Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Defense was posted on June 7, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

HLD Safety 480VAC Outlets

Closed
W912EF-22-Q-0159Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Contract Value

$49,440

NAICS

335931 - Current-Carrying Wiring Device Manufacturing

Place of Performance

Burbank, WA, 99323, USA

Set-Aside

SBA

Award Issued Date

Documents

1

B.08.02+Solititation+W912EF-22-Q0159.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → US Army Engineer District Walla Wal
Contacts2 people available
OfficeWALLA WALLA, WA, 99362-1876, USA
Office AddressWALLA WALLA, WA, 99362-1876, USA

Full Description

Show more
TECHNICAL SPECIFICATIONS Safety Outlet Disconnect 1.0 Summary of Scope To furnish new 480VAC 30-amp safety outlets with a disconnect improve safety while working in the Powerhouse. These new safety outlets will benefit the project in the fact that ARC Flash Hazards will be greatly reduced by using new Safety items technology. These Outlets shall be supplied in accordance with the following specifications for the U.S. Army Corps of Engineers, Walla Walla District at Ice Harbor Lock and Dam, Burbank, Washington. The vendor shall supply new 480VAC 30-amp safety outlets with a disconnect, watertight locking plug ends, and must be delivered in new condition while meeting the requirements of the Buy American Act. . 2.0 Specifications 2.1 480VAC Safety disconnect outlet Voltage rating must be 600V RMS Dielectric strength must be able to withstand 1000V AC for 1 minute Must have certified interrupting rating of full rated current Must be 3 pole 4 wire receptacle The cord plug must not be able to be removed until the switch is turned off Must have a lockable RED handle that meets OSHA regulation for lockout tagout Must be pre-wired IEC pin and sleeve receptacle Housing must be NEMA type 4X, 12 and IP67 rated Must have mounting feet that are fully adjustable Mounting holes height must not exceed 11.5 center to center Mounting holes width must not exceed 7.5 center to center Mounting holes must be able to accept 5/16 diameter bolt All gaskets must be neoprene or Chloroprene Hubble HBL430MI7W or approved equal 2.2 480VAC Watertight locking plug Plug must be watertight IEC pin and Sleeve 3 pole 4 wire Voltage rating must be 600V RMS Dielectric strength must be able to withstand 3000V AC for 1 minute Must have certified interrupting rating of full rated current Plug must be IP67 rated gasket must be neoprene or Chloroprene must have a closure cap Must have cord clamp and locking ring Must have liquid tight adapters Housing must be RED in color Hubble HBL430P7W or approved equal 3.0 SCHEDULE All components shall be delivered no later than One hundred twenty (120) days after the receipt of contract award. Contractor shall make prior arrangements with the Government personnel at site to receive and unload the equipment. 4.0 Submittals and Requirements 4.1 Vendor Product Sheet and Drawings The vendor shall provide cut sheets with the dimensions, drawings, etc., with the quote for the Government to review for technical acceptability. All quoted information shall be sent to the Contracting Officer. All quotes shall be of sufficient in detail to show conformance to the specifications. Failure to provide acceptable proof of conformance or failure to meet the requirement of the specifications may result in disqualification 5.0 DELIVERY All items shall be delivered F.O.B. Destination to Ice Harbor Project. The contractor is responsible for packing and shipping components in a manner that will ensure undamaged and complete arrival to Ice Harbor Dam. Normal working hours at Ice Harbor Dam are 6:30 a.m. to 5:00 p.m., Monday through Thursday, excluding holidays. The delivery shall arrive between 7:00 a.m. and 3:00 p.m. during normal working days. Delivery made outside of this time slot will not be accepted. This is to allow for unloading and inspection. The delivery shall be made to the south side of the dam. The delivery address is as follows: Ice Harbor Dam 2763 Monument Drive Burbank, Washington 99323 Contractor shall make prior arrangements with the Government personnel at site to deliver and unload the equipment.

More opportunities from Department Of Defense → US Army Engineer District Walla Wal

Same awarding agency

NAICS: 332812
New
Federal
Dworshak Skeleton Bay Draft Tube Bulkhead Rehabilitation
Solicitation # W912EF27QA002
The US Army Corps of Engineers, Walla Walla District, is soliciting a firm fixed price contract for the rehabilitation of twelve draft tube bulkheads and associated seal keeper bars at Dworshak Dam. This total small business set-aside project requires the contractor to provide all personnel, materials, equipment, and supervision necessary for the pickup, dry-blast cleaning to white metal, weld repair, and new coating application of the bulkheads. The work must be performed in accordance with strict industry standards, including AWS D1.1 for welding and SSPC SP 5 / NACE No. 1 for surface preparation. Deliverables are scheduled across multiple units, with specific return dates such as January 23, 2027, for Unit 4 and April 19, 2027, for Unit 5. The contractor must be a certified SSPC QP 3 painting contractor or hold an AISC Complex Coatings endorsement and provide a third-party certified coatings inspector at the SSPC-PCI Level 2 or NACE CIP Level 2. Quality assurance is paramount, requiring detailed inspection reports for each bulkhead and the use of magnetic flux thickness gages per ASTM D7091. The government reserves the right to conduct quality assurance inspections at the contractor's facility. Proposals are due by October 30, 2026, and will be evaluated based on price and other factors to determine the most advantageous offer. All shipping is required to be FOB destination to the Dworshak Project Office in Ahsahka, Idaho.
Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers

POSTED

5 days ago

DEADLINE

in 10 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS