J061--Sources Sought - Generator Testing, Maintenance, and Repair Services Black Hills Healthcare System

Closed
36C26326Q0697Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811210
New
SLED
Statewide Standby Generator, ATS & UPS Preventive Maintenance Services
Solicitation # BD-27-1107-FREG5-ACCOU-133129
The Massachusetts Trial Court, through the Office of Court Management, Facilities Management & Capital Planning, is soliciting bids for statewide preventive maintenance, inspection, operational testing, load-bank testing, repair, and emergency services for standby generators, automatic transfer switches, and uninterruptible power supply systems. The contract is structured into five independent regional award groups, with each region being awarded to the lowest responsible and eligible bidder. The initial performance period is 32 months, running from November 1, 2026, to June 30, 2029, with two optional one-year renewals available through June 30, 2031. Bidders must submit their response packages electronically via the COMMBUYS portal by September 30, 2026, including a bid deposit of at least 5 percent of the greatest possible bid amount per region. Award evaluation is based on bid responsiveness, eligibility, and the lowest evaluated regional price, with a requirement that contractors demonstrate the capacity to perform in multiple regions simultaneously if awarded more than one. Contractors must adhere to NFPA 70B, the Massachusetts Comprehensive Fire Safety Code, and the Massachusetts Electrical Code, and are required to provide detailed electronic service reports as a condition of payment. Payments are processed via Electronic Funds Transfer through the Comptroller's system, typically 45 days from invoice receipt.
FREG5 - Facilities Management & Capital Planning - Region V

POSTED

1 day ago

DEADLINE

in 18 days

AI Contract Overview

Show more

The Black Hills Healthcare System is seeking vendors to provide semi-annual generator testing, maintenance, and emergency repair services for critical emergency power systems at its Fort Meade and Hot Springs VA Medical Centers, with potential service to mobile units in Rapid City. The scope includes comprehensive preventive inspections and load bank testing of multiple emergency generators across several buildings, including high-capacity systems such as a 2000KW, 12,470-volt generator at Building 155 and smaller units ranging from 10KW to 400KW on various platforms from Cummins, Marathon, Generac, Onan, Kubota, and John Deere. Inspections are to be conducted twice yearly during October/November and May/June, with detailed reports submitted within 30 days, and annual load bank testing must adhere strictly to NFPA 110 standards with specified load profiles. Emergency repair services require a four-hour response time, and contractors must be prepared to provide standby backup generators while primary units are out of service. Any repairs exceeding $2,500 require formal written approval and a bilateral supplemental agreement, while minor repairs may be authorized via Government Purchase Card. Fluid testing must be performed by third-party laboratories and reported to the Contracting Officer’s Representative, and all work must comply with security, privacy, and HIPAA regulations as outlined in VA policy 6500.6 Appendix C and NARA guidelines. All personnel must complete required training and sign documentation, and contractors are prohibited from leaving generator systems in non-automatic or unattended mode without explicit approval. Contractors must respond to this market research solicitation by May 26th, 2026, via email to Joseph Bloomer, including their organization’s socioeconomic classification, identification of any existing government contracts under which the services could be ordered, and disclosure of any planned subcontracting, including percentage and scope. While no contract award will result from this solicitation, responses are critical to shaping future procurement strategy and may trigger application of FAR 52.219-14 or VAAR 852.219-75 subcontracting limitations depending on the vendor’s size and veteran-owned status. The work will occur at designated VA facilities in Fort Meade and Hot Springs, South Dakota, during standard business hours, with after-hours work requiring coordination. Contractors are responsible for all tools, parts, fluids, labor, and diagnostic capabilities, and must submit written corrective action plans if the same issue recurs on a

General Info

Seeking vendors for semi-annual emergency generator maintenance at SD VA Medical Centers, no contract awarded.

Agency

Department Of Veterans Affairs → Network Contract Office 23 (36C263)View Agency

NAICS

811210 - Electronic and Precision Equipment Repair and MaintenanceView NAICS

Place of Performance

Black Hills HCS Fort Meade & Hot Springs Campuses, Fort Meade, SD, 57741, USA

Set-Aside

NONE

Documents

(1)

Sources Sought - Generator Testing, Maintenance, and Repair Services Black Hills Healthcare System 36C26326Q0697

DOCXsources-sought

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 23 (36C263)
Contacts1 person available
OfficeSaint Paul, MN, 55101, USA
Organization / Agency
Department Of Veterans Affairs → Network Contract Office 23 (36C263)
View Agency Profile
Office AddressSaint Paul, MN, 55101, USA
Contacts
Joey BloomerContracting Officer

Full Description

Show more
The Black Hills Healthcare System requires Generator Testing, Maintenance, and Repair Services in accordance with the draft Statement of Work (SOW) below. This is a sources sought/proof of capability solicitation looking for vendors to perform the services per the SOW for market research purposes. No award of a contract will be made from this announcement. If you are a vendor that can complete the work described in the SOW with competitive pricing, please send your contact and organization information with a descriptive proof of capability to: Joey Bloomer, joseph.bloomer@va.gov on or before May 26th, 2026. Only emailed responses will be considered. Additionally, provide answers as appropriate to the following questions in the table below with your response to this sources sought. Failure to respond to the following questions may affect the acquisition strategy. 1. Identify your organization's socio-economic category.
2. State whether any of the requested services may be ordered against a government contract awarded to your organization (e.g Federal Supply Schedule (FSS), General Services Administration (GSA), etc.).
3. State if subcontracting is contemplated for this requirement and what percentage of the work will be subcontracted and for what tasks.
  *If applicable, VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction, will apply to the potential solicitation if set-aside for Veteran Owned Small-Businesses or Service Disabled Veteran Owned Small-Businesses.* *If applicable, FAR 52.219-14 Limitations on Subcontracting, will apply to the potential solicitation if set-aside for Small-Businesses.*
STATEMENT OF WORK Semi-Annual VA BHHCS Emergency Generator Testing and Maintenance
1. SCOPE Provide semi-annual preventive maintenance inspections and services on emergency generators at the VA medical Centers at Ft Meade and Hot Springs, South Dakota and VA clinic in Rapid City (if mobile units are in place there). The Fort Meade campus has a 12470-volt primary system that includes various secondary voltages and both normal and emergency power sources. Inspection reports from attachments A & B to be provided to facilities POC s within 30 days of service.
2. CONTRACT POC S FOR SCHEDULING WORK AND COORDINATION ARE AS FOLLOWS: Fort Meade VAMC: Delane Erickson, Operations Supervisor, Phone: 605-720-7134 Hot Springs VAMC: Dan Cerveny, Maintenance Supervisor, Phone 605-745-2268
3. EQUIPMENT Fort Meade Emergency Generator equipment included in the scope of work is as follows: A. Bldg. 113 Emergency Generator Manufacturer: Cummins/ 750 KW/ 480V Generator Model; DQCB-1641706 / Serial Number: K160128689 Engine Model: QSK23G7 / Serial Number: 85002334
B. Bldg. 148 Emergency Generator Manufacturer: Cummins/ Onan/ 125 KW/ 480V Generator Model: DSGAB- 1321187 / Serial Number: B130456361 Engine Model: QSB7 G5 NR3 / Serial Number: 73494119
C. Bldg. 145 Emergency Generator Manufacturer: Cummins/ 250 KW / 208V Generator Model: DQDAA-1660802 / Serial Number: L160128689 Engine Model: QSL9-G7 / Serial Number: 74068824
D. Bldg. 137 Generator Manufacturer: Cummins/ Onan/ 100 KW/ 208V Generator Model: DSGAA- 1321189 / Serial Number: B130456362 Engine Model: QSB7 G5 NR3 / Serial Number: 73493506
E. Bldg. 160 Generator Manufacturer: DMH/ 165 KW/ 480V Generator Model: 200CL3 / Serial Number: 94-45-74-1 Engine Model: LTA-1062/ Serial Number: 34737406
F. Bldg. 155 Main Station Generator Manufacturer: Marathon / 2000KW / 12470V Generator Model: 1020FDH1242 / Serial Number: WA-6003864-0717 Engine Model: CD2000SX6T2 / Serial Number: 179811-1-1-1108
G. Bldg. T296 Fire Station Generator Manufacturer: Cummins/ Onan/ 16.8KW/ 240V Generator Model; DSKCA-193329 / Serial Number: L090070761
3. Hot Springs VAMC Emergency Generator equipment included in the scope of work is as follows: A. Bldg. 10 Emergency Generator Manufacturer: Marathon MTU/ 250KW/ 480V Generator Model: 573RSL4033/ Serial Number: MT-0132187-0223 Engine Model: 10V1600 / Serial Number: 95010501432
B. Bldg. 12 Emergency Generator Manufacturer: Generac/ 400KW/ 208V Generator Model: 433RSL4021/ Serial Number: LM-239579-0701 Engine Model: OA8829/ Serial Number: 8DC9-446846
C. Bldg. 18 Emergency Generator Manufacturer: Onan/ 230KW/ 208V Generator Model: 230DFAB / Serial Number: A980673745 Engine Model: LTA10-G1 / Serial Number: 12079
F. Bld. 66 Emergency Generator Manufacture: Cummins/ 125KW/ 208V Generator Model 125 DSGAB Engine Model: QSB7-G5 NR3
* Can be at any VA Medical Center locations: A. Mobile MRI Emergency Generator Manufacturer: Kubota Generator Model: V3800-T Serial Number: 2JS2095 45 KW / 480V B. Mobile CT Emergency Generator Manufacturer: John Deere Generator Model: 4045 / 100K / 480V
C. Mobile Morgue Trailer Emergency Generator Manufacturer: Kubota Generator Model: GL11000-USA Serial Number: 10 KW / 240V
4. SEMI-ANNUAL INSPECTIONS Semi-annual inspections shall be completed within October/November (Attachment A) and within May/June (Attachment B), and inspection reports shall be provided to the VAMC POC s within 30 days of completion of work. Work shall be scheduled 7 days in advance of planned work to minimize disruption to the facility. The scope of October/November inspections and testing shall include all work outlined in Attachment A. The scope of May/June Inspections will include all work outlined in Attachment B.
5. ANNUAL LOAD BANK TESTING
Annual load bank testing included in Attachment A shall be accomplished in accordance with NFPA 110 (99) Sec 6-4.2.2. The testing shall be documented, and supplemental loads included at 25 percent of the name plate rating for 30 minutes. Followed by 50 percent of the nameplate rating for 30 minutes. Followed by 75 percent for 1 hour. All emergency generators will be load-bank tested annually. The Main station generator BLDG. 155 will be load-bank tested every other year starting with the first option year of the contract. Automatic Transfer Switches will be included in the semi-annual test for the Emergency Power Supply System (EPSS). This would consist of a transfer without load and resistance or amp drop reading depending on the state of the contacts.
6. CONTRACTOR RESPONSIBILITIES All supplies, fluid testing, filters, fluids, parts, tools, and labor will be supplied by the Contractor. Contractor is to diagnose other or larger problems and present quotes to the POC for approval, before additional work is conducted. Fluid testing will need to be conducted by 3rd party tester semiannually, and the report shall made to POC/COR within 30 days of service. The Contractor should provide priority for repairs to the BHHCS VA Emergency Generators and ATS Switches.
5. WORK HOURS Planned maintenance and testing shall occur Monday through Friday, 8:00 AM to 4:00 PM, excluding federal holidays. If the work needs to be partly outside of standard VA business hours, to minimize patient impact, scheduling with the COR/POC will be required. Emergency services shall be available with a four (4) hour response time.
6. CHECK-IN PROCEDURE Technicians must report to the contract POC at their respective location prior to beginning work.
7. SITE ADDRESSES The addresses of the VA Black Hills Health Care System is listed below. Hot Springs VAMC is located at 500 5th Street, Hot Springs, South Dakota 57747 Fort Meade VAMC is located at 113 Comanche Road, Fort Meade, South Dakota 57741
8. REPAIRS Any necessary repair/replacement parts or services created by testing of the equipment as part of this contract will be furnished/paid for by the facility and these repairs will be completed on an emergency basis. This designation will require the Contractor to stand down during repairs and to continue testing as soon as practical after the repairs have been made. During the time that the generator remains out of service, the Contractor will be required to connect and maintain their standby/backup generator and associated automatic connection equipment. The backup emergency generators shall provide service until all emergency repairs have been completed, and the successful load bank testing procedures have reached a satisfactory conclusion. The Contractor s responsibility for additional rental outlays due to this requirement shall be limited to standby service. Minor repairs shall include, but not be limited to such items as loose bolts, loose or broken lugs, wiring terminals, malfunctioning targets, dirty/high resistance connections, etc. and shall be corrected on site during testing if possible. The POC/COR can authorize requests for non-emergency repairs if they are submitted in writing and do not exceed $2,500, executed through Government Purchase Card (GPC) transaction. All requests for repairs shall be in writing with a detailed explanation, cost of parts, labor and all associated costs to complete repairs. Any repair that exceeds the $2,500 threshold shall require Contracting Officer approval prior to the ordering of parts or execution of services. The Contractor shall submit their request for repair to the CO and POC/COR. The repair quote shall be a detailed explanation and breakdown of costs. Authorized repairs shall be executed through a bilateral supplemental agreement on the contract between both parties if service costs exceed $2,500.
11. EMERGENCY REPAIRS Contractor shall provide a four-hour response time for call back service from the time a call for service is made by the Contracting Officer, Facilities Management Officer, POC/COR, or their designees. Contractor will be on site within this four-hour time frame, unless the situation isn t considered an emergency, and another mutually agreed upon time will meet the government s needs. The Contractor must be able to properly troubleshoot and diagnose all aspects of emergency generators. The Contractor shall provide all labor, materials and equipment for the emergency callback services for all generators at the Hot Springs and Fort Meade (Sturgis) VA Medical Centers, if the supplied quote is selected, and in accordance with specifications included in this scope of work. The Contractor shall submit a written plan of action to the Contracting Officer, or POC/COR, whenever unresolved problems occur three times on the same generator. Whenever the same problem recurs on the same generator three times, the VA requires an analysis of the corrective action required to resolve the problem. When generator systems fail, and require emergency repairs, the technician s Supervisor shall provide the BLACK HILLS HCS with a written statement and itemized quote assessing the generators system failure and that they have verified the generator system has been properly diagnosed and concur with the technician s assessment. The VA reserves the right to enlist a third-party expert to provide a 2nd opinion. It is the responsibility of the Contractor to reassess their proposed repairs and either reaffirm or correct their proposal based on the expert s notes. The reassessment shall include at a minimum, a substantive analysis of the third-party expert s points that contradict the Contractor s original conclusion. This reassessment shall be submitted within 5 business days of receipt of the third-party expert s opinion.

12. COORDINATION The contractor shall be responsible for coordinating any necessary utility system shutdowns and returning these systems to operational mode. In addition, the contractor must notify VA Facilities Management Service COR before any systems are shut down and when these systems are put back into full service. The contractor will not be permitted to leave any emergency generator system or component in a non-automatic connected mode or unattended mode during any portion of the testing. Should such non-automatic circumstances exist the contractor must have the approval of the Chief, Facilities Management Service. The contractor shall be responsible for any damage due to negligence to equipment that is created while performing the services required in this contract. Equivalent loads used for testing shall be connected such that they can be automatically replaced with emergency loads in case of failure of the primary power source.
13. TRAINING, SECURITY AND NARA REQUIREMENTS ALL Contractors on-site shall complete required training. Each contractor is required to print, review, and sign the attached TMS 20939 document. Contract owner/supervisor must send signed TMS 20939 documents to the contract COR.
6500.6 Appendix C Security and NARA PRIVACY-HIPAA CLAUSE a. ALL Contractors on-site shall read and comply with attached 6500.6 Appendix C Security and NARA PRIVACY-HIPAA CLAUSE documents.
See Attachment C for Security and Attachment D For NARA.

More opportunities from Department Of Veterans Affairs → Network Contract Office 23 (36C263)

Same awarding agency

NAICS: 236220
New
Federal
PN: 438-21-403, Renovate First Floor Kitchen (SF)
Solicitation # 36C26326B0020
Solicitation 36C26326B0020 is a Firm-Fixed-Price contract opportunity issued by the Department of Veterans Affairs, Network Contracting Office 23, for project 438-21-403 to renovate the first floor kitchen at the Sioux Falls VA Medical Center in South Dakota. This project is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220, with an estimated construction magnitude between 10 million and 20 million dollars. The scope of work involves comprehensive architectural, structural, mechanical, and electrical improvements, including the demolition of existing walls, floors, and ceilings, site work such as excavation and paving, and the installation of owner-furnished equipment. A critical requirement of the project is the phased execution of construction to ensure the existing second-floor kitchen remains operational for inpatient meals. The performance period is 550 calendar days from the Notice to Proceed. Bidders must be registered in the System for Award Management (SAM) and provide a bid guarantee on Standard Form 24 of at least 20 percent of the bid price, capped at 3 million dollars. Award will be based on the responsible bidder offering the most advantageous price. The contractor is required to adhere to OSHA and VA regulations, the Davis-Bacon Act for prevailing wages, and the 2010 ADA Standards for Accessible Design. Final acceptance is contingent upon the submission of warranty certificates, project record documents, and the completion of factory-trained instruction for equipment operation and maintenance.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in about 1 month
View Details
NAICS: 621991
New
Federal
6506--RFQ - Blood, Blood Products and Services In Support of the Nebraska Western-Iowa VA Health Care System.
Solicitation # 36C26326Q1098
The Department of Veterans Affairs, specifically the Omaha VA Medical Center within the Nebraska Western-Iowa Health Care System, is seeking a single-award, Firm Fixed Price, IDIQ contract for the collection, processing, storage, and delivery of human blood components, derivatives, reference laboratory testing, and apheresis services. The contract consists of a base year running from October 1, 2026, to September 30, 2027, followed by four one-year ordering periods. All blood products must be domestic end items drawn and processed within the United States and must be provided by an FDA-registered source complying with American Association of Blood Banks (AABB) standards and Title 21 of the Code of Federal Regulations. The contractor is responsible for ensuring all products are properly packaged and insulated to maintain required temperatures during transport to the Omaha facility, adhering to all federal and state DOT requirements. Award decisions will be based on a comparative evaluation of price, technical capability, and past performance. Offerors must provide a Buy American Certificate and comply with specific VA cybersecurity and data breach reimbursement clauses. All quotes must be emailed to Joseph Bennett by 5:00 PM CT on September 20, 2026, and must include the solicitation number 36C26326Q1098 in the subject line.
Blood and Organ Banks

POSTED

1 day ago

DEADLINE

in 8 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS