J--Fire Suppression Equipment Testing !!! Intent to Sole Source !!!!

Awarded
36C25218Q9773Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Department of Veterans Affairs Great Lakes Acquisition Center plans to negotiate a sole source, firm fixed price contract with StarFire System Inc to provide fire suppression system maintenance at the Captain James A. Lovell VA Medical Center in North Chicago, Illinois. This procurement is conducted under FAR 6.302-1 due to the uniqueness of the vendor’s capabilities, and no competition will be sought unless other firms demonstrate their ability to meet the detailed requirements. The contract scope includes testing and maintenance of various fire suppression systems such as clean agent systems, dry chemical systems, preaction detection systems, and kitchen hood suppression systems across multiple buildings on the VAMC campus. Services will be performed in compliance with NFPA and JAHCO standards to ensure continued safety and regulatory compliance, involving inspections, testing of control panels, alarm devices, detection circuits, agent levels, and system shutdown functions, followed by documentation and training for VA personnel. The period of performance is scheduled from September 1 to October 1, 2018, with work to occur throughout the medical center campus. Contractor employees will adhere to strict security protocols including wearing approved identification and uniforms, parking in designated areas, and compliance with VA safety rules. Payment will be made monthly in arrears upon service completion and proper invoicing. The contractor will perform all work according to manufacturer instructions and notify the VA of any unusual conditions that might affect pricing. The procurement includes requirements for thorough reporting, refresher training, and verification that all fire suppression systems remain fully operational and compliant with safety codes. The VA reserves the right to proceed with sole source negotiations if no alternative sources demonstrate capability.

General Info

Sole source contract with StarFire for fire suppression maintenance at Lovell VA Medical Center.

Contract Value

$46,874.13

NAICS

238290 - Other Building Equipment Contractors

Place of Performance

WI, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Sources Sought

Awarded

Contract was awarded

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)
ContactsNo contacts available
OfficeMILWAUKEE, WI, 53214, USA
Office AddressMILWAUKEE, WI, 53214, USA
ContactsNo contact information available

Full Description

Show more
Page 1 of 4 The Department of Veterans Affairs Great Lakes Acquisition Center (GLAC) in North Chicago Il intends to negotiate a sole source contract with StarFire System Inc to provide Fire suppression maintenance to the Captain James A. Lovell VA Medical Center in North Chicago, IL. This contract will be for firm fixed price contract. This procurement is being conducted in accordance with FAR 6.302-1, Only One Responsible Source and no other supplies or services will satisfy the agency requirements. The contract will be firm fixed price and the NAICS code is 238290. This Notice of Intent is not a request for competitive proposals. No solicitation documents are available and telephone requests will not be honored. However, if a firm believes it can meet the requirements it must furnish information about its products, services and capabilities as well as references from other customers who are using these products and services to train staff on the Candela laser to the contracting officer NLT 11:00AM EST, 17 August 2018. Supporting evidence must be submitted in sufficient detail to demonstrate the ability to comply with the above requirements and attached Statement of Work, to include access to OEM parts for repairs. Information must be sent to: Antaeus Gayles Great Lakes Acquisition Center Southern Tier 3001 Green Bay Road Building 1, Room 326 North Chicago, IL 60064-3048 Or via fax to +1 (555) 000-0000, or via email response to contact@example.gov. Responses received will be evaluated; however a determination by the Government to not compete the proposed procurement based upon responses to this notice is solely within the discretion of the Government. If no responses are received, the GLAC will proceed with the sole source negotiation with StarFire system inc All work is expected to encounter normal conditions. Contractor to Install equipment in accordance with the manufacturers installation instructions. If anything unusual is encountered the VA will be notified and pricing will adjust accordingly. PAYMENT FOR SERVICES: Invoices will be paid in arrears on a monthly basis upon completion of the services. Each invoice must include VA purchase order number, and invoice number and the month of the service being invoiced. The invoice should be mailed to the address identified herein. SECURITY REQUIREMENTS: The Contractor s employees shall wear visible identification and company uniforms approved by the COR at all times while on the premises of the VAMC. It is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police Section or from the COTR. The VAMC will not invalidate or make reimbursement for parking violations of the Contractor under any conditions. Smoking is prohibited inside any buildings at the VAMC. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state, or municipal court. STATEMENT OF WORK FIRE SUPPRESSION SYSTEM 1. Contract Title. Fire Suppression equipment testing 2. Background. This is required testing by both NFPA and JAHCO to remain in compliance this testing must be completed and documented. 3. Scope. DESCRIPTION OF SYSTEMS TO BE SERVICED Clean Agent Fire Suppression Systems (Qty. = 4): Building 133-EF Main Computer Room, Building 133 PBX Room Building 133 Tele/Switch Room, Building 134 IRM Computer Room Dry Chemical Fire Suppression System (Qty. = 1): Dock Parking Lot HazContainer Preaction Detection System Building 133CA Pacs/Computer Room Kitchen Hood Fire Suppression Systems Buildings 201, 202, 205 & 206 (4) Fire Doors & Kitchen HoodsBuilding 133CA BD-164, Building 6 Main Kitchen, Building 133CA Canteen Kitchen, Building 133CA, Canteen Kitchen Serving Line, Building 134 C-122, Building 134 B-106, Building 134 B-207, Building 131 Room 25 Kitchen 4. Specific Tasks. WORK TO BE PERFORMED DURING NORMAL INSPECTIONS Perform control panels integrity test Test all detection devices and clean if necessary Test fusible link detection circuit (Dry Chemical System) Verify proper operation of all alarm devices Test all supervision circuits Check proper transmission of alarm and trouble signals to main fire alarm system and/or central station Check all agent release output circuits Check all solenoid release output circuits and assist with trip testing of sprinkler valve Verify proper sequence of operation is maintained Record weight and/or liquid level of agent storage containers Inspect piping for any obvious damage Verify proper orientation of agent discharge nozzles Check integrity of field wiring Verify systems are in conformance with record drawings (if available) Test equipment interlock shut-down functions (if possible) Provide refresher training course for all operating and maintenance personnel Provide test report with list of any identified problems and recommendations for correction of any problem WORK TO BE PERFORMED DURING NORMAL INSPECTION KITCHEN HOOD FIRE SUPPRESSION SYSTEMS: Verify proper operation of mechanical control heads Check integrity of pneumatic detection tubing Check integrity of fusible link cable Check integrity of fusible links and replace per National Fire Protection Agency requirements Verify proper operation of all alarm devices Check to assure nozzle caps are in place Verify agent piping is not obstructed Weigh or verify liquid level on agent storage containers Check all auxiliary equipment Verify proper sequence of operation is maintained Provide refresher training course for all operating and maintenance personnel Provide test report with list of any identified problems and recommendations for correction of any problems Place maintenance tag/certificate in the proper place Deliverables: Documentation of testing for records. 5. Performance Monitoring Contractor will work with V/A personnel to ensure all testing is completed In Accordance With required test procedures. 6. Security Requirements Contractor will be escorted during testing C&A requirements do not apply Security Accreditation package is not required 7. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI). No GFE 8. Risk Control 9. Place of Performance. Throughout campus 10. Period of Performance. 9/01/2018-10/01/2018 11. Delivery Schedule. Set start dates on or around 09-01-2018

Similar Contracts

Same NAICS industry code

NAICS: 238290
New
Centennial JCC Panic Hardware Services (Electrical Room Egress Doors)
Solicitation # Panic Hardware (Electrical Room Egress Doors)
Management & Training Corporation is soliciting bids for the installation of commercial-grade panic hardware on electrical room egress doors at the Centennial Job Corps Center in Nampa, Idaho. The project encompasses five specific locations: the Cafeteria, Men's Dorm, Women's Dorm, Recreation, and Vocational buildings. The scope of work requires the contractor to conduct site surveys, procure Grade I commercial-grade panic bars with matching exterior trim and door closers, and perform installations that ensure doors open outward under simple pressure. All work must comply with NEC 2023 Article 110.26(C)(3), NFPA 101 Life Safety Code, and the Americans with Disabilities Act. Final acceptance is contingent upon the successful completion of at least 10 consecutive cycle tests to verify fail-safe operation. This is a fee-for-service subcontracting opportunity set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications, under NAICS code 238290. Bidders must submit a lump sum bid sheet, a completed supplier packet including a W-9 and self-certification form, and three references for similar projects by December 1, 2026. The contract is subject to various Federal Acquisition Regulations, including Davis-Bacon Act prevailing wage rates for Idaho, minimum wage requirements under Executive Order 14026, and paid sick leave under Executive Order 13706. Awarded contractors must provide proof of insurance and adhere to strict government guidelines regarding information security and the protection of sensitive data.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 1 hour ago

DEADLINE

in about 1 month
View Details
NAICS: 238290
New
SLED
Pauma Security Gate
Solicitation # 2026-27-06
Solicitation 2026-27-06 for the Valley Center Pauma Unified School District involves the fabrication and installation of automated, keypad-entry hinging steel security swing gates at entry and egress driveways in Valley Center, California. The project requires two powder-coated steel double swing gates, each 18 feet wide by 5 feet tall, and explicitly prohibits the use of chain link options. Key technical components include a mounted Knox switch with Fire Department filing, two entry remotes, gate hold timers, a mounted strobe detector for emergency vehicles, and a keypad similar to the Door King 1506-086. The contract value is capped at 1,000,000 dollars, and the award will be granted to the lowest responsive and responsible bidder. Eligible bidders must hold a California contractor's license C13 or C-61/D28 and comply with prevailing wage requirements and Department of Industrial Relations registration. The project mandates a payment bond for 100 percent of the total bid price and a DVBE participation goal of at least 3 percent. Required submissions include a comprehensive bid packet featuring non-collusion affidavits, Iran Contracting Act certification, and fingerprinting certifications. Performance must be coordinated with the Director of Maintenance and Operations, with work hours restricted to 7:00 am to 5:00 pm, Monday through Friday. Additionally, contractors must adhere to strict hazardous material standards and California Air Resources Board compliance, with the district maintaining the right to terminate the agreement upon 30 calendar days written notice.
Valley Center Pauma USD

POSTED

about 10 hours ago

DEADLINE

in 5 days
View Details
NAICS: 238290
New
SLED
Districtwide Elevator And Wheelchair Lift Service, Preventive Maintenance, And Repairs Maintenance Services
Solicitation # 27.004
The Hayward Unified School District is soliciting bids under solicitation number 27.004 for districtwide elevator and wheelchair lift service, preventive maintenance, and repairs. The selected contractor will be responsible for the systematic examination, maintenance, and repair of all owned or leased systems, including hydraulic, electrical, and mechanical components, to ensure they remain in safe and usable condition. This contract requires the provider to hold an active C-11 Elevator Contractor license from the State of California and comply with all local and state codes, including Title 24 of the California Code of Regulations. The award will be granted to the lowest responsive and responsible bidder based on the rates provided in the bid form. Performance of regular services typically occurs Monday through Friday during standard business hours, while emergency repairs must be available 24 hours a day, seven days a week. The contractor must provide a bid bond of at least 10 percent of the bid amount and subsequently provide payment and performance bonds upon award. Invoicing is conducted monthly, with a requirement that authorized materials be invoiced at no more than 15 percent above the vendor's cost. Key compliance requirements include paying prevailing wages per the California Labor Code, submitting to fingerprinting and felony conviction certifications, and maintaining a minimum one-year warranty on work. All contracts are governed by the laws of the State of California.
Hayward Unified School District

POSTED

about 11 hours ago

DEADLINE

in 20 days
View Details

More opportunities from Department Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)

Same awarding agency

NAICS: 333415
New
Federal
36C25227Q0048 - COOLERS AND FREEZER
Solicitation # 36C25227Q00480001
Solicitation 36C25227Q0048 is a combined supply contract issued by the Department of Veterans Affairs, Great Lakes Acquisition Center, for the provision and on-grade installation of an indoor walk-in cooler and freezer system at the Captain James A. Lovell Federal Health Care Center in North Chicago, Illinois. The required unit measures 44 feet 6 3/4 inches by 31 feet 7 inches by 8 feet 6 inches, featuring specific panel thicknesses of 5 1/2 inches for freezer walls and ceilings and 4 inches for cooler walls and ceilings. The system must be constructed with 2021 IEC C403.11 compliant wood frame panels and include various accessories such as vapor proof lights, heated vents, dial flush thermometers, and an exterior ramp. This procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). Eligible offerors must be listed in the SBA certification database and comply with strict limitations on subcontracting, ensuring that no more than 50 percent of the contract value is paid to firms that are not certified SDVOSBs or VOSBs. The solicitation has undergone three modifications to add technical drawings, incorporate site visit and Q&A details, and extend the final response deadline to November 6, 2026, at 10:00 a.m. CT. Offerors are required to certify their status as either a domestic manufacturer or a nonmanufacturer supplying a domestic small business product to be considered for award.
Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

POSTED

about 11 hours ago

DEADLINE

in 9 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS