Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on May 4, 2015. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

HEPA Vaccum System

Closed
F1Q2EM5105AQ01_SourcesSought_HEPAVaccumSystemFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238290
New
Centennial JCC Panic Hardware Services (Electrical Room Egress Doors)
Solicitation # Panic Hardware (Electrical Room Egress Doors)
Management & Training Corporation (MTC) is soliciting bids for the installation of commercial-grade panic hardware on electrical room egress doors at the Centennial Job Corps Center in Nampa, Idaho. The scope of work includes conducting site surveys to verify door dimensions and fire ratings, procuring Grade I heavy-duty panic bars, exterior trim, rim cylinders, strikes, and door closers, and performing installation and testing. All work must adhere to NEC 2023 Article 110.26(C)(3), NFPA 101 Life Safety Code, and ADA standards. To ensure fail-safe operation, contractors must perform at least 10 consecutive cycle tests on all installed hardware. This is a fee-for-service subcontracting opportunity open to small businesses, including certified VOSB, SDVOSB, WOSB, and HUBZone entities under NAICS code 238290. Bidders must be licensed in the State of Idaho and provide three references for similar projects. Required submission documents include a completed bid sheet with lump sum and individual deficiency pricing, a W-9, a self-certification form, and acceptance of terms and conditions. All bids must be submitted via email to Sandra Clore by December 1, 2026, at 3:00pm MST. The contract is subject to various federal regulations, including the Davis-Bacon Act for prevailing wage rates and fringe benefits, as well as FAR clauses regarding Buy American preferences and combating trafficking in persons. Contractors are required to comply with DOL records management, mandatory training, and privacy breach notification requirements. Payment will be issued upon the submission of invoices for materials and services that have been delivered and accepted by MTC. Final inspection and acceptance will occur at the MTC designated point of delivery.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in about 1 month
NAICS: 238290
New
SLED
Kitchen Elevator Upgrade and Repair Service - NHSP-M
Solicitation # RFP NHDOC 2027-07
The New Hampshire Department of Corrections is soliciting proposals for a firm fixed price or not-to-exceed contract to provide comprehensive upgrades and repairs for a 1985 Dover Corporation passenger elevator at the New Hampshire State Prison for Men. The elevator, which serves two floors of the kitchen and has a 4,000-pound capacity, requires a new power unit including the motor, hydraulic valve, pump, oil reservoir, and muffler, as well as the installation of four security key switches and eight keys. All work must be performed by New Hampshire licensed professionals and comply with all local, state, and federal elevator codes, with final safety test results submitted to the New Hampshire Department of Labor. The project is expected to start in January, with a final completion deadline of June 30, 2027. Proposals are due by 2:00 PM EST on November 13, 2026, and must be submitted as separate sealed technical and cost proposals. Evaluation is based on a combined score of the technical proposal, which focuses on organizational experience, correctional facility expertise, and approach, and the cost proposal. Award selection may involve a Best and Final Offer process. Selected vendors must maintain significant insurance coverages, including commercial general liability of at least 1 million dollars per occurrence, and adhere to strict correctional facility security protocols, including tool inventories and compliance with PPD 371. Payment will be issued within 30 days of receiving approved monthly itemized invoices.
Department Of Corrections

POSTED

about 3 hours ago

DEADLINE

in 15 days
NAICS: 238290
New
Federal
J039--561A4-25-500 Elevator Repair Building 6 and 53
Solicitation # 36C24226R0097
Solicitation 36C24226R0097 is a Request for Proposal issued by the Department of Veterans Affairs for the emergency upgrade and modernization of four elevators at the VA New Jersey Healthcare System Lyons Campus, specifically targeting one passenger elevator in Building 6 and one service and two passenger elevators in Building 53. The scope of work requires the contractor to provide all labor, materials, and supervision to install non-proprietary microprocessor-based control systems, new geared machines, car operating panels with braille markings, hall fixtures at ADA compliant heights, and complete shaft wiring. All work must adhere to current safety codes, including fire recall features and door lock monitoring, and comply with the Davis-Bacon Act for prevailing wage rates. This procurement is a Service-Disabled Veteran-Owned Small Business set-aside under NAICS code 238290. To be eligible, the prime contractor must be a licensed elevator maintenance company with a full-time mechanic on staff and a clean safety record, certifying no more than three serious, one repeat, or one willful OSHA or EPA violation in the last three years. Proposals are evaluated based on technical capability, past performance, and price, with a requirement to submit a current Experience Modification Rate (EMR) and certifications for the Buy American Act and limitations on subcontracting. Following several extensions to accommodate requests for information, the final deadline for proposal submission is 1:00 PM on Thursday, October 29, 2026.
242-NETWORK Contract Office 02 (36C242)

POSTED

about 7 hours ago

DEADLINE

in 22 days

General Info

NAICS

238290 - Other Building Equipment Contractors

Place of Performance

Dover AFB, DOVER, DE, 19902, USA

Set-Aside

NONE

Documents

2

HEPA_Vacuum_Statement_of_Need.docx

DOCX

Sources_Sought_HEPA_Vacuum.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4497 436 Cons Lgc
Contacts1 person available
OfficeDOVER AFB, DE, 19902-5016, USA
Office AddressDOVER AFB, DE, 19902-5016, USA

Full Description

Show more
This is a sources sought synopsis seeking information of potential firms (nationwide) that have an interest in submitting as a prime contractor, a proposal for the following description: The project consists essentially of, but is not limited to, Contractor shall provide all labor, tools, and supervision required to provide and install HEPA Vacuum System in accordance with attached Statement of Need. We are requesting that all interested and qualified firms respond to this sources sought notice with a capability statement similar to your marketing package used in the everyday course of doing business. Oral communications ARE NOT acceptable in response to this notice. The Government will utilize the following information in determining acquisition strategy: (1) Summarize how your company is uniquely capable and qualified to handle this type of project; (2) Summarize projects completed similar to the project outlined above. The list of relevant projects may include names of the project team members and firm, point of contact (contracting officer and COR/inspector) with titles, phone and fax numbers, project scope, and type of contract; (3) A statement of your current business size status under the NAICS code 423830 - Industrial Machinery and Equipment Merchant Wholesalers. In your response, also indicate whether you are a HUBZone small business concern, service- disabled veteran-owned small business firm, 8(a) contractor, small business firm, women-owned small business firm, or large business firm. The information above must be submitted in written format via e-mail to contact@example.gov and contact@example.gov. This Sources Sought is an advance notice for information and planning purposes only and is not a solicitation. In order to receive an award from any resultant solicitation, should one be issued, the successful offeror must be registered and active in System for Award Management (SAM). The SAM website is: https://www.sam.gov/. The information/capability statement must be received not later than 18 May 2015. This sources sought notice should not be construed in any manner to be an obligation to issue a contract, or result in any claim for reimbursement of costs for any effort you expend in responding to this request. No solicitation is currently available. OMBUDSMAN (APR 2014) (a) An ombudsman has been appointed to hear and facilitate the resolution of concerns from offerors, potential offerors, and others for this acquisition. When requested, the ombudsman will maintain strict confidentiality as to the source of the concern. The existence of the ombudsman does not affect the authority of the program manager, contracting officer, or source selection official. Further, the ombudsman does not participate in the evaluation of proposals, the source selection process, or the adjudication of protests or formal contract disputes. The ombudsman may refer the interested party to another official who can resolve the concern. (b) Before consulting with an ombudsman, interested parties must first address their concerns, issues, disagreements, and/or recommendations to the contracting officer for resolution. Consulting an ombudsman does not alter or postpone the timelines for any other processes (e.g., agency level bid protests, GAO bid protests, requests for debriefings, employee-employer actions, contests of OMB Circular A-76 competition performance decisions). (c) If resolution cannot be made by the contracting officer, the interested party may contact the Center/MAJCOM/DRU or AFISRA ombudsmen, Mr. Gregory Oneal, HQ AMC/A7K, 507 Symington Drive, Scott AFB IL 62225-5022, +1 (555) 000-0000, fax +1 (555) 000-0000, email: contact@example.gov. Concerns, issues, disagreements, and recommendations that cannot be resolved at the Center/MAJCOM/DRU or AFISRA level, may be brought by the interested party for further consideration to the Air Force ombudsman, Associate Deputy Assistant Secretary (ADAS) (Contracting), SAF/AQC, 1060 Air Force Pentagon, Washington DC 20330-1060, phone number +1 (555) 000-0000, facsimile number +1 (555) 000-0000. (d) The ombudsman has no authority to render a decision that binds the agency. (e) Do not contact the ombudsman to request copies of the solicitation, verify offer due date, or clarify technical requirements. Such inquiries shall be directed to the Contracting Officer. (End of clause) Points of Contact TSgt Nathan Filson, Contract Specialist contact@example.gov Comm: +1 (555) 000-0000 TSgt Melvin Mitchell, Contracting Officer/Team Lead contact@example.gov Comm: +1 (555) 000-0000 STATEMENT OF NEED NILFISK 3707 (or Equal) HEPA VACUUM SYSTEM 1.0 DESCRIPTION OF NEED 1.1 Corrosion Control currently uses a Nilfisk GB-1133 HEPA Vacuum system during sanding operations in order to assist in capturing and preventing the spread Hexavalent Chromium contamination generated in the paint removal process for refurbishing C-5 and C-17 aircraft parts. The new HEPA Vacuum system must be able to integrate into the current system via the 4 inch inlet. 1.1.1 We require the following item (or Equal) in order to safely continue operation: Nilfisk 3707 Hepa Vacuum 460V 518cfm@92in/H2O. 1ea Reverse Purge Cartridge filter kit. 1ea Polyliner Adapter kit 3707/3907/3997. 1ea 100MM inlet Coupler for 4" header hose. 1ea Polyliner Bags 46 Gal 1 PK 3707/3907/3997. 10ea 1.1.2 The below specs are the minimum this machine should meet in order to provide the optimum performance for our sanding booth: - CFM- 600 CFM - Water lift - 92.3" (controlled) 187" sealed inlet - Noise in dba - 78DBA - Voltage - 460 (3 phase) - Capacity - 46 gallons - Filter Surface Area - 75.36 ft2 (4) Cartridges - Current Max - 15.1 amps (460V) - HEPA Efficiency -99.995@.018 microns - Downstream HEPA Surface Area 186.22 ft2 - Dimensions LxWxH - 63x31.5x71.3 - Weight w/o cartridges - 672 lbs. - Protection Class - IP55 - Inlet diameter - 4" (100mm)

More opportunities from Department Of Defense → FA4497 436 Cons Lgc

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS