Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on June 5, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J066--Preventive Maintenance Services for Brand Name or Equal To Thermo Fisher for Fort Harrison VA Medical Center (FHVAMC)

Closed
36C25926Q0517Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The U.S. Department of Veterans Affairs, through Network Contracting Office 19, is conducting market research to identify qualified sources for preventive maintenance services on specific Thermo Fisher branded equipment at the Fort Harrison VA Medical Center. The requirement covers maintenance for six pieces of laboratory equipment: Thermo Fisher SlideMate (two units), PrintMate AS, Revos, Excelsior AS, and HM 340E Microtome, all with an estimated initial performance period from July 31, 2026, to July 30, 2027, and the potential for four optional one-year renewals. Contractors must provide comprehensive preventive maintenance services in strict adherence to manufacturer guidelines, including routine inspections, cleaning, leak and corrosion checks, repair or replacement of worn components, calibration of instruments and sensors, verification of control and safety systems, performance testing to ensure operational standards, and execution of electrical safety measurements. Documentation is critical, requiring detailed records of all scheduled and unscheduled maintenance activities, including parts replaced, and submission of two copies of the contractor’s preventive maintenance procedures manual to the Contracting Officer Representative within fifteen days of award or before the first servicing, whichever comes first. Contractors must also provide advance notice of all scheduled visits to the Pathology and Lab Contracting Officer Representative and be available for emergency maintenance as needed. Responses are requested through a Sources Sought Notice, which is strictly for market research and does not constitute a solicitation or obligation to award a contract. All submissions must include mandatory information such as company name, address, Unique Entity ID, contact details, business size certifications, FSS/GSA contract status, and pricing model preference (firm-fixed price), along with a completed market research questionnaire and a capabilities statement outlining the proposed solution. Respondents must disclose the domestic versus foreign content percentage of their proposed products under the Buy American Act and comply with Nonmanufacturer Rule requirements if applicable. The North American Industry Classification System code identified for this requirement is 811210 for Electronic and Precision Equipment Repair and Maintenance, with a small business size standard of $34 million, though contractors may propose alternative NAICS codes. Submissions are limited to eight pages and must be emailed to Devin Reichert at [email hidden] no later than 4:00 p.m. Mountain Time on June 12, 2026. All sensitive information must be clearly marked as proprietary, and responders bear full responsibility for their own costs and expenses.

General Info

VA seeks contractors for preventive maintenance on Thermo Fisher equipment at Fort Harrison VA Medical Center.

NAICS

811210 - Electronic and Precision Equipment Repair and Maintenance

Place of Performance

Fort Harrison VA Medical Center 3687 Veterans Dr., CO

Set-Aside

NONE

Documents

1

Sources Sought Notice 36C25926Q0517 Preventive Maintenance Services Thermo Fisher FHVAMC

DOCX, High priority: read this firstsources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 19 (36C259)
Contacts1 person available
OfficeGreenwood Village, CO, 80111, USA
Office AddressGreenwood Village, CO, 80111, USA
Contacts
Devin ReichertContract Specialist

Full Description

Show more
Sources Sought Notice - Preventive Maintenance Services for Brand Name or Equal To Thermo Fisher for Fort Harrison VA Medical Center (FHVAMC) Disclaimer: This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
Information Requested from Industry:
In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List. Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.
Description of Requirement: The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Preventive Maintenance Services for current Government Owned Equipment as follows: Thermo Fisher Excelsior Tissue Processor, Thermo Fisher REVOS Tissue Processor, Thermo Fisher HM 340E Microtome, Thermo Fisher SlideMate & Thermo Fisher PrintMate Brand Name or Equal To for the Fort Harrison VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.
Requirements for Services:
Item No. Item Description 1 Brand Name or Equal To Thermo Fisher SlideMate Estimated Period of Performance July 31st, 2026 July 30th, 2027, plus four subsequent option years 2 Brand Name or Equal To Thermo Fisher SlideMate Estimated Period of Performance July 31st, 2026 July 30th, 2027, plus four subsequent option years 3 Brand Name or Equal To Thermo Fisher PrintMate AS Estimated Period of Performance July 31st, 2026 July 30th, 2027, plus four subsequent option years 4 Brand Name or Equal To Thermo Fisher Revos Estimated Period of Performance July 31st, 2026 July 30th, 2027, plus four subsequent option years 5 Brand Name or Equal To Thermo Fisher Excelsior AS Estimated Period of Performance July 31st, 2026 July 30th, 2027, plus four subsequent option years 6 Brand Name or Equal To Thermo Fisher HM 340E Microtome Estimated Period of Performance July 31st, 2026 July 30th, 2027, plus four subsequent option years
SOW Requirements:
Maintenance and Inspection Activities: Perform routine checks and maintenance according to the manufacturer s guidelines. Inspect and clean all components of the Thermo Fisher Excelsior Tissue Processor, Thermo Fisher REVOS Tissue Processor, Thermo Fisher HM 340E Microtome, Thermo Fisher SlideMate & Thermo Fisher PrintMates Brand Name or Equal To. Check for any leaks, corrosion, or wear and tear, and repair or replace parts as necessary. Verify the proper functioning of control systems and safety features. Test the Thermo Fisher Excelsior Tissue Processor, Thermo Fisher REVOS Tissue Processor, Thermo Fisher HM 340E Microtome, Thermo Fisher SlideMate & Thermo Fisher PrintMate Brand Name or Equal To performance and ensure it meets the specified operational standards. Calibrate all instruments and sensors to ensure accurate readings. Must provide documentation and shall include detailed descriptions of the scheduled and unscheduled maintenance procedures performed, including replaced parts required to maintain the equipment in accordance with the specifications. Must provide within fifteen calendar days after award date, but not later than performance of the first servicing of equipment, the Contractor will furnish two (2) copies of its preventive maintenance procedures manuals which will be used during the preventive maintenance services of this contract to the Contracting Officer Representative. The contractor shall perform electrical safety measurements on all equipment under this contract in accordance with manufacturer s specifications. Scheduled Maintenance: Develop and provide a detailed maintenance schedule outlining all preventive maintenance activities to be performed, including recommended intervals. Notify the Pathology and Lab s Contracting Officer Representative at least one week in advance of any scheduled maintenance visits. Emergency Services: Provide emergency maintenance services outside of scheduled maintenance visits as needed. In response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met: NAICS Code: Company Name: Address: UEI (Unique Entity ID) Number: Contact Name: Phone No.: Email: Business Size Information - Select all that applies: Small Business Emerging Small Business Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act HUBZone Woman Owned Certified Service-Disabled Veteran Owned Small Veteran Owned Small Business Large Business FSS/GSA Contract Holder: Yes No FSS/GSA Contract Number:
Effective Date/ Expiration Date:
Proposed solution is listed and available on the above FSS/GSA Contract: Yes No Pricing Model Please Indicate Availability Below: (Yes / No / NA) All on FSS Open Market only Mix of FSS & Open Market Firm-Fixed Price

Federal Acquisition Regulation (FAR) Market Rearch Questions:

Buy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a:

Domestic end product? _____________ (%)

Foreign end product? _______________ (%) Country of Origin:

Questions for Small Businesses ONLY:

If subcontracting, what added value do you offer (RFO 52.215-23):

Nonmanufacturer Rule (RFO 52.219-33): Does your company manufacturer these proposed items? [  ] yes [  ] no Does your company exceed 500 employees? [  ] yes [  ] no If yes, list # of employees: _________ Does your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [  ] yes [  ] no Does your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [  ] yes [  ] no Does your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [  ] yes [  ] no If yes, what is the manufacturer s name? ________________
Response Instructions: Do not provide more than 8 pages, including cover letter page. Submit your response via email to contact@example.gov Submit your response NLT 16:00 (MST) on Friday, June 12, 2026; Mark your response as Proprietary Information if the information is considered business sensitive. VA has identified the appropriate North American Industry Classification System (NAICS) Code as 811210 Electronic and Precision Equipment Repair and Maintenance with a Small Business size of $34 Million. Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List. (End of Sources Sought)

More opportunities from Department Of Veterans Affairs → Network Contract Office 19 (36C259)

Same awarding agency

NAICS: 623220
New
Federal
Q519--554 | Short Term Psychiatric Transitional Housing Long-Term Contract | Base+4
Solicitation # 36C25926Q0497
Solicitation 36C25926Q0497, issued by the Department of Veterans Affairs Network Contracting Office 19, seeks a contractor to provide short-term, transitional residential care and psychiatric step-down services for the Rocky Mountain Regional VA Medical Center in Aurora, Colorado. The scope of work includes the potential use of Mental Health Transitional Living Homes Level I or II. The contract is structured with a base period from December 1, 2026, to November 30, 2027, and four subsequent one-year option periods. Payment is based on an individual bed day of care, defined as the period from 12:00 pm to 11:59 am the following day. The government will award the contract based on the most advantageous offer, evaluating technical capability, regulatory practices including HIPAA and OSHA compliance, and quality assurance programs. Contractors must maintain 24-hour staffing, ensure ADA accessibility, and adhere to strict health and safety codes. Required submissions include three separate volumes covering technical capability, past performance, and price, along with certifications for the Immigration and Nationality Act and Organizational Conflicts of Interest. Performance will be monitored through a Quality Assurance Surveillance Plan involving unannounced site visits, patient satisfaction surveys, and clinical outcome measures.
Residential Mental Health and Substance Abuse Facilities

POSTED

about 16 hours ago

DEADLINE

in 8 days
View Details
NAICS: 339112
New
Federal
6695--SURGERY GLOBUS INSTRUMENT SET
Solicitation # 36C25927Q0043
The Oklahoma City Veterans Affairs Health Care System requires one complete Globus Medical instrument set for use in neurology and orthopedic spine surgeries. This comprehensive solution must include all necessary components for functionality, such as cables, connectors, and mounts, and must adhere to stainless-steel standard operating procedures. The instruments must be reusable and specifically designed for spinal procedures in the operating room. The contractor must be an expert in the neuro and ortho spine field and is responsible for replacing any malfunctioning or broken items at no cost to the VA for the first 12 months following purchase, coordinating maintenance with the OKC VAHCS Biomedical Engineering Department. This procurement is identified as a sources sought notice under NAICS code 339112 and is set aside for Service-Disabled Veteran-Owned Small Businesses. Deliveries to the Oklahoma City facility are required Monday through Friday between 07:00 and 16:00. The instrument set consists of 35 specific line items, including various pedicle probes, rod templates, ratcheting handles, driver shafts, and taps. Interested vendors must provide a capability statement, business size information, country of origin, and estimated lead times. There are no security accreditation requirements as the contractor will have no access to patient records or restricted hospital areas, and no VA employee training is required.
Surgical and Medical Instrument Manufacturing

POSTED

1 day ago

DEADLINE

in 8 days
View Details
NAICS: 513210
New
Federal
R604--Mail Tracking Service
Solicitation # 36C25927Q0017
Solicitation 36C25927Q0017 is a firm-fixed price contract set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) to provide a web-based package and mail tracking system for the Department of Veterans Affairs. The primary site of performance is the Rocky Mountain Regional VA Medical Center in Aurora, Colorado, specifically within the KS-100 SCMS Warehouse. The system must be capable of processing approximately 250,000 parcels and will initially support up to 12 users. The contractor is responsible for providing all necessary hardware, including one barcode printer, 12 scanners with integrated signature pads, and one mobile device, as well as all associated consumables and routine replacement parts. The software will operate as a standalone system not connected to the VA network, meaning it should be SaaS permitted and will not require integration with internal VA identity management or directory services. The contract consists of a base period from October 30, 2026, to October 29, 2027, with four subsequent one-year options extending the total potential duration to five years and six months. Quotes are due by 14:00 MT on October 30, 2026. Pricing must be comprehensive, including all initial hardware, installation, and implementation costs within the original quote, though the government accepts a higher base-year price to account for these non-recurring expenses. Technical support is required to align with warehouse operating hours of 6:30 a.m. to 2:30 p.m. Award will be based on a comparative analysis of technical capability, price, and past performance, with a strict requirement that offerors be VetCert verified to be eligible for award.
Software Publishers

POSTED

3 days ago

DEADLINE

in about 16 hours
View Details
NAICS: 238110
New
Federal
554-27-117 Conduct Concrete and Civil Site Repairs.
Solicitation # 36C25926Q0826
Solicitation 36C25926Q0826 is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) to perform concrete and civil site repairs at the Rocky Mountain Regional VA Medical Center in Aurora, Colorado. The project, estimated between 100,000 and 250,000 dollars, involves comprehensive drainage remediation, sidewalk leveling, curb repair, and the removal and replacement of concrete sections to address trip hazards and improve snow removal. The scope of work includes 52 specific repair items and requires strict adherence to VA standards, AIA Construction Guidelines, and Joint Commission Environment of Care Standards. Performance must begin within 10 calendar days of award and be completed within 90 calendar days. The government will award the contract based on best value, evaluating offerors on price, past performance on at least two similar projects of 100,000 dollars or more within the last five years, and safety records, including an Experience Modification Rate (EMR) of 1.0 or less. Contractors must provide a Site Specific Safety Plan and ensure a competent person with a 30-hour OSHA card is on-site at all times. Proposals must be submitted via email to Elia L Ruiz Manzo by November 13, 2026, at 10:00 AM MT, and must include a signed SF-1442, a Limitations on Subcontracting certification, and past performance documentation.
Poured Concrete Foundation and Structure Contractors

POSTED

3 days ago

DEADLINE

in 15 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS