Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity was posted on June 20, 2019. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J--Pneumatic Controls Service

Awarded
36C24119Q0268Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management and Training Corporation is soliciting lump sum fee proposals for the clutch replacement of a Kubota M8200 tractor with front wheel assist, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires a qualified contractor to provide all transportation, labor, materials, and equipment to diagnose and repair the clutch assembly and power take-off system. Key technical requirements include replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as needed. The contractor must perform all work according to manufacturer specifications and provide a final summary of diagnostic findings, an itemized list of replaced parts, and warranty documentation upon completion. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Bids must be submitted via email to Angie Mahoney by 3:00 PM CST on November 3, 2026, and must include a bid sheet, proof of insurance, a completed supplier packet with a W-9, and applicable SBA certification letters. Award decisions will be based on best value, with a focus on administrative compliance and technical qualifications. The contract is subject to various Federal Acquisition Regulations, including standards for combating trafficking in persons, Buy American restrictions, and Service Contract Labor Standards per Wage Determination 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
ANNUAL ROTATING EQUIPMENT INSPECTION, TESTING, REPAIR, RECONDITIONING AND STORAGE SERVICES
Solicitation # 2026-RFP-130
Solicitation 2026-RFP-130, issued by the City of Lakeland, seeks qualified contractors to provide annual inspection, testing, repair, reconditioning, and storage services for critical rotating equipment at the McIntosh and Larsen Power Plants. The scope of work covers a wide range of industrial machinery, including low- and medium-voltage AC and DC electric motors, as well as circulating water and condensate pumps. Required services include clean inspect test (CIT) procedures, troubleshooting, motor rewinding, machining, welding, and dynamic field balancing. The contractor is also responsible for the pickup, transportation, and secure indoor storage of equipment, ensuring strict preservation measures such as periodic shaft rotation and moisture control to prevent corrosion and damage. The selection process is based on a points-based criteria to identify the vendor most responsive to the city's needs. Proposers must submit their responses via the OpenGov portal by October 30, 2026, and provide essential documentation including a signed W-9, Sunbiz registration, a notarized indemnification agreement, and a human trafficking affidavit. Contractors must adhere to strict safety standards, including OSHA compliance and specific certification for crane operations and critical lifts. Furthermore, vendors are required to maintain insurance policies with AM Best ratings of no less than A and must undergo a safety audit covering EMR and employee training records to ensure compliance with city risk management standards.
LE - Production - MPP

POSTED

about 7 hours ago

DEADLINE

in 8 days

AI Contract Overview

Show more

The Department of Veterans Affairs intends to award a sole source contract to Quincy Compressor LLC for preventive maintenance and repair services for medical air compressors and vacuum pumps at the West Haven VA Medical Center in Connecticut. The scope of work includes providing all labor, materials, tools, and supervision to service medical air, medical vacuum, and compressed air systems for pneumatic controls, including associated dryers, sensors, and monitors. The government is pursuing a sole source award because Quincy Compressor currently services existing warranties that would be voided if another vendor were used. The contract structure consists of a one-year base period with four optional one-year renewals. Key requirements include monthly walk-through inspections, specific maintenance schedules for reciprocating, rotary screw, and vacuum equipment, and a 24/7 emergency response time of within two hours. The contractor must also provide written reports after each service call and ensure technicians adhere to hospital infection control measures. This action is categorized under NAICS code 811310 with a small business size standard of 7.5 million dollars.

General Info

Agency

N/A

Contract Value

$347,448.08

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Department of Veterans Affairs;Connecticut HCS;West Haven Campus;950 Campbell Avenue;West Haven, CT 06516 USA, CT, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Presolicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Pursuant to Federal Acquisition Regulation (FAR) 8.405-6(a)(1)(i)(B), The Connecticut Health Care System for the Department of Veterans Affairs intends to issue a sole source contract award to Quincy Compressor LLC 14500 Lochridge blvd Ste A Covington, GA 30014-4941. The contract will include Preventive Maintenance & Repair Service for Medical Air Compressors and Vacuum Pumps for Connecticut HCS Facilities and Maintenance 950 Campbell Avenue West Haven, CT 06516. The applicable NAICS code will be 811310 with an applicable small business size standard of $7.5 Million. The performance period is for a 1-year period with an option of four years and will provide all equipment, labor, materials; to include tools, parts, transportation, supervision, permits and disposal necessary to service all medical air, medical vacuum, and compressed air for pneumatic controls with all associated dryers, sensors and monitors at the West Haven VA Medical Center, 950 Campbell Ave., West Haven, CT 06516. Contractor to be responsible for obtaining mfg. Spec s as needed with copies for engineering dept. The Connecticut HCS has warranties currently being serviced by Quincy Compressor and use of another vendor would void these warranties. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. It is a market research tool being used to determine the availability of other qualified sources that can meet the requirements identified above and inherent with the referenced product. The Government is not obligated to and will not pay for any information received from potential sources as a result of this notice of intent. All responses received within 15 days of the posting of this notice will be considered by the Government. A determination by the Government to require services for The Connecticut HCS, acquisition based on this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purposes of determining whether to allow alternate service providers. Submit any responses within 4 days of the posting of the notice of intent via email to: contact@example.gov. THIS NOTICE OF INTENT IS NOT A REQUEST FOR PROPOSALS OR QUOTATIONS. No solicitation package will be issued. A determination by the Government not to compete this proposed action based upon responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether conducting a competitive procurement is in the best interest of the Government. All responses received by 13:00 EST on 26 June 2019 will be considered by the Government. This notice is not a request for competitive proposals/quotes. All information submitted should support the offeror's capability to provide the items required and shall be furnished at no cost or obligation to the Government. Responses must be in writing and must provide clear and concise documentation indicating an offeror's capability to provide these services. Verbal responses are not acceptable and will not be considered. Responses and questions shall be submitted via email to: contact@example.gov. The Government will issue a Limited Sources Justification (LSJ) to support the need for a sole source award. The LSJ will post to the GPE at http://www.fedbizopps.gov, within fourteen (14) days after award of the task order. Statement of Work Preventive Maintenance & Repair Service for Medical Air Compressors and Vacuum Pumps for VA Connecticut Healthcare System West Haven, CT Contractor shall provide all equipment, labor, materials; to include tools, parts, transportation, supervision, permits and disposal necessary to service all medical air, medical vacuum, and compressed air for pneumatic controls with all associated dryers, sensors and monitors at the West Haven VA Medical Center, 950 Campbell Ave., West Haven, CT 06516. Contractor to be responsible for obtaining mfg. Spec s as needed with copies for engineering dept. Preventive Maintenance The contractor shall provide a monthly walk-through to inspect all equipment listed on bid spec on the equipment listed below: QTY MFG Description / Medical Air / Medical Vacuum Bldg/Location 1 Beacon Medical Vacuum / Model # OV8A-ITBS-TC001 SER# 65503 1-SG182 1 Quincy Medical Vacuum / Model # QSVB10 SER# UNO64010 1- 5th Floor 1 Quincy Medical Vacuum / Model# QSVB10 SER# UNO640009 1-5th Floor 1 Busch Medical Vacuum / Model# MM1104AB SER# 050044109 2-7-100 1 Airtech Dental Vacuum / Model# 1-DV-7620-5-TANV #959 2-G-139 1 Chemtron Medical Vacuum / Model# LPHR 50518 BN11 7020 2-G-139 SER# 348618 SER# 3448619 1 Airtech Research Vacuum / Model# 2BL2061-1AH50-4AS200 4-Basement 1 Power-X Medical Air / Model# SPL3471698 Cat Number M3218T 1-5th Floor 1 Power-x Medical Air / Model# SPL3485304 Cat Number MS218T 1-SG-182 1 Power-X Medical Air / Model# SET150740 1-SG-177 1 Power-X Dental Air / Model# SET150740E 2-G-139 1 Power-X Medical Air / Model# SPL2923735 2-G-139 1 Speed Air Pneumatic Air / Model# 4YN50A SER# 2008-00040 2-2-113 (Wood Shop) 1 Quincy Pneumatic Air / Model# PLT-5 SER# 200301120-01956 2-2-113 1 Quincy Pneumatic Air / Model# PLT-5 SER# 6144416 2-2-113 1 Quincy Pneumatic Air / Model# 390 SER# 339931 2-G-139 1 Quincy Pneumatic Air / Model# 390L103 SER# 400451RL 2-G-139 1 Quincy Pneumatic Air / Model# 310 SER# 20041018-0013 2-G-139 1 Quincy Pneumatic Air / Model# QT5QCB SER# 20060112 4-Basement 1 Quincy Pneumatic Air / Model# QT5QCB SER# 200602240057 Bldg 34 1 Quincy Pneumatic Air / Model# 310 SER# 20041018-0011 1-SG-101 1 Hitachi Pneumatic Air / Model# 5-5OU-8.5CH SER# OC858837 1-SG-170 1 Quincy Pneumatic Air / Model# QSB15ANA11SQ SER# 97726H 1-SG-182 1 Kobelco Pneumatic Air / Model# KNWA00-A/L SER# 01A0106 1-SG-182 1 Quincy Pneumatic Air / Model# QSB15ANA11SQ SER# 97725H 1-10th Floor 1 Quincy Pneumatic Air / Model# 390101 SER# 339932 1-10th Floor 1 Johnson Control Pneumatic Air / Model# AD030 SER# 050692L-209094 1-5th Floor 1 Ingersol Pneumatic Air / Model# BS15 SER# 100309 Boiler Plant QTY MFG Description / Pneumatic Control Air/Fire Suppression Bldg/Location 1 Quincy Pneumatic Air / Model# 390 QRV-ROCO Boiler Plant 1 Quincy Pneumatic Air / Model# QT5QCB SER# 20060224-0055 Bldg 21 1 Jenny Fire Suppression / Model FIS-BS SER# G072JJ4020 Boiler Plant 1 Jenny Fire Suppression / Model# K SER# F122211025 3-Basement 1 Magnetech Fire Suppression / Model 8-164550-23 7-Basement Reciprocating compressors will be serviced as follows: Air filter element replacement Change oil Change oil filter Replace Belts one time per year Replace unloader diaphragms one time per year Inspect dryer- air clean exterior of condenser with compressed air Check temps/ pressures Check drain trap operations Powerex Systems will be serviced as follows: Change air filters one time per year Change floats in water separators Change line filter element and floats Change belts Change dryer exhaust filters two times per year Change HC elements once per four years The Rotary screw compressors and vacuum pumps will be serviced as follows: Oil sample taken Change oil filters Replace Separators (Every 4000 hours of operation) Check belts (Change belts every 4000 hours of operation) Change air filter elements Check safeties Clean Exterior of coolers with compressed air Clean entire unit Airtec Vacuum Pumps will be serviced as follows: Change water filters two times per year Change air filter elements two times per year Dryers- install overhaul kits and desiccant (every 2 years) Three emergency (after hours) callouts for labor only Six dew point probes to be on a two-year calibration schedule Parts Contractor shall include a list of all parts covered by Preventive Maintenance with the cost mark up. Contractor shall provide the cost mark up for parts not included in the Preventive Maintenance. Additional Equipment Additional equipment may be added or existing equipment removed from the list when necessary to meet the changing needs of the facility which may be required throughout the life of the contract and shall be considered within the scope. Written Reports Written reports for the work completed and recommendations on repairs shall be required with a cost quote included after each PM and/or service call. Emergency & Repair Service Work The contractor will be required to provide 24/7 response to emergency air compressor and vacuum pump system problems. Response time will be with-in 2 hour time frame. The contractor will provide a straight time hurly rate and an overtime hourly rate for emergency call-ins and routine repair service. In the event of a major breakdown a suitable rental must be available within 24 hours. Performance Work Statement Tasks The contractor shall be available to perform the semi-annual preventive maintenance on a schedule that is satisfactory to the hospital. The contractor shall work continuously on preventive maintenance once the work has started until all the units specified in the contract are completed. The contractor shall provide legible and complete reports on all equipment that received preventive maintenance including the repairs required and a cost proposal to perform the repair. The contractor shall respond to all emergency repair call ins within the 2 hour time frame specified. The contractor shall provide highly qualified technicians with adequate training to resolve all repair issues encountered. Infectious Control The Contractor shall conform to the infection control measures as specified in the attached Construction Specification for Infection Control. Preventive Maintenance Service will normally but not always is performed in a separate work area not subject to all the infection control procedures. Repairs and emergency repairs may be conducted in patient rooms and other hospital areas that are subject to infection control encountered. Work Hours and Project Sequence Routine PM and repair work can start as early as 7:00am and work past 4:30pm week days. Weekend work needs to be approved by the Mechanical Maintenance Supervisor. Emergency service work will occur as conditions dictate. Duration This service contract will be for a Base Year and four (4) one (1) year options renewable at the discretion of the VA. COR: Euel Sims, Mechanical Maintenance Supervisor

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS