the contractor shall make available if requested a copy of the current calibration certification of all test equipment that is to be used by the contractor in performing work under the contract. This certification shall also be provided on a periodic basis when requested by the VA. Test equipment calibration shall be traceable to a national standard.

More opportunities from Department Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)

Same awarding agency

NAICS: 561730
New
Federal
S218--Snow Removal Services Wilmington VAMC
Solicitation # 36C24427Q0O12
Solicitation 36C24427Q0012 is a combined synopsis and request for quote for snow removal and deicing services at the Wilmington VAMC in Delaware. This is a five-year Indefinite Delivery/Indefinite Quantity (IDIQ) contract with an anticipated period of performance from December 1, 2026, through November 30, 2031. The contract has a minimum guarantee of 5,000 dollars and an estimated maximum value of 500,000 dollars, with funds obligated via individual task orders. The procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 561730. The scope of work includes clearing all levels of a multi-level parking garage, stairwells, entrances, and exposed ramps, with a requirement that all areas be cleared by 6:00 AM EST following overnight snowfall. Specific chemical restrictions are in place, prohibiting rock salt in the garage and requiring the use of garage-friendly chemicals such as sodium acetate, potassium acetate, or calcium magnesium acetate. The contractor must provide an on-site supervisor for every operation and ensure personnel wear OSHA-required PPE and high-visibility vests. Performance will be evaluated based on a Quality Assurance Surveillance Plan, and the award will be based on a comparative evaluation of technical capability and past performance, as well as price. Offerors must be registered in the System for Award Management and submit their quotes via email to the designated contract specialist. Submissions must include a technical document not exceeding 20 pages, firm fixed pricing for all line items, and three examples of past performance for similarly scoped work. Invoices are to be submitted electronically in arrears upon job completion and are due within 30 days. Compliance with applicable wage and hour laws and limitations on subcontracting are mandatory for the prime contractor.
Landscaping Services

POSTED

2 days ago

DEADLINE

in 4 days
View Details
NAICS: 811210
New
Federal
J065--Notice of Intent to Sole Source Maintenance of Alaris Infusion Pumps
Solicitation # 36C24427Q0040
The Department of Veterans Affairs has issued a notice of intent for a single, Firm-Fixed Price contract to provide annual maintenance and support services for the Alaris System software and components at the Butler Healthcare Care Center in Butler, Pennsylvania. The primary objective is to secure a post-warranty, full maintenance agreement for the Guardrails software package and to update the network configuration by adding a new range of IP addresses via the VA Altoona server. The period of performance consists of a one-year base period after receipt of order, with four additional one-year option periods available at the government's discretion. The scope of work includes the installation of the latest software versions for Guardrails Suite MX and Alaris Systems Manager, as well as comprehensive technical support and clinical services. Key deliverables include quarterly infusion analytics reports, technical telephone support, monthly web-based training, and annual on-site visits from both technical service and RN clinical consultants. The contractor must ensure compliance with Federal Information Processing Standards (FIPS) 140-2 for the Alaris Packet Control Unit wireless module and adhere to BD's federal terms and conditions. Financial administration will be handled through monthly invoicing for maintenance and support fees.
Electronic and Precision Equipment Repair and Maintenance

POSTED

2 days ago

DEADLINE

in 4 days
View Details
NAICS: 236220
New
Federal
Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC
Solicitation # 36C24426R0088
Solicitation 36C24426R0088 is a firm fixed price request for proposal issued by the Department of Veterans Affairs for the Upgrade Substation Building 2 Phase 1 project at the Corporal Michael J. Crescenz Medical Center in Philadelphia, Pennsylvania. This project is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 236220, with an estimated value between 5 million and 10 million dollars. The primary objective is to replace two 29 year old electrical substations with new 480/277V substations, each featuring a 1500 kVA transformer, to increase electrical capacity for current and future facility needs. To ensure continuous medical center operations and minimize service outages, the contractor must install a temporary 480/277V substation with a 1500 kVA transformer, which will remain on site as a spare upon project completion. The period of performance has been extended to 1,000 calendar days from the Notice to Proceed. Proposals are due by November 20, 2026, at 4:00 PM EST and must be submitted in separate administrative/price and technical volumes. Award will be based on a Best Value Tradeoff evaluation focusing on technical approach, past performance in occupied hospitals, key personnel qualifications, safety and risk management, quality control, and procurement strategy. Key requirements include strict adherence to Infection Control Risk Assessment protocols, the provision of 100 percent performance and payment bonds, and compliance with the Davis-Bacon Act and Buy American requirements.
Commercial and Institutional Building Construction

POSTED

2 days ago

DEADLINE

in 22 days
View Details
NAICS: 236220
New
Federal
Z2DA--FY26 NRM 460-20-004 | Tuckpointing FY26 | NCO 4 Construction East (VA-26-00060656)
Solicitation # 36C24426B0018
Solicitation 36C24426B0018 is an Invitation for Bid issued by the Department of Veterans Affairs Network Contracting Office 4 for professional tuckpointing and masonry repair services at the Wilmington VA Medical Center in Delaware. This project is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220. The scope of work involves the repair, replacement, and rework of deteriorated exterior masonry and caulking systems across ten buildings on the campus while the medical center remains fully operational. The estimated magnitude of construction is between 2,000,000 and 5,000,000 dollars, with a required period of performance of 270 calendar days from the Notice to Proceed. The contract will be awarded to the responsive and responsible bidder offering the lowest price. Bidders must provide a bid guarantee and are required to submit unit prices for repointing per linear foot and individual brick replacement. Key compliance requirements include adherence to the Davis-Bacon Act, the Buy American Act, and ADA standards, as well as the submission of a site-specific safety plan and performance and payment bonds. The government will conduct pre-final and final acceptance inspections to verify that all work meets federal, state, and local codes and VA specifications. Payment will be processed electronically through the VA Electronic Invoice Presentment and Payment System.
Commercial and Institutional Building Construction

POSTED

2 days ago

DEADLINE

in 7 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS