Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Defense was posted on November 1, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Laboratory Testing Supplies for the Landstuhl Regional Medical Center (LRMC), Germany

Closed
W9114F22Q0094Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 325413
New
DIBBS
CULTURE MEDIUM, THAYER-
Solicitation # SPE2DS-27-T-1066
Solicitation SPE2DS-27-T-1066 is a request for quotations issued by the DLA Troop Support Medical Supply Chain for the procurement of one package of Thayer-Martin Modified (MTM II) Agar culture medium, identified by NSN 6550-01-711-1542. This dark brown, ready-to-use plated medium is specifically designed for the isolation of pathogenic Neisseria from specimens containing mixed flora of bacteria and fungi. The product is delivered in packages of 100 plates and requires strict refrigeration storage between 2 to 8 degrees Celsius (36 to 46 degrees Fahrenheit) and must not be frozen. The contract mandates a non-extendable shelf life of three months, with a requirement that no more than 14 days elapse between the date of manufacture and the date of delivery to the government. Delivery is set for JBER, Alaska, with a required delivery date of October 27, 2026, under FOB Destination terms. Packaging must be commercial and sealed to prevent damage, with marking adhering to Medical Marking Standard No. 1 and shelf-life labels following MMS1C. Administrative requirements include electronic invoicing via the Wide Area WorkFlow system and compliance with various FAR and DFARS clauses, including the Buy American Act, Berry Amendment, and safeguarding of covered defense information. Evaluation will consider technical data for any alternate products offered and may include HUBZone price evaluation preferences. Inspection and acceptance will occur at the destination.
MEDICAL SUPPLY CHAIN MD SURG FSF

POSTED

2 days ago

DEADLINE

in 4 days
NAICS: 325413
New
Federal
6550--Optilite analyzer reagents
Solicitation # 36C26227Q0052
The Department of Veterans Affairs, Southern Arizona Healthcare System, is soliciting a Firm-Fixed Price Blanket Purchase Agreement under solicitation 36C26227Q0052 for the procurement of FDA-approved reference testing reagents and consumables validated for use on the Optilite analyzer. The scope includes specific items such as Freelite Kappa, Freelite Lambda, and Ceruloplasmin reagents, as well as TENCELL cuvettes and sample cups. To ensure system performance and safety, all materials must be manufactured by Binding Site Laboratories, and substitutions are prohibited. The contract is issued as a full and open competition under NAICS code 325413, with a total estimated period of performance of sixty months, consisting of a base period from November 9, 2026, to November 8, 2027, followed by four one-year option periods. The award will be granted to the responsible offeror whose proposal is most advantageous to the government, based on a technical acceptability review of the Statement of Work and the lowest price. Deliveries are required to be made to various VA Medical Centers across Arizona, California, and New Mexico, with standard orders delivered within four working days of placement. All shipments must be destination-based, with the vendor assuming all shipping costs and adhering to strict packaging standards to prevent damage. Invoicing is handled electronically through the Department of Veterans Affairs Financial Services Center in accordance with the Prompt Payment Act. Quotes must be submitted via email to Contract Specialist Carlos Magana by November 4, 2026.
262-NETWORK Contract Office 22 (36C262)

POSTED

3 days ago

DEADLINE

in 5 days
NAICS: 325413
Federal
BPA - Consumable Supplies for Terumo Trima Accel Blood Collection systems
Solicitation # HT942627QE003
The Defense Health Agency is soliciting quotations to establish a Blanket Purchase Agreement (BPA) for the recurring resupply of consumable products for three Terumo Trima Accel Blood Collection Systems used by the USAISR Combat Casualty Care Research Team 1 in Texas. To maintain FDA approval and satisfy research protocols, the contractor must provide original manufacturer-supplied consumables, including Teruflex 500ml collection bags, Trima Platelet Kits, Isoplate Solution (PAS-F), TSCD Wafers, ACD-A Solution, and 150 mL couplers. This procurement is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 325413. The resulting BPA will have a 60-month ordering period with a total ceiling of 35 million dollars, though some documentation notes a lower limit of 350,000 dollars. Individual call orders are capped at 50,000 dollars, while Government Purchase Card orders are limited to 15,000 dollars. Awards will be made on a Lowest Price Technically Acceptable basis, with technical capability rated as pass or fail. All payment requests and receiving reports must be processed electronically through the Wide Area WorkFlow system. Quotations are due by November 6, 2026, and must be submitted in two separate volumes covering technical capability and pricing.
Army Medical Resources Acq Activity

POSTED

7 days ago

DEADLINE

in 7 days
NAICS: 325413
Federal
6550--VISN Cepheid GeneXpert Testing Supplies Base Plus 3 Op Yr RFQ
Solicitation # 36C24527Q0042
The Department of Veterans Affairs, specifically the VA North Atlantic Health Network (HSA 1.3), is soliciting a firm-fixed-price, Indefinite Delivery/Indefinite Quantity (IDIQ) contract for Cepheid GeneXpert testing supplies. This requirement covers the procurement of FDA-approved reagents, consumables, and service for PCR analyzers to detect various pathogens, including CoV-2, Influenza, RSV, MRSA, and Mycobacterium Tuberculosis. The contract is structured with a base period ending October 31, 2027, and three subsequent one-year option periods extending through October 31, 2030. Deliveries will be made to multiple VA Medical Centers across Maryland, West Virginia, and Washington DC. This acquisition is set aside for HUBZone small businesses. Award will be determined using the Lowest Price Technically Acceptable (LPTA) method, evaluating technical acceptability, delivery performance, past performance, and price, with additional credit given to certified SDVOSB or VOSB offerors. Key contractor requirements include being an authorized distributor, acknowledging orders within 24 hours, and guaranteeing a minimum four-month expiration date on reagents. Additionally, the vendor must provide an emergency plan to deliver replacement supplies within 24 hours if products are found to be defective. Invoices must be submitted electronically, and payments will be processed in accordance with the Prompt Payment Act.
245-NETWORK Contract Office 5 (36C245)

POSTED

8 days ago

DEADLINE

in 6 days

General Info

NAICS

325413 - In-Vitro Diagnostic Substance Manufacturing

Place of Performance

AE, DEU

Set-Aside

NONE

Documents

3

W9114F22Q0094-0001_RFQ_Conformed.pdf

PDF

W9114F22Q0094_Amendment+0001.pdf

PDF

W9114F22Q0094_RFQ.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Notice updated

Response deadline changed from Nov 1, 2022 to Nov 4, 2022. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W40M Mrco Europe
Contacts2 people available
OfficeAPO, AE, 09180-0402, USA
Office AddressAPO, AE, 09180-0402, USA
Contacts
Henning Mayer-Goldstein
Matthew R. Elden

Full Description

Show more
The Regional Health Contracting Office-Europe issued a solicitation for delivery of Laboratory Testing Supplies for the Landstuhl Regional Medical Center (LRMC), Germany. The resultant contract type will be a Firm-Fixed-Price (FFP) Purchase Order. It is incumbent upon interested parties to review this site frequently for any updates/amendments to any and all documents. The solicitation will be issued for full and open competition. All vendors must be registered in the System for Award Management (SAM) prior to award, and lack of registration shall make a quotation ineligible for award. Vendors may obtain information on registration and annual confirmation requirements by calling +1 (555) 000-0000 or via Internet at https://www.sam.gov. QUOTE SUBMISSION 1. INSTRUCTION ELECTRONIC Quote. Quoters may submit electronic quote in response to this Request for Quote. The quote must be received by the quote due date/local time as specified in block 8 of the SF 1449 cover page to the inbox of the following email address: contact@example.gov Vendors may call Mr. Henning Mayer-Goldstein at +49 (6371) 9464 6789 to verify receipt of the quote. If the vendor chooses to email the quote, the Government will not be responsible for any failure of transmission or receipt of the quote, or any failure of the vendor to verify receipt of the emailed quote. FORMAT and SIZE: Each paragraph shall be separated by at least one blank line. A standard, 12-point minimum font size applies. Margins: Top, Bottom, Left, Right - 1 Page Size, Width - 8.5 Page Size, Height - 11 or DIN A4 size. Tables and illustrations may use a reduced font size not less than 8-point and may be landscape. Page size 11x17 or DIN A3 size may be used where needed for readability, however, each printed side of an 11x17 or A3 size page will count as two pages. Page limitations shall be treated as maximums. If exceeded, the excess pages will not be read or considered in the evaluation of the quote and (for paper copies) will be returned to the quoter as soon as practical. The technical quote shall address how you will comply with the requirements set forth in the line item description and must clearly explain each of the technical subfactors (see paragraph 52.212-2 for details). The following is excluded from the page count: copies of certificates, price schedule, completed FAR 52.212-3 Quoter Representations and Certifications - Commercial Items, and acknowledgement of any amendments issued. Page Limitations. Page limitations shall be treated as maximums. Pages in excess of the below limitations will be removed and disregarded during the evaluation. When both sides of a sheet display printed material, it shall be counted as two pages. Each page shall be counted except the following: covers, tab dividers, title pages, glossaries, and table of contents/file index. Also, page limits are applicable to legible tables, charts, graphs and figures used wherever practical to depict organizations, implementation schedules, plans, etc. The quote shall consist of the following sections and be limited by the maximum page limit. Section # Section Title Maximum Page Limit per Section Section 1 Factor 1 - Technical 20 pages Section 2 Factor 2 - Prices on SF 1449 2 pages, if required (completed and signed) (in addition to the SF 1449) QUESTIONS. Prospective quoters are strongly encouraged to submit any questions regarding this Request for Quote no later than three (3) business days prior to the request for quote due date specified in block 8 of the SF 1449 cover page. Questions can be emailed to contact@example.gov. All questions received will be answered officially through an amendment to the Request for Quote for distribution to all prospective quoters. Questions received after the CET cut-off date/time will not be accepted by the Government. 52.229-11, Tax on Certain Foreign Procurements - Notice and Representation. Ensure you provide the completed provision and have read the clause at FAR 52.229-12, Tax on Certain Foreign Procurements. FACTOR 1 - TECHNICAL: The quoter shall submit a written quote which explains how to comply with the requirements in the request for quote: SUBFACTOR 1: Testing supplies shall meet all salient characteristics. The quoter shall state whether the brand name or an equal product is quoted. If an equal product is quoted, the quoter shall provide the full name of the offered testing supplies along with item number, manufacturer's name and all salient characteristics. SUBFACTOR 2: Testing supplies shall be compatible for use with the Hologic Panther Analyzer. If the an equal product is quoted, proof of compatibility with the Hologic Panther Analyzer shall be provided. Salient Characteristics for CT/GC Testing Supplies Reagents must be compatible for use with the Hologic Panther Analyzer. Reagents must be capable of in vitro qualitative detection and differentiation of ribosomal RNA (rRNA) from Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (GC) to aid in the diagnosis of chlamydial and gonococcal disease using the Hologic Panther System. Reagents must be authorized by FDA under at least an Emergency Use Authorization (EUA) for use, capable of producing extracted nucleic acid in accordance with College of American Pathologist (CAP) and CLIP/CLIA/CLSI guidelines. Reagents must be a target amplification nucleic acid probe test. All reagents provided shall be identical to those used in the FDA 510K approval application. If the bulk reagents are produced overseas, they shall be manufactured in conformance with ISO or CE standards AND must be equal to or better than the U.S. products in quality/manufacturing. All reagents must be functional through the life of the reagent (e.g. expiration date). All non-functional reagents (e.g. failed runs), where non-functionality cannot be attributed to technician error, must be replaced by the Contractor. Reagents must be received at the required temperature indicated on the product insert and have a shelf life of at least six (6) months upon receipt at the Receiving Activity (consignee), or as stated within the individual line item (i.e. Delivery Ticket, Invoice). Additional supplies that should included at no additional cost to complete each test include: Combo 2 Controls Kit (pos/neg), Multi-Tube Unit Kits, Waste Bag, Waste Cover, Universal Fluids Kit, Advanced Cleaning Solution (255mL), and Spare Caps. Salient Characteristics for SARS-CoV-2 Testing Supplies Reagents must be compatible for use with the Hologic Panther Analyzer. Reagents must be capable of conducting nucleic acid extraction of RNA from SARS-CoV-2 isolated and purified from nasopharyngeal, oropharyngeal swab specimens, nasopharyngeal washes/aspirates or nasal aspirates, anterior nasal and mid-turbinate nasal swab from individuals who meet COVID-19 clinical and epidemiological criteria in accordance with CDC guidelines. Reagents must be authorized by FDA under at least an Emergency Use Authorization (EUA) for use, capable of producing extracted nucleic acid in accordance with College of American Pathologist (CAP) and CLIP/CLIA/CLSI guidelines. All reagent kits must include amplification, enzyme, probe reagent and Internal Control. All reagents provided shall be identical to those used in the FDA 510K approval application. If the bulk reagents are produced overseas, they shall be manufactured in conformance with ISO or CE standards AND must be equal to or better than the U.S. products in quality/manufacturing. All reagents must be functional through the life of the reagent (e.g. expiration date). All non-functional reagents (e.g. failed runs), where non-functionality cannot be attributed to technician error, must be replaced by the Contractor. Reagents must be received at the required temperature indicated on the product insert and have a shelf life of at least six (6) months upon receipt at the Receiving Activity (consignee), or as stated within the individual line item (i.e. Delivery Ticket, Invoice). Additional supplies that should included at no additional cost to complete each test include: SARS-CoV-2 Assay Controls (pos/neg), Multi-Tube Unit Kits, Waste Bag, Waste Cover, Universal Fluids Kit, Advanced Cleaning Solution (255mL). Salient Characteristics for Tips Tips [liquid hanging (LiHa), 1000 microliter, filtered, conductive and disposable], must be compatible for use with the Hologic Panther Analyzer. Salient Characteristics for Mycoplasma Testing Supplies Reagents must be compatible for use with the Hologic Panther Analyzer. Reagents must be capable of in vitro nucleic acid amplification test (NAAT) for the qualitative detection of ribosomal RNA (rRNA) from Mycoplasma genitalium. Reagents must be intended for use as an aid in the diagnosis of M. genitalium urogenital infections in male and female patients suspected of M. genitalium infection using the Hologic Panther System Reagents must be authorized by FDA under at least an Emergency Use Authorization (EUA) for use, capable of producing extracted nucleic acid in accordance with College of American Pathologist (CAP) and CLIP/CLIA/CLSI guidelines. Reagents must be a target amplification nucleic acid probe test. All reagents shall be identical to those used in the FDA 510K approval application. If the bulk reagents are produced overseas, they shall be manufactured in conformance with ISO or CE standards AND must be equal to or better than the U.S. products in quality/manufacturing. All reagents must be functional through the life of the reagent (e.g. expiration date). All non-functional reagents (e.g. failed runs), where non-functionality cannot be attributed to technician error, must be replaced by the Contractor. Reagents must be received at the required temperature indicated on the product insert and have a shelf life of at least six (6) months upon receipt at the Receiving Activity (consignee), or as stated within the individual line item (i.e. Delivery Ticket, Invoice). Additional supplies that should be included at no additional cost to complete each test include: Mycoplasma genitalium Controls Kit (pos/neg), Multi-Tube Unit Kits, Waste Bag, Waste Cover, Universal Fluids Kit, and Advanced Cleaning Solution (255mL). Salient Characteristics for BV Testing Supplies Reagents must be compatible for use with the Hologic Panther Analyzer. Reagents must be capable of in vitro nucleic acid amplification test that utilizes real time transcription-mediated amplification (TMA) for detection and quantitation of ribosomal RNA from bacteria associated with bacterial vaginosis (BV), including Lactobacillus (L. gasseri, L. crispatus, and L. jensenii), Gardnerella vaginalis, and Atopobium vaginae using the Hologic Panther System.. Reagents must be authorized by FDA under at least an Emergency Use Authorization (EUA) for use, capable of producing extracted nucleic acid in accordance with College of American Pathologist (CAP) and CLIP/CLIA/CLSI guidelines. Reagents must be a target amplification nucleic acid probe test. All reagents shall be identical to those used in the FDA 510K approval application. If the bulk reagents are produced overseas, they shall be manufactured in conformance with ISO or CE standards AND must be equal to or better than the U.S. products in quality/manufacturing. All reagents must be functional through the life of the reagent (e.g. expiration date). All non-functional reagents (e.g. failed runs), where non-functionality cannot be attributed to technician error, must be replaced by the Contractor. Reagents must be received at the required temperature indicated on the product insert and have a shelf life of at least six (6) months upon receipt at the Receiving Activity (consignee), or as stated within the individual line item (i.e. Delivery Ticket, Invoice). Additional supplies that should be included at no additional cost to complete each test include: BV Controls Kit (pos/neg), Multi-Tube Unit Kits, Waste Bag, Waste Cover, Universal Fluids Kit, and Advanced Cleaning Solution (255mL). Salient Characteristics for CV/TV Testing Supplies Reagents must be compatible for use with the Hologic Panther Analyzer. Reagents must be capable of in vitro nucleic acid amplification test for the detection of RNA from microorganisms associated with vulvovaginal candidiasis and trichomoniasis using the Hologic Panther System. Reagents must be authorized by FDA under at least an Emergency Use Authorization (EUA) for use, capable of producing extracted nucleic acid in accordance with College of American Pathologist (CAP) and CLIP/CLIA/CLSI guidelines. Reagents must be a target amplification nucleic acid probe test. All reagents shall be identical to those used in the FDA 510K approval application. If the bulk reagents are produced overseas, they shall be manufactured in conformance with ISO or CE standards AND must be equal to or better than the U.S. products in quality/manufacturing. All reagents must be functional through the life of the reagent (e.g. expiration date). All non-functional reagents (e.g. failed runs), where non-functionality cannot be attributed to technician error, must be replaced by the Contractor. Reagents must be received at the required temperature indicated on the product insert and have a shelf life of at least six (6) months upon receipt at the Receiving Activity (consignee), or as stated within the individual line item (i.e. Delivery Ticket, Invoice). Additional supplies that should be included at no additional cost to complete each test include: CV/TV Controls Kit (pos/neg), Multi-Tube Unit Kits, Waste Bag, Waste Cover, Universal Fluids Kit, and Advanced Cleaning Solution (255mL). Salient Characteristics for HPV Testing Supplies Reagents must be compatible for use with the Hologic Panther Analyzer. Reagents must be capable of in vitro nucleic acid amplification test for the qualitative detection of E6/E7 viral messenger RNA (mRNA) from 14 high-risk types of human papillomavirus (HPV) in cervical specimens. The high-risk HPV types detected by the assay include: 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, and 68. The HPV assay does not discriminate between the 14 high-risk types. Cervical specimens in ThinPrep PapTest vials containing PreservCyt Solution and collected with broom-type or cytobrush/spatula collection devices may be tested with the HPV assay. The assay is used with the Hologic Panther System. Reagents must be authorized by FDA under at least an Emergency Use Authorization (EUA) for use, capable of producing extracted nucleic acid in accordance with College of American Pathologist (CAP) and CLIP/CLIA/CLSI guidelines. Reagents must be a target amplification nucleic acid probe test. All reagents shall be identical to those used in the FDA 510K approval application. If the bulk reagents are produced overseas, they shall be manufactured in conformance with ISO or CE standards AND must be equal to or better than the U.S. products in quality/manufacturing. All reagents must be functional through the life of the reagent (e.g. expiration date). All non-functional reagents (e.g. failed runs), where non-functionality cannot be attributed to technician error, must be replaced by the Contractor. Reagents must be received at the required temperature indicated on the product insert and have a shelf life of at least six (6) months upon receipt at the Receiving Activity (consignee), or as stated within the individual line item (i.e. Delivery Ticket, Invoice). Additional supplies that should be included at no additional cost to complete each test include: HPV Controls Kit (pos/neg), Multi-Tube Unit Kits, Waste Bag, Waste Cover, Universal Fluids Kit, and Advanced Cleaning Solution (255mL). Salient Characteristics for HPV 16 18/45 Testing Supplies Reagents must be compatible for use with the Hologic Panther Analyzer. Reagents must be capable of in vitro nucleic acid amplification test for the qualitative detection of E6/E7 viral messenger RNA (mRNA) of human papillomavirus (HPV) types 16, 18, and 45 in cervical specimens from women with HPV assay positive results. The HPV 16 18/45 genotype assay can differentiate HPV 16 from HPV 18 and HPV45, but does not differentiate between HPV 18 and HPV 45. Cervical specimens in ThinPrepPap Test vials containing PreservCyt Solution and collected with broom-type or cytobrush/spatula collection devices may be tested with the HPV 16 18/45 genotype assay. The assay is used with the using the Hologic Panther System. Reagents must be authorized by FDA under at least an Emergency Use Authorization (EUA) for use, capable of producing extracted nucleic acid in accordance with College of American Pathologist (CAP) and CLIP/CLIA/CLSI guidelines. Reagents must be a target amplification nucleic acid probe test. All reagents shall be identical to those used in the FDA 510K approval application. If the bulk reagents are produced overseas, they shall be manufactured in conformance with ISO or CE standards AND must be equal to or better than the U.S. products in quality/manufacturing. All reagents must be functional through the life of the reagent (e.g. expiration date). All non-functional reagents (e.g. failed runs), where non-functionality cannot be attributed to technician error, must be replaced by the Contractor. Reagents must be received at the required temperature indicated on the product insert and have a shelf life of at least six (6) months upon receipt at the Receiving Activity (consignee), or as stated within the individual line item (i.e. Delivery Ticket, Invoice). Additional supplies that should be included at no additional cost to complete each test include: HPV 16 18/45 Controls Kit (pos/neg), Multi-Tube Unit Kits, Waste Bag, Waste Cover, Universal Fluids Kit, and Advanced Cleaning Solution (255mL). (End of Salient Characteristics) FACTOR 2 - PRICE: The quoter shall ensure to provide the quoted prices on the SF 1449 and be in compliance with the following: (1) The quoter shall provide a unit price and extended amount (i.e., quantity multiplied by unit price) shall be submitted for each Contract Line Item Number (CLIN). In case of in case of a discrepancy, the unit price will take precedence. (2) The quoter shall limit their prices to two decimal places (example: $/3.45). ACQUISITION PROCEDURE This is a commercial item under FAR Part 12 and the acquisition procedures to be used for this purchase will be in accordance with FAR Part 13.5, Simplified Procedures for Certain Commercial Products and Commercial Services. SPECIAL NOTE: Offerors and quoters are required to be registered in the System for Award Management (SAM) at the time an offer or quote is submitted and lack of registration will make an offer or quote ineligible for award. Vendors may obtain information on registration and annual confirmation requirements by calling +1 (555) 000-0000 or via Internet at https://www.sam.gov. Questions & Answers: Question 1: The Government received a question regarding line item CLIN 0007, 1007 and 2007 entitled - HPV Testing Supplies in particular to the example item provided as - 303570 Aptima HPV assay (250-T). The part number 303570 is for - Aptima HPV Assay 100 Tests, but the item description is - Aptima HPV assay (250-T) which is for 250 tests per kit. If the test kit for 250 tests is requested, then part number 303093 would be correct. Please advise which packing size is requested. Answer 1: The Government prefers the test kits with the packing size of 250 but can also utilize the packing size of 100 as long as they are sufficient for a total amount of 3,750 tests. Question 2: The Aptima SARS-CoV-2 Control has a price however this item is included in CLIN 0002 at no charge. How would you like us to list that this item has a price and where would you like us to include this cost? Answer 2: The Government prefers to keep the cost of the SARS-CoV-2 Control within the same line item. Question 3: The tips requested in CLIN 0003 are packaged in a case of 9600. If this is the case, do you still need 100 cases (ea) of 9600 tips? Please let us know the total volume requested and how we can convert to provide an accurate total amount. Answer 3: The Government requires a total quantity of 96,000 tips. It is preferred to receive the signed conformed SF1449 document. Alternatively the original SF1449 can be submitted along with the Amendments (SF30s) if all documents are signed.

More opportunities from Department Of Defense → W40M Mrco Europe

Same awarding agency

NAICS: 325413
Federal
Blood Chemistry Testing - Cost Per Reportable Result
Solicitation # W9114F-26-Q-A009
The Medical Readiness Contracting Office-Europe is soliciting a Fixed-Price Indefinite Delivery/Indefinite Quantity contract for one automated chemistry analyzer and associated consumables to support the laboratory mission at the U.S. Army Health Clinic in Vicenza, Italy. Under a Cost Per Reportable Result pricing structure, the successful offeror will provide all new equipment, reagents, consumables, controls, and necessary maintenance. The contract includes a two-month phase-in period from January 2, 2026, to February 28, 2026, followed by an ordering period from March 1, 2026, through December 31, 2030. The estimated annual clinical chemistry workload is 42,595 tests. Technical requirements specify that the analyzer must be FDA-approved, capable of measuring analytes from a 300-microliter sample, and equipped with an uninterruptible power supply providing seven minutes of power. The system must have a current Authorization to Operate for interfacing with the Laboratory Information System and comply with the Risk Management Framework for DOD IT. The contractor is responsible for providing initial on-site operator training in English and ensuring all reagents are delivered at the proper storage temperature. Award will be based on the Lowest Price Technically Acceptable evaluation process under Simplified Acquisition Procedures, with the solicitation open for full competition under NAICS code 325413.
In-Vitro Diagnostic Substance Manufacturing

POSTED

12 months ago

DEADLINE

N/A
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS