Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on December 10, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J059--Inspection and Maintenance for Caterpillar 3512 Generators and Caterpillar Paralleling Switchgear

Closed
36C26025Q0113Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 335312
New
DIBBS
MOTOR-TACHOMETER GENER
Solicitation # SPE7M1-26-T-390M
Solicitation SPE7M1-26-T-390M, issued by DLA Land and Maritime, is a request for quotations for 27 units of a Motor-Tachometer Generator, identified by NSN 6105014468553. This is a critical application item that must be manufactured in accordance with specific limited rights data and source controlled drawings, specifically referencing Electromech Technologies LLC part number U-222303. The procurement is categorized under NAICS code 335312, with delivery required within 388 days after order. The items are to be delivered FOB Origin to the DLA Distribution Depot at Hill AFB, Utah, with both inspection and acceptance occurring at the destination per FAR 52.246-2. The contract mandates strict adherence to DLA packaging requirements, specifically RP001 and ASTM D3951, with all marking and labeling following MIL-STD-129. Technical and quality requirements are governed by the DLA Master List, and the contractor must comply with configuration change management and the removal of government identification from non-accepted supplies. Administrative requirements include the use of the Wide Area WorkFlow system for invoicing and payment. Offerors must submit quotes via the DIBBS portal and comply with various DFARS and FAR clauses, including those regarding cybersecurity, domestic sourcing under the Buy American Act and Berry Amendment, and the prohibition of covered telecommunications equipment.
MARITIME SUPPLY CHAIN

POSTED

about 7 hours ago

DEADLINE

in 5 days

General Info

NAICS

335312 - Motor and Generator Manufacturing

Place of Performance

WA

Set-Aside

NONE

Documents

1

Sources Sought Notice 36C26025Q0113 for Caterpillar Generator Maintenance

DOCX, High priority: read this firstsources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Notice updated

The notice title changed. The notice description changed. The point of contact changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Contacts1 person available
OfficeVANCOUVER, WA, 98661, USA
Office AddressVANCOUVER, WA, 98661, USA
Contacts
Helen WoodsContracting Officer

Full Description

Show more
Sources Sought Notice Page 4 of 4 This is an unrestricted full and open sources sought notice for a services requirement to assist the Government in determining the appropriate acquisition strategy by requesting industry input. To assist the Government with this determination, if you are interested in the requirement described below, submit the following to contact@example.gov by 1700 Thursday 12 December 2024: Your company name and SAM UEI number. A brief statement of your company s capability specific to this requirement for a maximum of two (2) pages. Form responses concerning capability will not be considered. If your company is a SDVOSB/VOSB, your capability statement should address VAAR 852.219-75 (JAN 2023) (DEVIATION) s limitations on subcontracting and how your company can provide the requirement within the 50% restriction on subcontracting. If you are a certified service provider for Caterpillar, documentation to substantiate this status may be included as additional pages. (Optional) Any in process applications with SBA for your business size status or similar? Requirement Synopsis: The VA facility located in White City, OR, has a requirement for the annual inspection and maintenance for two (2) 3512 Caterpillar generators as well as the once every five years inspection and maintenance for their Caterpillar paralleling switchgear. For the 3512 s annual inspection and maintenance, the facility is looking for either full or green service. Green service must include a full spectral analysis yearly with results supplied to the facility to determine if the oil needs changed out of the three-year green cycle for the crankcase oil. The requirement will also include triannual replacement of engine batteries, as well as Cooling System services, such as coolant replacement. The annual full spectral analysis will also be used to determine if the coolant needs replaced out of the three-year cycle. More details including final scope documents will be provided if a solicitation is issued. The anticipated NAICS code is 335312 and the anticipated Product Service Code (PSC) is J059. Companies providing responses must be authorized to work on the referenced Caterpillar equipment and provide substantiating documentation. If no qualified and capable companies provide response by 1700 Pacific on 12 December 2024, VA may sole source this requirement to a Caterpillar service center. The Government thanks industry for their assistance with determining the appropriate acquisition strategy for this requirement. Please note, telephonic requests will not be honored at this time. Please respond to this posting by email only to the point of contact provided above. Any out of office responses are not applicable to this posting unless specifically identified as such.

More opportunities from Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)

Same awarding agency

NAICS: 238220
New
Federal
J041--White City B249 SE HVAC Repair
Solicitation # 36C26027Q0102
Solicitation 36C26027Q0102 is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) issued by the Department of Veterans Affairs. The contract requires the repair of a Mitsubishi R-410A comfort-cooling system (Serial 07W0090) located on the southeast side of Building B249 at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The scope of work includes leak detection, brazing repairs with nitrogen purge, refrigerant recovery, evacuation to less than 500 microns, and recharging the system to nameplate requirements. The contractor must provide a detailed service report documenting the root cause, repair actions, and compliance with EPA Section 608 and VHA ICRA/PCRA controls for occupied healthcare facilities. The period of performance is 30 calendar days from the Notice to Proceed. Award will be granted to the responsible offeror whose proposal is most advantageous to the government, considering price and other specified factors. Key regulatory requirements include adherence to OSHA 29 CFR 1910.147 for lockout/tagout and 29 CFR 1910.333 for electrical safety. Payments will be processed via Electronic Funds Transfer, and invoices must be submitted electronically through the Tungsten Network. Offerors must provide their Unique Entity Identifier and maintain firm pricing for 60 calendar days from the response deadline of November 10, 2026.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in 12 days
View Details
NAICS: 334513
New
Federal
Boiler Plant O2 Sensor Replacement
Solicitation # 36C26027Q0101
The Department of Veterans Affairs, through the Network Contract Office 20, is conducting market research via a Sources Sought Notice for a firm-fixed price service contract to perform inspection, testing, maintenance, and repair of three model 6888 Rosemount flue gas analyzers. The work will be performed at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The primary scope involves replacing internal O2 analyzer components using original equipment manufacturer parts, specifically 18 inch standard cells, 18 inch heater strut assemblies, Hastelloy with Vee Deflectors for service up to 1300 degrees Fahrenheit, and new flange gaskets. The period of performance is six months, with on-site work required during core hours of 7:00 AM to 4:00 PM, Monday through Friday. This opportunity is designated as a total Small Business Set Aside under NAICS code 334513, with a size standard of no more than 750 employees. Qualified sources, including SDVOSB and VOSB entities, must provide company details, SAM.gov UEI numbers, and proof of manufacturer authorization if they are not the OEM. Contractors must employ qualified personnel, maintain general third-party liability insurance per FAR 52.228-5, and adhere to NEC, OSHA, and JCAHO standards. Deliverables include written daily reports to the Deputy Chief Facilities Management and testing documentation provided to the Contracting Officer's Representative. Interested parties are requested to provide a courtesy quote and capability statement to assist the government in evaluating price reasonableness and market availability.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

2 days ago

DEADLINE

in 5 days
View Details
NAICS: 325998
New
Federal
Microbiological media purchase order for Clinical Microbiology laboratory.
Solicitation # 36C26027Q0104
The Department of Veterans Affairs Network Contracting Office 20 is seeking sources for a microbiology testing media purchase order to support the Seattle Division of the VA Puget Sound Medical Center. This requirement covers a wide range of critical supplies for identifying pathogenic organisms in veteran patients, including long shelf-life products like Oxidase and Indole, perishable selective agar, biochemical test kits, and ATCC organisms mandated by the College of American Pathologists for quality control. The contract is structured with a base year running from February 1, 2027, to January 31, 2028, followed by four subsequent one-year option periods ending January 31, 2032. Deliveries are to be made to the Microbiology Lab in Seattle, with weekly shipments typically scheduled for Tuesdays and individual requests fulfilled as available. Due to the perishable nature of many items, the vendor must provide tracking information, and the cost of next-day delivery for all perishable goods must be included in the individual item price. All temperature-liable products require immediate refrigeration upon delivery. Invoicing is processed through the Austin Automated Payment System in Texas, and the vendor must provide SDS sheets for all media upon request. This sources-sought notice specifically looks for capable sources, including qualified SDVOSB/VOSB entities, with a response deadline of November 10, 2026.
All Other Miscellaneous Chemical Product and Preparation Manufacturing

POSTED

2 days ago

DEADLINE

in 12 days
View Details
NAICS: 238220
New
Federal
Z1DA--CON-NRM-668-22-106 Correct Domestic Water System
Solicitation # 36C26027R0014
Solicitation 36C26027R0014 is a negotiated request for proposals for the Department of Veterans Affairs to correct domestic water system deficiencies in Buildings 1 and 12 at the Mann-Grandstaff VA Medical Center in Spokane, Washington. The project is 100% set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 238220, with an estimated contract magnitude between $1 million and $2 million. The primary objective is to modify hot and cold potable water distribution systems to comply with VHA Directive 1061 for the prevention of scald injuries and Health Care-Associated Legionella Disease. The scope includes all labor, materials, and equipment, with a specific requirement to flush potable water dispensing fixtures twice weekly from installation until final acceptance. The period of performance is 275 calendar days from the Notice to Proceed. The government will utilize a Best Value tradeoff process for award, prioritizing technical experience and past performance over cost. Technical evaluations will favor offerors with demonstrated experience in phasing and Infection Control Risk Assessment (ICRA) within 24-hour operational emergency rooms. Proposals must be submitted in three separate volumes—Technical, Past Performance, and Price—by November 23, 2026. Awardees must provide performance and payment bonds, adhere to Davis-Bacon Act wage determinations, and comply with Buy American requirements. Additionally, the contractor must maintain strict confidentiality regarding sensitive information and provide a one-year warranty on all materials and installation.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

2 days ago

DEADLINE

in about 1 month
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS