Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Health And Human Services was posted on June 2, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Hospital Beds & Equipment - Potential Equivalents

Closed
BN-GSUT2-20263146Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Indian Health Service, Gallup Service Unit is conducting market research to identify potential equivalents for four specialized medical beds and a wall-mounted vital signs monitoring system, all intended for use in healthcare facilities serving Native American communities. The equipment includes the Progressa+ ICU Bed, Centrella Smart+ Bed, Affinity 4 Birthing Bed, and Compella Bariatric Hospital Bed, each requiring advanced clinical features such as integrated patient scales, nurse call system compatibility with Hillrom, wireless connectivity, X-ray sleeves, and O₂ tank holders for size E tanks. The Welch Allyn Vital Signs Monitor Wall Mount System must function as a fully integrated diagnostic platform with built-in otoscope, ophthalmoscope, non-invasive blood pressure, pulse oximetry, temperature, and pulse rate monitoring, designed for adult, pediatric, and neonatal use, featuring a touchscreen interface, alarm systems, and data export capabilities via Ethernet, USB, or wireless means. All equipment must meet FDA clearance and recognized medical electrical safety standards. This effort is conducted under a Buy Indian Act set-aside, mandating that responders demonstrate Native American ownership and qualify as an Indian Economic Enterprise under HHSAR 326.601 and 25 U.S.C. 47, requiring completion of the IHS IEE Representation Form. Respondents must be registered in SAM.gov, provide a detailed company profile including UEI, ownership type, socio-economic certifications, and capability statements supported by past performance records, and submit comparative analyses of proposed equivalents against the specified salient characteristics. All submissions must be received by 10:00 AM MDT on June 9, 2026, via email to the Contract Specialist with the required subject line; no telephone inquiries or feedback will be provided, and this notice is strictly for market research with no financial obligation to respondents. The NAICS code for this requirement is 339113 with a small business size standard of 800 employees, and performance is expected in Gallup, New Mexico.

General Info

Indian Health Service seeks advanced hospital beds and vital signs monitors, requiring FDA-compliant product information.

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Gallup, NM, 87301, USA

Set-Aside

NONE

Documents

1

IHS+IEE+Representation+Form_Jan+2022_508+Compliant.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Health And Human Services → Navajo Area Indian Health Svc
Contacts1 person available
OfficeWINDOW ROCK, AZ, 86515, USA
Office AddressWINDOW ROCK, AZ, 86515, USA
Contacts

Full Description

Show more

Sources-Sought Notice


The Indian Health Service, Gallup Service Unit is issuing this sources-sought notice (SSN) to identify potential equivalents for the following items:



Progressa+ ICU Bed (Product No. P 7500)


Salient Characteristics:


Advanced ICU bed with integrated pulmonary therapy features


Continuous lateral rotation therapy (CLRT) capability


Integrated patient scale and bed exit alarm


Advanced pressure injury prevention surface


Electric controls with backup battery


Integrated nurse call system compatibility (Hillrom)


Bed exit alerts routed to nurse call system


Patient call interface via side rails/handset


Connectivity with existing nurse call infrastructure


Meets FDA and hospital-grade safety standards Caregiver Pendant


Includes multiple integrated clinical and support modules


Core Features & Modules


Patient Care & Therapy


Microclimate management surface


Rotation therapy


Percussion & vibration therapy


Chair egress positioning


Mobility & Handling


IntelliDrive powered transport


Permanent IV pole


Monitoring & Convenience


In-bed scale


Nurse call integration (universal TV & lighting control)


Wi-Fi module (if applicable)


X-ray sleeve


O₂ tank holder size E tanks.




Centrella Smart+ Bed (Product No. P7900)


Salient characteristics:


Medical-surgical smart bed with fall prevention technology


Integrated patient monitoring (bed exit, positioning alerts)


Pressure redistribution surface


Built-in weight scale system


Ergonomic design for staff safety and patient mobility


Full nurse call system integration (Hillrom)


Bed status alerts (exit, brake, siderails) transmitted to nurse call system


Patient call functionality integrated into bed controls


Real-time alerts to staff communication devices (if supported)


Connectivity for data integration (EMR/nurse call interoperability preferred)


Permanent IV pole


Monitoring & Convenience


In-bed scale


Nurse call integration (universal TV & lighting control)


Wi-Fi module (if applicable)


X-ray sleeve


O₂ tank holder size E tanks.




Affinity 4 Birthing Bed


Salient characteristics:


Labor, delivery, recovery (LDR) capable bed


Adjustable positioning for delivery and postpartum care


Removable foot section for delivery


Support for maternal mobility and comfort


Emergency positioning capabilities


Full nurse call system integration (Hillrom)


Patient call access from bed controls


Integration with unit nurse call system for alerts


Permanent IV pole


Monitoring & Convenience


In-bed scale


Nurse call integration (universal TV & lighting control)


Wi-Fi module (if applicable)


X-ray sleeve


O₂ tank holder size E tanks.




Compella Bariatric Hospital Bed


Salient characteristics:


Weight capacity ≥ 500 lbs


Integrated air surface for pressure injury prevention


Expandable width frame


Built-in scale and safety alarms


Full nurse call system integration (Hillrom)


Bed alerts and safety alarms routed to nurse call system


Patient communication interface accessible from bed


Permanent IV pole


Monitoring & Convenience


In-bed scale


Nurse call integration (universal TV & lighting control)


Wi-Fi module (if applicable)


X-ray sleeve


O₂ tank holder size E tanks.



Welch Allyn Vital Signs Monitor Wall Mount System (Product No. 85NTVX3-US)


Salient characteristics:


The offered product shall:


-Be a wall-mounted integrated diagnostic and vital signs assessment system designed for ambulatory, outpatient, emergency, and clinical healthcare environments.


-Include integrated diagnostic examination instruments consisting of:


-One otoscope


-One ophthalmoscope


-Rechargeable or powered instrument handles permanently mounted within the wall system.


-Provide integrated vital-sign monitoring capabilities including:


-Non-invasive blood pressure (NIBP)


-Pulse rate


-Pulse oximetry (SpO₂)


-Temperature measurement.


-Support adult, pediatric, and neonatal patient populations.


-Include a color touchscreen display that allows clinicians to view, document, and review patient assessment information.


-Support spot-check and interval monitoring functions for patient vital signs.


-Provide programmable visual and/or audible alarms for monitored parameters.


-Include integrated cord, accessory, and blood pressure cuff management to reduce clutter and maintain an organized patient-care area.


-Support electronic connectivity for transfer of patient data to electronic medical record (EMR/EHR) systems through Ethernet, wireless networking, USB, or equivalent connectivity methods. (Not Necessary)


-Include a minimum of four accessory connectivity ports (USB or equivalent) for peripheral devices and future expansion.


-Operate on standard U.S. commercial power (100–240 VAC, 50/60 Hz) or equivalent.


-Be capable of documenting and storing patient assessment and vital-sign information for clinical review and recordkeeping.


-Include all hardware, mounting components, cables, sensors, accessories, and software necessary for a fully operational wall-mounted diagnostic and vital-signs assessment system.


-Meet applicable FDA clearance requirements and recognized medical electrical equipment safety standards for clinical use.




The applicable North American Industry Classification System (NAICS) code assigned to this requirement is 339113- Surgical Appliance and Supplies Manufacturing with a small business size standard of 800 employees.



THIS IS NOT A SOLICITATION. Information collected from this notice is purely for market research only and will be used to determine the contracting office’s acquisition strategy including brand name restrictions, competition, set asides, and locating Indian-owned economic enterprises.  Submission of any information in response to this market survey is purely voluntary.  The government assumes no financial responsibility for any costs incurred in response to this request for information.


In accordance with FAR 4.203-1(b), offerors and quoters must be registered in System for Award Management at SAM.gov, at the time an offer or quotation is submitted and at time of award.



Submission Instructions: Interested parties are invited to submit a response to this notice by 10:00AM (MDT) on 6/9/2026 to Rodney Brown, Contract Specialist, at contact@example.gov with the subject line “BN-GSUT2-20263146.”  Your submission must include the following information, at a minimum:


  1. Identification of potential equivalents and corresponding manufacturer information.
  2. Statements/descriptions on how potential equivalents compare against each item’s salient characteristics.
  3. Company Profile that includes:  UEI, Name and Address, Primary POC information, business size and type of ownership, socio-economic status/participation such as 8(a), WOSB/EDWOSB, SDVOSB and HUBZone, identification of Native American ownership, SAM.gov representations and certifications, and other related documentation.
  4. A brief statement of the company’s capability that relates to the described government requirement.  Additional demonstration of capability may include current and past performance history for the same or similar requirement, established contracts such as GSA or VA Schedule, etc.
  5. Indian-owned Small Business Economic Enterprises (ISBEEs) and Indian-owned Economic Enterprises (IEEs) must also submit a completed IHS IEE Representation Form (attached) in accordance with HHSAR 326.606-1(b).

Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.

More opportunities from Department Of Health And Human Services → Navajo Area Indian Health Svc

Same awarding agency

NAICS: 339112
Federal
Notice of Intent to award sole source - Compact Robotic Prescription Dispensing System - Tsaile Health Center
Solicitation # THC_0001_2026
The Navajo Area Indian Health Service, Tsaile Health Center, intends to award a non-competitive, sole source purchase order to ScriptPro USA, Inc. for a Compact Robotic Prescription Dispensing System. This procurement, identified by solicitation number THC_0001_2026, is designated under NAICS code 339112. The anticipated period of performance runs from January 1, 2026, to December 11, 2026, with three one-year option periods. ScriptPro is identified as the only uniquely qualified provider because their equipment is already installed and integrated with the RPMS pharmacy computer system; replacing the system would cause significant interruptions to direct patient care and medication dispensing. The system is required to automate the selection, filling, and labeling of prescriptions, supporting at least 225 individual NDC numbers and a throughput of up to 350 prescriptions per hour. Key technical requirements include a direct interface with RPMS and VistA, barcode scanning for drug verification, and compliance with Revised Section 508 and WCAG 2.0 Level AA standards. The contractor is responsible for providing 24/7 support and ensuring the system handles multiple vial sizes while preventing cross-contamination. Invoices for these monthly services must be submitted via www.ipp.gov.
Surgical and Medical Instrument Manufacturing

POSTED

12 months ago

DEADLINE

in 22 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS