Install Centralized Inverter System

Active
F5F3CS6076A001Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The contract involves the engineering, furnishing, installation, and testing of a Centralized Inverter System at the Dial Central Office (DCO), B2407, located at March Air Reserve Base, California. This inverter system is designed to provide AC backup power for critical network equipment and must be a complete turnkey solution. Key technical specifications include an N+1 redundant, modular, hot-swappable, scalable design capable of handling both linear and nonlinear loads with low power factors. Initially, the system will support a 12 KVA load, expandable to at least 16 KVA, with a -48 VDC input from the existing government DC UPS system and delivering a 120 VAC single-phase output. The system includes a 20-position AC output power distribution panel with circuit breakers, manual bypass for maintenance, and an LCD display showing system status and alarms. The equipment can be cabinet-mounted with seismic protection or installed on a provided relay rack, with the contractor determining the preferred configuration. Additionally, the scope includes providing and installing DC power and grounding cables as well as integration with existing government-furnished equipment such as the DC power plant, cable ladder, and relay racks. Contractor responsibilities extend beyond installation to include project management with designated points of contact on-site, safety compliance including accident reporting, adherence to Department of Defense and Air Force security requirements, and safeguarding government property. Quality assurance processes must be established, along with warranty coverage for at least one year on equipment and workmanship. The contractor must provide all necessary manuals, as-built drawings, test and acceptance plans, and coordinate with the government for outage scheduling and final acceptance walkthroughs. The contract also mandates coordination for government support and allows work during normal duty hours, with provisions for after-hours work as needed. Compliance with site-specific rules regarding holidays and security protocols is mandatory, and disposal of unusable materials must be coordinated with the base point of contact.

General Info

Engineering and installation of a scalable, redundant inverter system for March Air Reserve Base network backup.

NAICS

335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing

Place of Performance

670 Meyer Dr. Bldg. 2407 March ARB, CA 92518, MARCH ARB, CA, 92518, USA

Set-Aside

8A

Documents

1

MARCH DCO Centralized Inverter System Budget Estimate

PDF, High priority: read this firstspecifications
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhasePresolicitation
Posted

Presolicitation

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4664 452 Msg Pk
Contacts1 person available
OfficeMARCH ARB, CA, 92518-1716, USA
Office AddressMARCH ARB, CA, 92518-1716, USA

Full Description

Show more
1.0 SCOPE. This SOO defines the requirements for the Contractor to engineer, furnish, install and test (EFI&T) for a Centralized Inverter System in the Dial Central Office (DCO), B2407 for supporting the critical equipment. 2.0 REQUIREMENTS. 2.1 TECHNICAL REQUIREMENTS. The contractor shall provide, install, and make a complete turn-key operation of the Centralized Inverter System. The Contractor shall provide all equipment, tools, materials, supplies, transportation, labor, supervision, management, and other incidentals necessary to meet the requirements as stated in this SOO. The Centralized Inverter System will be used to provide AC backup power for the critical network equipment at the base demarcation location, B2407. 2.1.1 Inverter Systems Requirements: The inverter system shall be N+1 redundant, modular, hot-swappable, scalable and expandable. The system shall be handled linear and nonlinear loads with low power factors that could support lower power equipment such as modems, PC workstations, network switches, router, servers, and transmission equipment system. The inverter system shall support the following requirements and features: - Initially equip to support 12 KVA load and could be expanded up to 16 KVA or beyond as needed - -48 Vdc input using the Government existing DC UPS system - 120 VAC single phase output - Equip with 20-position AC Output power distribution panel w/ circuit breakers - Equip with manual bypass for service and maintenance purposes - Able to provide LCD system status display for system load, AC output measurements voltage, current, frequency, & output power, alarm/failure information, etc. - The system could be equipped with the cabinet or could be mounted on the Government Furnish relay rack, 19" W x 7' H. The Contractor shall specify which option will be used. - If contractor provide cabinet, the cabinet shall be bolted down into the concrete floor for earth quake zone 4 protections in California. Power Cable. The Contractor shall provide and install the DC power cable from the existing DC UPS to the provided Inverter System. Power cable shall be run on top of the existing cable rack. The distance from the Vista Distribution Panel to the inverter system is approximately 48 feet. Grounding. The Contractor shall provide and install the ground to the DCO grounding ring system. The grounding ring system is available along the cable rack system on the top of the relay rack. Ground can present no greater than 5 ohms with #6 AWG green cable. 2.1.2 Government Furnish Equipment (GFE) and supports: 2.1.2.1 The existing DC Power Plant: The contractor shall be used the existing -48 VDC power plant for the DC power input for the inverter system, see figure below for more details. The VISTA Power Distribution Panel is dual (A & B side) configuration. Each side has 20 circuit breakers. Side A and side B have 12 and 19 positions available. 2.1.2.2 The DCO is equipped with cable ladder and cable. 2.1.2.3 Relay Rack: A 19" W x 7' H relay rack (RR201) is available for use, if needed. 2.2 GENERAL REQUIREMENTS. 2.2.1 Safety Requirements. 2.2.1.1 Site Coordination. The Contractor shall meet with the base safety officer immediately upon arrival on site for review of the specific safety requirements prior to installation. 2.2.1.2 Accident/Incident Reporting and Investigation. The Contractor shall record and report all available facts relating to each instance of injury to either Contractor or Government personnel to the Base Safety Office unless otherwise stated in the SOO. The Contractor shall secure the scene of any accident and wreckage until released by the accident investigative authority through the Base POC. If the Government elects to conduct an investigation of the incident, the Contractor shall cooperate fully and assist the Government personnel until the investigation is completed. 2.2.2 Security Requirements. All personnel perform under this contract shall comply with all standard DoD and AF security procedures. All AF information technology system is considered sensitive and proprietary and must be protected. Contractor personnel shall be exposed to information covered under the Privacy Act of 1974, and shall be complied with all applicable safeguarding and handling requirements associated with Privacy Act information. During the performance of this tasking, contractor personnel may be required to access or come into contact with proprietary Government information. Contractor personnel shall not use such information for any purpose other than the performance of this order. 2.2.3 Property Protection. The Contractor shall be responsible for safeguarding all government property provided for contractor use. At the end of each work period, all government facilities, equipment, and materials shall be secured. When not under the direct control of contractor personnel, all government facilities, equipment, and materials utilized by contractor personnel shall be secured. 2.2.4 Quality Assurance. The Contractor shall provide a Quality Control Program for the life of the project. The Contractor's quality assurance evaluator shall assist the Government representative in performing random spot checks and system acceptance tests. 2.2.5 Contractor Requirements. 2.2.5.1 Project Management. The Contractor shall provide a Project Manager (PM) and alternate(s) responsible for contract performance and continuity. 2.2.5.2 Site Point of Contact (POC). The Contractor shall designate the Contractor's on-site team leader and alternate(s) as the Site POC for individual projects in their Site Visit Request Letter. The Site POC or alternate(s) shall be on site during duty hours until project completion. The Site POC shall be the interface for all work site communications with the Government, including quality, safety, and discrepancy matters. 2.2.5.3 Personnel Requirements. All personnel assigned for this project shall be able to read, write, speak, and understand English. 2.2.5.4 Technician Qualifications. The technician(s) assigned to perform on this project shall have a minimum of 2 years of experience on the electrical power system. 2.2.6 Warranty. The Contractor shall provide a one year warranty or manufacturer's standard commercial warranty for any contractor provided equipment, whichever is longer. The warranty shall also include a one year workmanship warranty for the system. The warranty period shall start from the date of system and/or project acceptance. Contractor shall provide written procedures and required information for warranty services at or prior to site acceptance. 2.2.7 Manuals and Practices. The Contractor shall provide a copy of the latest version of operation, installation, and maintenance manuals and practices/users guide for the installed system. 2.3 OTHER REQUIREMENTS 2.3.1 Site Survey. A site survey/walk through shall be conducted per Contractor request. The cost to attend shall be responsibility of the Contractor. Attending the site survey/walk through is at the discretion of the Contractor. 2.3.2 Project Support Agreement (PSA). The Contractor shall provide the government the PSA prior to the installation. The PSA shall specify the agreement of base support and allied support requirements including: electrical, communications, base access, storage, office space, implementation timelines, etc. 2.3.3 Service Outages. The Contractor shall be responsible for preventing any unscheduled (i.e. cutting or disabling any in-service cables or equipment.), Contractor-caused, interruptions of communications capabilities that are properly identified. The Contractor shall coordinate planned outages/service disruption with the base POC in advance of the outage if the implementation necessitates disruption of service, (e.g., communications, electrical, or other utilities). Any damage to government infrastructure due to contractor negligence shall be the responsibility of the contractor and shall be repaired by the contractor at contractor expense prior to completion of the contract. 2.3.4 Installation Schedules. The Government shall coordinate with the Contractor for the installation start. When ready to install, the Contractor shall provide a complete milestone schedule that denotes project activities to include time-phased start and completion dates for the project. 2.3.5 As-Built Drawings. The Contractor shall submit drawings showing the as-built configuration including system equipment/components, system connectivity, and rack/cabinet elevation. 2.3.6 Test and Acceptance/Installation Test Plan. The Contractor shall provide a test plan as to how the system shall be tested to demonstrate to the Government that the system is fully operational and meets or exceeds the specified requirements and that the system is fully ready to be placed into service. The Contractor shall test the system to demonstrate to the Government quality assurance evaluation of the system. These tests shall be accomplished prior to the system being placed into service. 2.3.7 Final Acceptance. The Contractor shall schedule a final project walk-through with the Base POC for final acceptance. 2.3.8 Material Disposal. Dispose the unusable and non-reusable parts/items through the coordination with the base POC. 3.0 GENERAL INFORMATION. 3.1 Place of Performance. The place of performance is March ARB, CA. 3.2 Hours of Operation. The Contractor shall routinely work during normal duty hours of the site. However, mission requirements may necessitate work outside normal hours (nights and/or weekends), especially if existing service must be interrupted. Any site work requested by the Contractor to be performed outside of normal duty hours shall be coordinated with the Base POC. 3.3 Holidays/Down Days. The Contractor shall not perform under this contract on federal holidays or site-unique down-days unless expressly authorized by the CO and coordinated with the base POC. 4.0 GOVERNMENT SUPPORTS The Contractor shall coordinate with the base POC for the Government supports. The base POC is 452 CS/SCX, commercial: +1 (555) 000-0000.

Similar Contracts

Same NAICS industry code

NAICS: 335999
New
CABLE ASSY TORPEDO, — 4920015824377 — SPRPA127QYA13
Solicitation # SPRPA127QYA13
Solicitation SPRPA127QYA13 is a request for new spares for Cable Assy Torpedo, identified by NSN 4920-01-582-4377. The Department of the Navy, through DLA Aviation at Philadelphia, seeks a total of three units, split between two line items: two units for 0001AA and one unit for 0001AB. The government intends to make a single award based on the most advantageous offer, prioritizing past performance over price. Evaluation will include SPRS risk assessments for items, pricing, and suppliers, with past performance ratings categorized from Dark Blue (top 5%) to Red (bottom 5%). Delivery is required within 90 days, FOB Destination, with inspection and acceptance occurring at the origin. The contract mandates strict adherence to military standards, including MIL-STD-2073-1 for packaging, MIL-STD-129 for marking, and ANSI/ESD S20.20-2021 for electrostatic discharge protection. Specific labeling requirements for Depot Level Repairable items and Unique Item Identification are required. Offerors must maintain active SAM registration and, if acting as a distributor, must provide an unredacted OEM Distributor Letter at the time of proposal submission to avoid being deemed non-responsive. Invoicing and payment will be processed electronically via the Wide Area WorkFlow system. Key regulatory clauses include the Buy American Act, DFARS requirements for critical safety items, and cybersecurity reporting under DFARS 252.204-7012.
Pa DLA Aviation At Philadelphia

POSTED

about 13 hours ago

DEADLINE

in 14 days
View Details

More opportunities from Department Of Defense → FA4664 452 Msg Pk

Same awarding agency

NAICS: 484121
Federal
Traffic and Fleet ManagementThe contract titled Traffic and Fleet Management is a subcontract awarded under the SDVOSB Sole Source set-aside program, designated for Service-Disabled Veteran-Owned Small Businesses. It encompasses the comprehensive management of vehicle movements, fleet accountability, and the execution of preventive maintenance for government vehicles, with additional responsibilities for contingency traffic operations to ensure operational continuity during emergencies or high-demand scenarios. The work is performance-based and focused on sustaining the readiness and reliability of the Department of Defense’s vehicle fleet under the oversight of FA4664 452 Msg Pk, with the primary place of performance located in Linda, California, 92518. The contract falls under NAICS code 484121, which classifies it within the General Freight Trucking, Long-Distance, Less-Than-Truckload category, indicating that the scope involves freight and vehicle logistics operations. The solicitation was posted on June 26, 2026, and while no solicitation number is provided, the procurement is structured as a direct award to an eligible SDVOSB based on its sole source designation. The absence of a point of contact and specific office address details suggests that administrative coordination may be managed through centralized DoD channels, with all performance activities centered at the designated location in Linda, California.
General Freight Trucking, Long-Distance, Truckload

POSTED

4 months ago

DEADLINE

N/A
View Details
NAICS: 561720
Federal
General Service Operations and Base SupportThe contract titled General Service Operations and Base Support is a sole-source subcontract awarded under the SDVOSB Sole Source category to a Service-Disabled Veteran-Owned Small Business, with the NAICS code 561720 indicating janitorial and building support services. It is intended to provide comprehensive custodial, janitorial, groundskeeping, and general logistics support to ensure the continued operation of a military installation located in Linda, California, with a ZIP code of 92518. The task encompasses routine and sustained operational maintenance functions critical to base readiness and environmental standards, including cleaning, waste management, landscape care, and logistical coordination for facility upkeep. This subcontract is part of the Department of Defense’s broader efforts to maintain base infrastructure through dedicated service providers and was posted on June 26, 2026, for award under the FA4664 452 Msg Pk agency designation. The location of performance is fixed at Linda, with no additional geographic flexibility specified. As a sole-source award, the contract bypasses competitive bidding due to the specific qualifications of the SDVOSB vendor, ensuring continuity and compliance with federal set-aside programs. The work is essential for daily operations and long-term facility sustainability, with an emphasis on reliability, adherence to defense standards, and responsive support throughout the contract period.
Janitorial Services

POSTED

4 months ago

DEADLINE

N/A
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS