Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Agriculture was posted on August 23, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

HAZMAT/Flammable Materials Storage Unit

Closed
1282B124Q0102Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 332311
New
Federal
Solicitation_S-280C/G Vehicle Mounted Shelter
Solicitation # W912CH-26-R-A096
The Army Contracting Command - Detroit Arsenal is soliciting proposals for a five-year, Firm-Fixed-Price, Indefinite Delivery/Indefinite Quantity contract for the manufacture and delivery of four variants of the S-280C/G Vehicle Mounted Shelter. These lightweight tactical shelters, available in shielded and unshielded configurations with or without mobilizer adapter kits, are designed to protect personnel and sensitive electronic equipment from demanding field environments and electromagnetic interference. The contract has a minimum guaranteed value of 100,000 dollars and a maximum estimated ceiling of 4,000,000 dollars. This is a 100 percent small business set-aside under NAICS 332311. Award will be based on a best-value tradeoff process, weighing technical factors and price with approximately equal importance. Technical evaluation focuses on EMI shielding design and manufacturing processes. Mandatory requirements include First Article Testing and strict adherence to the government-owned Technical Data Package and ASTM E1975-22 standards. The contractor must also provide technical publications and provisioning data. Deliveries are FOB Destination, with an estimated distribution of 75 percent CONUS and 25 percent OCONUS, and a maximum sustained production rate of 20 shelters per month. Proposals must be submitted electronically by October 30, 2026.
W6QK Acc- Dta

POSTED

about 18 hours ago

DEADLINE

in 10 days

General Info

Contract Value

$29,265

NAICS

332311 - Prefabricated Metal Building and Component Manufacturing

Place of Performance

Keystone, CO, 80435, USA

Set-Aside

SBA

Awardee

TEAL, LLC

Award Issued Date

Documents

3

Amendment 0001 to Solicitation 1282B124Q0102

PDF, High priority: read this first1 page · amendment
High

Amendment 0002 to Solicitation 1282B12Q0102

PDF, High priority: read this firstamendment
High

Solicitation 1282B124Q0102 - HAZMAT/Flammable Materials Storage Unit

PDF, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseClosed
Posted

Solicitation

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Agriculture → Ocp-Pod-Acq-Mgmt-Branch-Ftc USDA
Contacts1 person available
OfficeFORT COLLINS, CO, 80521, USA
Office AddressFORT COLLINS, CO, 80521, USA
Contacts
Jason Bologna

Full Description

Show more
Dillon Ranger District of the White River National Forest requires the purchase of a HAZMAT/Flammable Materials Storage Unit that meets the needs of the government to safely and appropriately store flammable materials. The required HAZMAT/Flammable Materials Storage Unit must meet the needs of the government in accordance with the stated minimum specifications of this solicitation. Required delivery is 90 days after award of contract. Contractors must include delivery lead time with their quote. Contractors unable to meet the 90 day delivery requirement also should submit their actual lead time for consideration. HAZMAT/Flammable Materials Storage Unit: Provide and deliver one pre-engineered, portable hazardous material storage unit to selected location. This unit shall be FM approved and suitable for storage of combustible, flammable liquids and other hazardous materials. Unit shall not require specific foundations or supports. All materials used in construction must be new and unused. Use of wood in construction is unacceptable. Manufacturing quality compliance shall be in accordance with ASTM, AISI, and AWS materials and fabrication standards. The unit must meet the model building codes, model fire codes, safety and environmental regulations: Current Additions: - International Building Codes (IBC) - BOCA National Building Code - Standard Building Code - Uniform Fire Code - BOCA National Fire Prevention Code - Standard Fire Prevention Code - BOCA Building Officials and Code Administrators - National Electric Code (NEC/NFPA 70) - OHSA (29 CFR) - EPA (40 CFR) - California Administrative Code - NFPA - National Fire Protection Assoc. - AWS - American Welding Society - AISC - American Institute of Steel Construction - ANSI - American National Standards Institute - ASTM - American Society for Testing and Material - USPC - United States Product Code Flammable Materials Storage Unit Minimum Specifications: - 2-Hour Fire-rated HazMat Storage Unit with dimensions of approximately 14' x 8' x 8.5' LxDxH. - Steel Shelving with 2" lip installed along entire back wall, Seismic, Free Swinging. - Interior LED Lighting (Class I Div I - 300 watts maximum) - solar or battery powered. - Loading Ramp with approximate dimensions: 54in x 60in (W-L), Built of no less than 10-gauge steel. - Non-combustible exterior, roof, and interior walls (not insulated for temp. control). - Roof pitched for rainwater runoff. - Carbon steel drum platform (steel grating) in removable sections for easy sump access. - Minimum of 300-gallon capacity sump. No mechanical fasteners used. - Spill containment sump utilizes continuously welded heavy gauge steel sheets. - One Set of Double Doors on front of building. - Two-point latching on the inactive leaf and three points on the active leaf. - Interior door release and hold open device. - Interior and exterior surfaces coated with a corrosion resistant, two-part epoxy primer and urethane topcoat. Designed for Outdoor Use. - All metal-to-metal surfaces prime painted prior to assembly for added weather protection. - Static grounding and bonding angles. - Include 8' long grounding rod and cable - Shipped loose for customer installation. - Hazard labeling / placards. - 4" riser for forklift and / or crane slings for easy placement or sump inspections. - Four hold-down angles for bolting to foundation (Seismic and Wind Load anchoring). - Passive ventilation in accordance with NFPA 30 to ensure six (6) air changes per hour. - Air inlet vents equipped with louvers and screens to provide air flow while preventing wildlife entry. - Vertical shutter, 3-hour fire rated, held open by 165 F fusible link. - Include manufacturer's warranty. *****08/21/2024 *****(UPDATED) - Amendment 0001 to solicitation #1282B124Q0102. The purpose of this amendment is in response to questions regarding this solicitation. Question 1: Is hold open device just a steel hold open or fusible link door closer? Answer: Hold open device for doors shall be standard hold open or latch. Question 2: Does the light need to be class 1, div 1 or would class 1, div 2 work? Answer: Lighting and electrical system shall meet National Electrical Code - NEC 500.5(B)(1) standards. Interested contractors shall review the attached SF30 and acknowledge receipt of this amendment by returning a signed copy of the SF30 to the listed point of contact of this solicitation. *****08/23/2024 *****(UPDATED) - Amendment 0002 to solicitation #1282B124Q0102. The purpose of this amendment is in response to additional questions regarding this solicitation, and to inform the public that questions regarding this solicitation must be received by the point of contact no later than 3:00 PM EDT on 08/28/2024. Question 3: Does the solar powered light need a battery as well to work 24/7 or does the light only need to work during the day? Answer: Solar powered lighting must be operable during daytime and nighttime hours. Interested contractors shall review the attached SF30 and acknowledge receipt of this amendment by returning a signed copy of the SF30 to the listed point of contact of this solicitation.

More opportunities from Department Of Agriculture → Ocp-Pod-Acq-Mgmt-Branch-Ftc USDA

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS