Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Award Notice opportunity from National Science Foundation was posted on August 20, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

I-Corps: Translation Potential of a Biomechanics-Driven Optimization of Dental X-Ray Bite Blocks for Enhanced Patient Comfort

Awarded
Grant
Solicitation #
2638228

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

This National Science Foundation I-Corps project focuses on evaluating the translation potential of an engineered dental x-ray bite block designed to increase patient comfort and reduce soft tissue stress. By utilizing a finite element analysis driven computational framework and shape optimization, the technology redistributes contact loading through a combination of a rigid core for positioning accuracy and a compliant outer layer. The goal is to minimize patient discomfort and movement, thereby reducing the need for repeat imaging and improving the overall experience of intraoral radiography. The project employs experiential learning and industry investigation to assess how this biomechanics-driven design can be integrated into the oral healthcare ecosystem. Beyond dental x-rays, the optimization methods used to balance device stability with user comfort may have broader applications for various other medical and dental devices. This award was granted based on the project's intellectual merit and its potential for significant broader impacts on preventive dental care.

General Info

NSF I-Corps project evaluating an engineered dental x-ray bite block for patient comfort.

Contract Value

$50,000

Place of Performance

NY, USA

Set-Aside

NONE

Award Issued Date

Contract End Date

August 31, 2027

Documents

0

No documents available

This contract was awarded without public documents.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

This one is closed. Find the next one like it.

Open contracts like this one, right now:

  • FILE, BONEOpen now, due in 6 days
  • Ergonomic Rotary Task Chair SupplyOpen now, due in 11 days
See open contracts like this

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseAwarded
Posted

Award Notice

Awarded

Contract was awarded

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyNational Science Foundation → Pathways for Translation Section
Contacts1 person available
OfficeN/A

Full Description

Show more
This I-Corps project is based on the development of a dental x-ray bite block designed to enhance patient comfort while maintaining accurate positioning during imaging. Conventional bite blocks may cause discomfort for some patients, particularly those with sensitive oral tissues or conditions that increase oral sensitivity. This technology applies advanced engineering design methods to improve the interaction between the device and oral soft tissues while maintaining clinical performance. Because dental radiographs are among the most common diagnostic procedures in oral healthcare, improving patient comfort has the potential to enhance the patient experience, reduce movement and repeat imaging, and encourage more consistent participation in preventive dental care. This I-Corps project utilizes experiential learning coupled with first-hand investigation of the industry ecosystem to assess the translation potential of an engineering-designed dental x-ray bite block intended to improve patient comfort during intraoral imaging. This technology employs a finite element analysis (FEA)-driven computational framework for optimizing the geometry and material configuration to reduce localized soft tissue contact stresses. The technology applies computational contact mechanics and shape optimization to identify regions of high localized contact stress and generate contoured geometries that redistribute contact loading over a larger area. The bite block combines a rigid core to preserve the dimensional stability and positioning accuracy required for dental radiography with a compliant outer layer intended to reduce localized tissue loading. This may have broader applicability to other dental and medical devices where patient comfort and device usability are important considerations. This award reflects NSF's statutory mission and has been deemed worthy of support through evaluation using the Foundation's intellectual merit and broader impacts review criteria.

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS