J065--ANNUAL MEDICAL GAS TESTING Loma Linda VA POP: 12/01/2026 - 11/30/2031
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The Loma Linda VA Health Care System is conducting market research through a sources sought announcement to identify qualified small businesses capable of providing annual medical gas distribution system inspections. The objective is to ensure patient safety and compliance with NFPA 99, OSHA, and ASSE 6000 standards. The scope of work includes the inspection, testing, and verification of medical gas sources, master and area alarm panels, zone valve boxes, patient terminal outlets, and emergency supply connections across multiple facility buildings. Services must be performed by licensed ASSE 6020 inspectors and ASSE 6030 verifiers. The anticipated contract structure is a base year plus four option years, with the place of performance located in Loma Linda, California. The government is specifically seeking interest from Service-Disabled Veteran Owned Small Businesses, though other small business categories are encouraged to respond. Interested parties must submit a comprehensive capability statement and company details to the designated contract specialist by September 30, 2026. This notice is for planning purposes only and does not constitute a formal solicitation or a commitment to award a contract.
General Info
Agency
NAICS
Place of Performance
Department of Veterans Affairs Loma Linda VA Health Care System, Loma Linda, AZ, 92357, USASet-Aside
Documents
(1)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
*******DRAFT*******DRAFT******DRAFT*******DRAFT*******
D.1 STATEMENT OF WORK
TITLE: VA Loma Linda Healthcare System s (VALLHCS) Annual Med Gas Inspection BACKGROUND INFORMATION: VA Loma Linda Healthcare System s (VALLHCS) requires a new maintenance and inspection contract for Medical Gas Distribution System. The Medical gas distribution system must undergo routine source and pipeline system inspections and maintenance to ensure continuous patient safety. PARTS and EQUIPMENT LIST:
PARTS QUANTITY
OBJECTIVES: VA Loma Linda Healthcare System s (VALLHCS) Medical gas distribution system inspections shall comply with NFPA99 (Health Care Facilities Code), OSHA Life safety fire code, and the ASSE 6000 standard. They require annual central supply checks, routine alarm tests, and specialized third-party inspections by certified ASSE 6020 Inspectors. The services performed shall conform to industry standards and this statement of work (SOW) and lockout and tagout procedures are to be done according to (OSHA Standard29 CFR 1910.147) VA Loma Linda Healthcare systems Policies and Regulations.
SCOPE: Contractors shall provide all labor, personnel, supplies, equipment, tools, materials, supervision and other necessary items. Inspection, testing and verification are mandatory for medical gas work and will be performed by licensed ASSE 6020 Medical Gas Inspectors and ASSE 6030 Medical Gas Verifiers. Contractor shall perform Annual Medical Gas Distribution System Inspection on all Sources, Alarms, Zone Valves, and Patient Terminal Outlets / Inlets and bulk oxygen system. Including Areas as follows: Main Hospital First Floor: CLC, CLC Palliative Care, CLC Rehab, 1SW, Mod 3, Emergency department, Second Floor: ICU: 2SW, 2SE, Third Floor: OR 1 through 8, 3F-14, 3F-16, 3D-72, Recovery Room, SICU, X-Ray, MRI, Short Stay, G.I. Labs, 3NW, 3NE, 3SW, 3SE Fourth Floor: 4NW, 4NE, 4SW, 4SE, Nuclear Med, Dialysis, Blood Laboratory,
Oncology Building 31 Eye Clinic Building 32 Audiology Building 30 List of items provided for inspection: Medical Gas Sources Medical air compressors, vacuum pumps, gas manifolds, and any other device used to deliver medical gases to patients. 1.Inventoried by location. 2.Leak checked and documented. 3.Recommendations to comply with NFPA 99, 2024 edition Health Care Facilities Code. Master Alarm Panels Alarm panels are located at two separate locations throughout the facility. These panels monitor conditions directly from the medical gas sources. 1.Inventoried by location 2.Tested by removing existing pressure switches and other sensing devices to test the actuation points. No interruption of service is necessary if each device is mounted on code compliant demand fittings. 3.Verify proper points are being monitored at each panel. 4.Verify each panel is in the proper location. 5.Verify proper labeling. Area Alarm Panels Alarm panels that are located throughout the facility monitor medical gas pressures for the area only. 1.Inventoried by location. 2.Tested by lowering pressure in each zone for each gas and documenting the alarm point. 3.Verify proper location. 4.Verify proper labeling. Zone Valve Boxes Accessible valves typically found in a corridor covered by a plastic window used mostly for emergency purposes. 1.Inventoried by location. 2.Checked for leakage from packing, flange, and gauge port using oxygen safe leak detector. 3.Verify proper labeling. 4.Verify proper locations. Medical Gas Outlets/Inlets Connection points for each gas are located mostly in-patient areas. 1.Inventoried by location in each room or area inspected left to right and then top to bottom. 2.Complete an operational pressure test on each outlet and document pass/fail. (Test Parameters per NFPA 99, 2024 edition) 3.Check function of outlet/inlet and latching mechanism. 4.Check for leakage with equipment and without equipment attached. 5.Document connection type and outlet/inlet manufacturer. Oxygen Particulate Analysis Particulates are often found in existing medical gas systems due to improper installation methods that were used in the past. 1.Samples are taken on each floor in each building. Medical Air Dewpoint Analysis Moisture is removed from medical air systems at the source. Periodic Analysis of moisture throughout the facility is important to prevent possible contamination. 1.Samples are taken on each floor in each building. 2.A sample will be taken at the medical air source to compare building samples. Emergency Oxygen Supply Connection Box This box is typically mounted on the outside of a facility to facilitate the back feeding of the oxygen system if there is an interruption in service. 1.Inventoried by location. 2.Check existing location for proper compliance. 3.Check existing piping arrangements to ensure proper order of components. 4.Check to make sure box is secured. Testing to ensure all medical gas booms, and columns are leak free Most operating rooms and procedure rooms have some sort of device to help clinical personnel use the medical gases in the middle of the room by the patient. These devices are either medical gas booms or columns. The hoses and threaded connections inside these devices need to be checked periodically to ensure that there are no leaks. 1. All hoses and secondary equipment were removed from the outlets on each boom and column. 2. A test pressure for each system was observed and documented. 3. All medical gas valves were shut over a period of 10 minutes. 4. After the test period of 10 minutes passed the pressure was observed once again. 5. Any pressure drop was recorded. 6. Recommendations will be made to find existing leaks and to make repairs. Facilities responsibility: A. The facility shall coordinate with all departments to notify of the medical gas/vacuum system inspection and or repairs to be completed. B. The facility shall supply Inspecting personnel with facility maintenance personnel to unlock secured areas that have medical gas/vacuum systems, or a master key may also be supplied to complete inspection services.
REPORTS:
The contractor will annotate compliance with ASSE 6000, 6020 and 6030 Medical Gas specifications and requirements by submitting a detailed PM report to the Contracting Officer s Representative (COR) along with pictures for each equipment, after PM is completed. The reports shall be submitted to COR, within 14 days of work completion. The contractor shall provide additional reports as required by the COR. The contractor s report shall show the information listed below. The report shall contain, at a minimum, any other information required by the COR and all applicable NFPA and Joint Commission and OSHA specifications, the following: Date of P.M. Time of P.M. Identification of the equipment descriptions, manufacturer, and serial number Location of equipment under P.M. or repair Probable cause of repairs Correction action (servicing, repair or replacement) Who was notified? Comments and recommendations. Completion date Contractor shall complete scheduled preventive maintenance service, inspection and repairs to NFPA and Joint Commission and OSHA requirements for the Medical Gas Distribution System. OVER AND ABOVE REPAIR:
Upon discovery of over and above repairs or unforeseen requirements, Contractor shall immediately notify the POC. Parts shall not be procured, nor installation or repairs initiated until approval is obtained from the Contracting Officer and appropriate Facilities Staff/POC. Charges for repair, labor and parts shall originate only when required and upon prior approval being granted by the Contracting Officer. Any additional work performed must be by licensed ASSE 6010 Medical Gas System Installers and ASSE 6040 Medical Gas System Maintenance Personnel.
PERIOD OF PERFORMANCE:
Base Plus Four from performance start date. Work may be scheduled during the day or night (Depending on load demand), Monday thru Friday and/or Saturday thru Sunday. Daytime hours: 6 am to 4 pm Evening hours: 4 pm to 4 am Contractor shall initiate work within 2 weeks of being contacted by the designated Contracting Officer s Point of Contact (POC) or designee. Work shall be scheduled through the POC or designee, who will coordinate with VALLHCS staff. Timelines are subject to change due to VALLHCS operational requirements.
PLACE OF PERFORMANCE:
VA Loma Linda 11201 Benton St. Loma Linda, CA 92357
LICENSING REQUIREMENTS:
Offeror must possess a 30-hour Occupational Safety and Health Administration (OSHA) safety card. ASSE Medical Gas Verifier 6030 ASSE Medical Gas inspector 6020
SPECIFIC REQUIREMENTS: Contractor shall schedule start date with POC or designee five (5) business days in advance. Contactor personnel shall have valid Loma Linda PIV badges before starting work. Contractor shall coordinate energy source LOCK OUT /TAG OUT procedures with VALLHCS Electrical Supervisor before starting work. When work is complete, Contractor shall notify the VALLHCS Electrical Supervisor that energy sources will be restored and require verification. Contractor s supervisor or lead technician are to check in with VALLHCS Electrical Supervisor, or in their absence, with Graphics Control prior to work each day. Contractor shall conform to the following standards, policies, regulations, governing agency, and any other local, state, or Federal guidelines that are not listed here. OSHA 29CFR Regulations, www.osha.gov NFPA 99, www.nfpa.org Chapter 5 Gas and Vacuum Systems 5.1 Category 1 Piped Gas and Vacuum Systems 5.2 Category 2 Piped Gas and Vacuum Systems 5.3 Category 3 Piped Gas and Vacuum Systems ASSE
AUTHORIZED SERVICES:
Only those services specified herein are authorized under this contract. Before permitting and/or performing any service of a non-contract nature, the Contractor shall advise the CO of the reason (s) for the additional work and/or service. The Contractor is cautioned that only the CO or his/her designee may authorize additional service that are within the scope of this contract and that reimbursement shall not be made unless prior authorization is obtained from the CO. All changes to the contract shall be issued through a contract modification in writing from the CO to the Contractor.
DELEGATION OF AUTHORITY:
No additional service shall be provided without the approval from the Contracting Officer (CO) or his/her designee of this contract. The Contractor shall not accept any instructions issued by any other person(s) other than the CO or his/her delegated representative acting within the limits of his/her authority.
GOVERNMENT-FURNISHED EQUIPMENT (GFE) GOVERNMENT FURNISHED INFORMATION (GFI):
No Government equipment will be used by the Vendor.
RECOGNIZED HOLIDAYS:
The following is a list of all Government recognized holidays:
In accordance with 5 U.S.C. 6103, Executive Order 11582 and Public Law 94-97 the following National holidays are observed and for the purpose of this contract are defined as Legal Federal official holidays :
New Year s Day: January 1 Martin Luther King s Birthday: Third Monday in January President s Day: Third Monday in February Memorial Day: Last Monday in May Juneteenth Independence Day: June 19 Independence Day: July 4 Labor Day: First Monday in September Columbus Day: Second Monday in October Veterans Day: November 11 Thanksgiving Day: Fourth Thursday in November Christmas Day: December 25
If a holiday falls on Sunday, the following Monday shall be observed as the legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.
CONTRACTOR EMPLOYEES AND BADGES:
Contractor personnel shall present a neat appearance and be easily recognized as Contractor employees. Examples: wearing of distinctive clothing such as uniform, badges, patches, etc. All contractor personnel shall be required to wear VA provided identification (I.D.) badges above the waist at all times while on the VA grounds. Contractor shall be required to coordinate with the COR to obtain the VA provided I.D. badges for all staff. All VA provided I.D. badges shall be returned at the end of the contract or upon completion of service. Failure to wear ID badges may result in removal from any of the VA facilities and/or otherwise referred to Government property.
SAFETY AND PPE EQUIPMENT:
Personal Protective Equipment shall be provided for each Contractor employee by the Contractor. Possession of weapons are prohibited.
SMOKING and VAPING POLICIES:
Smoking and vaping are prohibited on Government property.
PARKING:
It is the responsibility of Contractor personnel to park only in designated parking areas. Parking information is available from the VA Security Service. The VA shall not invalidate or make reimbursement for parking violations of the Contractor's personnel under any circumstances.
COMPLAINTS:
Contractor shall promptly and courteously respond to complaints within three (3) working days to the COR. Including complaints brought to the contractor s attention by the CO. Contractor shall maintain a written record of all complaints, both written and oral showing the identity of the individual, the nature of the complaint, and contractor s response. Contractor shall permit the Government to inspect the written records of complaints upon reasonable notice from the CO.
Notice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov. Additionally, all Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be certified by the Small Business Administration; Veteran Small Business Certification, (VetCert) https://veterans.certify.sba.gov/. All interested Offerors should submit information by e-mail to: catherine.fernandezpedernera@va.gov .
All information submissions to be marked Attn: Catherine Fernandez, Contract Specialist and should be received no later than 10:00 AM PST on September 30, 2026.
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
Same awarding agency
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS
