J012--Kitchen Exhaust Cleaning, Kitchen Fire Suppression System Service, and Portable Fire Extinguisher Service

Open
36C25627Q0131Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

4300 West 7th Street Little Rock. AR 72205, North Little Rock, MS, 72114

Set-Aside

NONE

Documents

2
DOCX
PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)
Contacts1 person available
OfficeRIDGELAND, MS, 39157, USA
Office AddressRIDGELAND, MS, 39157, USA
Contacts
Anthony MarionContracting Officer

Full Description

Show more
1. Title: Kitchen Exhaust Cleaning, Kitchen Fire Suppression System Service, and Portable Fire Extinguisher Service
2. Background: Per NFPA 96, the new Food Services Center (Bldg. 211), and JLM dietetics are required to have their kitchen hoods cleaned semiannually due to limited grease use and/or limited meal service. The hoods for JLM, B170, and 202 require quarterly cleaning due to the heavy grease operations. During regular cleaning, the hood system must be inspected, tested and maintained. Per NFPA and regulatory requirements, kitchen fire suppression systems shall be inspected and serviced at a minimum of every 6 months to ensure proper operation and life safety compliance. Given that the kitchen fire suppression systems will be inspected, government is including the inspection, testing and maintenance of the portable fire extinguisher. Per NFPA and regulatory requirements, portable fire extinguishers shall be inspected, serviced, and hydrotested to ensure proper operation. 3. Purpose: The Network Contracting Office (NCO) 16, located at Galleria Financial Center, 5075 Westheimer Rd, Ste 750, Houston, TX 77030, hereby issues the following Sources Sought to Request Information (RFI) with the intent of determining the contractor interest, capabilities, qualifications of potential businesses and estimated industry pricing information for market research and estimated budgetary purpose for Kitchen Exhaust Cleaning, Kitchen Fire Suppression System Service, and Portable Fire Extinguisher Service
4. Requirement summary: The Government presently considers fire-protection equipment inspection, testing, preventive maintenance, recharge, hydrostatic testing, repair, authorized replacement, and restoration to be the predominant purpose of the integrated requirement. Accordingly, North American Industry Classification System code 811310 is proposed. 
The anticipated requirement combines recurring commercial services at the John L. McClellan Memorial Veterans Hospital in Little Rock and the Eugene J. Towbin Healthcare Center in North Little Rock. The draft scope includes: 
Quarterly and semiannual cleaning of identified commercial kitchen hoods, plenums, ducts, fans, dampers, and related exhaust-system components.  Semiannual inspection, testing, maintenance, tagging, and documentation for 10 wet-chemical kitchen fire suppression systems.  Inspection, maintenance, recharge, hydrostatic testing, repair, authorized replacement, pickup, return, tagging, and asset-level reporting for approximately 948 portable fire extinguishers across listed classes and locations.  Qualified personnel, manufacturer authorization when required, calibrated test equipment, safety controls, chemical and waste management, impairment coordination, incident reporting support, and digital service records.  A potential base period with four one-year option periods. The final contract structure and quantities have not been determined. 
Respondents should address the ability to perform all three principal service areas as the prime contractor and identify any anticipated subcontracting or teaming arrangement.
5. Requested capability information: Interested parties should submit a concise capability statement, preferably no more than 10 pages excluding cover page and supporting certifications. Clearly identify proprietary information. Address each item below in the order listed. 
Legal business name, physical address, website, and primary point of contact, including name, title, telephone number, and email address.  Unique Entity Identifier and Commercial and Government Entity code.  Business size under proposed North American Industry Classification System code 811310 and any recommended alternative code.  Socioeconomic status, including small business, veteran-owned small business, service-disabled veteran-owned small business, women-owned small business, economically disadvantaged women-owned small business, Historically Underutilized Business Zone small business, 8(a) participant, or small disadvantaged business. Identify current Small Business Administration VetCert status when claiming veteran-owned or service-disabled veteran-owned status.  Whether the respondent intends to perform as the prime contractor and the approximate percentage of work the respondent expects to perform with its own employees.  Capability to provide all required service areas at both campuses, including after-hours kitchen exhaust cleaning and normal-business-hours fire protection services.  Current qualifications and certifications relevant to National Fire Protection Association Standards 10, 17A, and 96; Underwriters Laboratories 300-listed systems; Ansul and PyroChem systems; kitchen exhaust cleaning; extinguisher maintenance; and hydrostatic testing. Identify whether credentials are held by the respondent or a proposed subcontractor.  At least two recent and relevant contracts or projects completed within the past five years. Include customer, contract or project identifier if releasable, period of performance, dollar magnitude or range, scope, locations, and customer point of contact if authorized.  Available staffing, mobilization timeframe, service radius, emergency or impairment response capability, and ability to maintain recurring schedules at both campuses.  Quality-control approach, asset tracking, service-report format, deficiency management, chain-of-custody controls, and ability to provide searchable Microsoft Excel or Portable Document Format reports.  Any contract vehicle available to the Government, including Federal Supply Schedule contract information, if applicable. 
6. Licenses, certifications, and technical qualifications: Respondents shall identify the licenses, certifications, manufacturer authorizations, and technical qualifications currently available to perform the draft requirement. A credential matrix is acceptable at the Sources Sought stage. Do not submit Social Security numbers, dates of birth, home addresses, or other unnecessary personal information.
Current Arkansas Fire Protection Licensing Board company Certificate of Registration for portable fire-extinguisher systems and fixed fire-suppression systems.
Current individual Arkansas licenses for proposed or available technicians covering portable fire extinguishers, fixed wet-chemical fire-suppression systems, and hydrostatic testing, as applicable to assigned work.
Current Ansul and Pyro-Chem manufacturer-authorized distributor, service-provider, or technician documentation applicable to the installed system models. Identify any other manufacturer authorization available.
International Kitchen Exhaust Cleaning Association Certified Exhaust Cleaning Specialist, Certified Exhaust Cleaning Technician, or an equivalent nationally recognized commercial kitchen exhaust-cleaning credential for the proposed crew leader or onsite supervisor. A Professional Exhaust Cleaning Technician designation should be identified as a designation rather than represented as a full certification.
Current Pipeline and Hazardous Materials Safety Administration Requalifier Identification Number approval for any facility that will inspect, test, mark, or requalify regulated cylinders. If this work will be subcontracted, identify the proposed testing facility and provide its approval information.
Current Arkansas hydrostatic-testing license or certificate applicable to the cylinder classes and testing methods proposed.
Current calibration certificates for pressure gauges, scales, hydrostatic-test equipment, electrical test instruments, and other measurement equipment whose accuracy affects inspection or acceptance.
Relevant safety-training records, including lockout/tagout, hazard communication, personal protective equipment, fall protection or rooftop work, ladder or lift operation, respiratory protection when applicable, and spill response.
Current certificate of general liability insurance and identification of workers compensation and automobile liability coverage available for performance, pickup, and delivery activities.
Active System for Award Management registration, Unique Entity Identifier, Commercial and Government Entity code, business-size representation under North American Industry Classification System code 811310, and current Small Business Administration VetCert status when claiming veteran-owned or service-disabled veteran-owned small business status.
Credential matrix. For each credential, identify the issuing organization; company or individual holder; employer; credential or license number; covered equipment or service; issue date; expiration date; and whether the capability is held by the respondent or a proposed subcontractor.
At the Sources Sought stage, respondents are not required to provide a final roster for every technician who may perform under a future contract. However, respondents should provide sufficient evidence for the Government to assess whether the required licensed and certified capability is available. Any future solicitation may require named personnel and complete credential copies with the quotation or proposal, before award, or before the individual begins regulated work.
7. Place of Performance:
Location #1: John L. McClellan (JLM) Memorial Veterans Hospital Central Arkansas Veterans Healthcare System 4300 West 7th Street Little Rock. AR 72205
Location #2: Eugene J. Towbin Healthcare Center Central Arkansas Veterans Healthcare System 2200 Fort Roots Drive North Little Rock, AR 72114
8. Responses Requested: The NCO 16 requires all the following information and questions answered above in this notice.
9. Opportunity: The NCO 16, is seeking information from potential contractors on their ability to provide this service. THIS IS A SOURCES SOUGHT FOR REQUEST INFORMATION (RFI) ONLY. Small Business Concerns are encouraged to provide responses to this Sources Sought in order to assist the NCO 16 in determining potential levels of competition available in the industry. Contractor shall possess the capability to provide all requirements and objectives.
10. Instructions and Response Guidelines: Sources Sought responses are due by November 20, 2026 at 10:00 am (CST) via email to anthony.marion2.gov.
All Questions shall be submitted by November 13, 2026 at 10:00 pm (CST) via email to anthony.marion2.gov.
Telephone requests or inquires will not be accepted.
Public Information will not be provided and shall be utilized to the full extent possible.
This a New Requirement.
The subject line shall read: 36C25627Q0131 -RFI-Sources Sought- Kitchen Exhaust Cleaning, Kitchen Fire Suppression System Service, and Portable Fire Extinguisher Service. NO SOLICITATION EXISTS AT THIS TIME.
Please provide the information you deem relevant in order to respond to the specific inquiries of the Sources Sought. Information provided will be used solely by NCO 16 as "market research" and will not be released outside of the NCO 16 Purchasing and Contract Team.
This Sources Sought notice does not constitute a Request for Proposal (RFP), Invitation for Bid (IFB), or Request for Quotation (RFQ), and it is not to be construed as a commitment by the Government to enter into a contract, nor will the Government pay for the information submitted in response to this request. All information contained in this Sources Sought is preliminary as well as subject to modification and is in no way binding on the Government.
In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract. If a solicitation is released, it will be synopsized on Contracting Opportunities (https://beta.sam.gov/) website or GSA. It is the responsibility of the interested parties to monitor these sites for additional information pertaining to this Sources Sought, or future RFP/RFQ.
11. Contact Information: Contract Specialist, Anthony Marion Email address: contact@example.gov Your responses to this notice are appreciated.
THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES/PROPOSALS; however, any firm that believes it can meet the requirements may provide answers, responses and give written notification prior to the response due date and time. Supporting evidence and responses must be furnished in enough detail to demonstrate the ability to perform the requirement.

Similar Contracts

Same NAICS industry code

NAICS: 811310
New
Federal
Hydrostatic Testing
Solicitation # M6740027Q0001
The Department of Defense, through the Commanding Officer at Marine Corps Air Station Iwakuni, is soliciting a firm fixed price contract for the hydrostatic testing of 81 Amerex B674 Wheeled Halotron I Fire Extinguishers. Performance is scheduled to take place between January 15, 2027, and March 15, 2027, either at Marine Corps Air Station Iwakuni or another mutually agreed upon location. All testing and visual examinations must strictly adhere to NFPA 10, CGA C-1, CGA C-6, and DOT Title 49 CFR Part 180 standards. The contractor is responsible for ensuring structural integrity through 100 percent inspection, maintaining specific expansion limits for low pressure cylinders, and providing detailed marking and labeling including the test date, pressure used, and the identity of the testing agency and individual. Interested offerors must submit their quotations by November 30, 2026, at 0800 JST, with all inquiries directed to the primary point of contact by November 16. Submissions must include a quotation with full pricing, a technical approach not exceeding three pages that details logistical plans and testing methodology, and a one page summary of relevant past performance from the last five years. Award will be granted to the responsible offeror deemed most advantageous to the government based on technical acceptability and price reasonableness. Administrative requirements include active SAM registration and electronic invoicing via the Wide Area WorkFlow system.
Commanding Officer

POSTED

about 14 hours ago

DEADLINE

in 24 days
View Details
NAICS: 811310
New
Federal
PES E-Unit Footer Repair
Solicitation # FA9101_PESEUNITREPAIR
The Department of Defense, through the Air Force Test Center Installation Contracting Division, is issuing a Sources Sought Notice to identify small and large businesses capable of performing emergency structural thread repair and precision mechanical alignment for an Allis Chalmers 1409 axial compressor. Located in the Propulsion Wind Tunnel Area at the Arnold Engineering Development Complex in Tennessee, the project requires lifting an 80,000 lbf compressor unit to repair stripped female attachment threading on the north-west footer and 12 bolt holes on three other footers. The scope includes replacing 16 bolts with hardware that meets or exceeds original 2-1/2”-8 specifications, reconnecting the compressor to the motor and aft compressor using provided couplers and shim packs, and performing a cold alignment of the complete drive system. The contractor is responsible for providing the necessary crane for lifting the compressor and couplers, and must submit a detailed lift plan five working days prior to execution. All work must be completed within 15 workdays, with a final deadline of December 15, 2026. Interested respondents must provide their company information, SAM Unique Entity Identifier, and a brief description of their technical approach to meet the requirements within the specified timeframe. Responses are due by November 10, 2026, to the designated points of contact. This notice is for informational purposes to determine market capability and does not constitute a formal solicitation or request for quote.
FA9101 Aedc Pkp Procrmnt Branch

POSTED

about 14 hours ago

DEADLINE

in 5 days
View Details
NAICS: 811310
New
Federal
USS AMERICA (LHA-6) MATERIAL HANDLING EQUIPMENT (MHE) REFURBISHMENT
Solicitation # N0024427R0005
The Navsup Fleet Logistics Center San Diego is seeking a Service-Disabled Veteran-Owned Small Business (SDVOSB) under NAICS code 811310 to perform the overhaul and refurbishment of twenty-three Material Handling Equipment (MHE) assets for the USS AMERICA (LHA-6) Aircraft Intermediate Maintenance Department. The objective is to restore these assets to full operational capability and OEM specifications or better to support aviation logistics and flight operations. The project involves off-ship refurbishment at a contractor facility within San Diego County, California, with a performance period of 180 business days from the first asset induction, excluding time for parts procurement. Refurbished assets are expected to be delivered to government storage by approximately March 2027. The scope of work includes induction inspections, corrective maintenance, corrosion treatment per TM 4795-12/1, and repainting using lead and chromate-free yellow paint per SAE AMS-STD-595. Critical requirements include operational verification of mechanical, hydraulic, braking, and steering systems, as well as Weight Handling Equipment (WHE) certification in accordance with NAVFAC P-307 and NAVSEA SW023-AH-WHM-010. Powder coating and battery replacements for 4,500 lb electric assets are excluded from the base scope. This is anticipated to be a Firm-Fixed-Price contract with payments made on a delivery basis via Wide Area WorkFlow (WAWF), governed by FAR 52.232-25. Interested respondents must submit a capability statement by November 16, 2026.
Navsup Flt Logistics Ctr San Diego

POSTED

about 14 hours ago

DEADLINE

in 11 days
View Details

More opportunities from Department Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)

Same awarding agency

NAICS: 339113
New
Federal
6515--Shukla Universal Large Screw Extraction Systems Brand Name or Equal
Solicitation # 36C25627Q0122
The Department of Veterans Affairs, Network Contracting Office 16, is conducting market research via a Sources Sought Notice to identify qualified sources for orthopedic extraction and removal systems for the Michael E. DeBakey VA Medical Center in Houston, Texas. The requirement focuses on replacing existing instrumentation for trauma, total joint, spine, shoulder, and related surgical procedures, specifically seeking Shukla Universal Screw Extraction Systems or equals. The requested items include various extraction and removal systems for trauma, small bone screws, broken and stripped screws, knee, hip stem, spine (cervical, thoracic, and lumbar), and shoulder, as well as osteotome blade systems. All equipment must be new, surgical-grade, FDA compliant, and compatible with existing facility workflows and sterilization processes. The anticipated contract will be a single award, firm fixed price agreement under NAICS code 339113. Interested respondents must provide company identifiers, business size status, and evidence of availability via government-wide contract vehicles. To be considered responsive, vendors must submit an Authorized Distribution Letter on OEM letterhead to prove they are not providing grey market items, confirm their ability to provide training, and provide estimated market research pricing. Responses are due by November 12, 2026, to the contracting officer, Robert Arabie. This notice is for planning purposes only and does not constitute a formal solicitation.
Surgical Appliance and Supplies Manufacturing

POSTED

about 14 hours ago

DEADLINE

in 7 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS