This Sources Sought opportunity from Department Of Defense was posted on February 26, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
Lithium Battery Abusive Testing Capabilities
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
General Info
Place of Performance
Crane, OR, USASet-Aside
Documents
0AI Contract Breakdown
Uniform Contract FormatNo documents to break down
The breakdown needs solicitation documents. None were found from this contract's source.
Timeline
Submission Closed
Organization & Contact Information
Full Description
PURPOSE
This special notice is to inform vendors of a Request for Information (RFI). Lithium batteries are a critical power source for a wide range of military applications. To ensure the safety and reliability of these batteries in demanding operational environments, the Department of War (DoW) requires robust testing capabilities to evaluate their performance under abusive conditions. This includes, but is not limited to, thermal, mechanical, and electrical abuse. The DoW is seeking information from industry on the capabilities available for the abusive testing of lithium batteries. Capabilities of interest include cell, module, and battery propagation testing (full casualty), heat release rate testing, gas analysis, and environmental testing. Based off the information collected from the RFI, the Government may send out a Request for Solutions (RFS) with the intent of awarding a Project Order under the Expeditionary Missions Consortium (EMC2) Other Transaction Agreement (OTA) in accordance with 10 U.S.C. § 4022.
BACKGROUND AND SUMMARY
Introduction
The Department of War (DoW) is seeking information from industry on the capabilities available for the abusive testing of lithium batteries. This RFI is intended to gather information on the current state of the market and to identify potential sources for conducting such testing. This is for information and planning purposes only and does not constitute a solicitation for proposals.
Background
Lithium batteries are a critical power source for a wide range of military applications. To ensure the safety and reliability of these batteries in demanding operational environments, the DoW requires robust testing capabilities to evaluate their performance under abusive conditions. This includes, but is not limited to, thermal, mechanical, and electrical abuse.
Information Requested
Interested parties are requested to provide information on their capabilities in the following areas:
Topics to be Addressed within RFI Response
- Testing Environment:
Please describe your testing facilities and indicate whether your capabilities are for indoor or outdoor testing environments.
- Testing Services:
Please provide details on your capability to perform the following types of abusive testing:
- Short Circuit
- Overcharge
- Overdischarge / Voltage Reversal
- High-Temperature
- Battery Management System
- Electrical Safety Device
- Propagation (cell-to-cell within module, module-to-module within battery)
- Crush
- Nail Penetration
- Bullet Penetration
- Environmental (temperature, humidity, altitude, vibration, shock, acceleration)
- Non-Abusive Testing (long-term life-cycle testing, etc)
- Test Capacity:
Describe your capacities for thermal, mechanical, and electrical abuse testing. Specify the maximum voltage that can be tested. Specify the maximum battery size (e.g., dimensions, weight, capacity in kWh) that your facility can accommodate for these tests.
- Heat Release Rate Testing:
Describe your methodology and the equipment used to measure the heat release rate of lithium batteries during thermal runaway events.
Specify the maximum battery size for which you can perform heat release rate testing and the maximum heat energy (MW) that can be measured.
- Gas Analysis:
Detail your capabilities for analyzing the composition of gases released during battery failure, including the identification and quantification of flammable and toxic gases, generation rate, and total amount generated. Specify the maximum battery size that can be tested with your gas analysis equipment.
- Business Information:
Please provide the following information about your organization:
- Testing Standards: (Navy S9310, UN 38.3, UL, SAE, IEEE, ISO, etc)
- Willingness to Collaborate: State your company's willingness to work with the DoW.
- Business Structure: Indicate whether your company is an independent testing facility or part of a larger battery vendor or manufacturer. Note any potential concerns working with proprietary data.
- Testing Constraints: Are there any constraints to the type or amount of testing that can be performed at your facility? (location, environmental permit restrictions, etc)
Format Requirements of the RFI Papers
-
- 10-page limit, inclusive of contact information.
- Times New Roman 10 (or larger) Single-spaced, single-sided, 21.6 x 27.9 cm (8.5 by 11 inches).
- Smaller type may be used in figures and tables, but must be clearly legible.
- No pictures of a marketing/advertising nature or hyperlinks are allowed.
- File format must be Microsoft Word or PDF.
- These RFI submissions will be shared with the Sponsor; therefore, all information must be non-proprietary.[CM1]
- Do not submit classified information.
Eligibility
Any industry member is authorized to submit a solution for the listed RFI above. However, to be eligible to respond to any future RFS, respondents must be a member of the EMC² Consortium and be a ‘Member in Good Standing’.
All interested parties should visit the EMC2 website at https://emccrane.org/ to become a member of the consortium to view the future possible RFS.
More opportunities from Department Of Defense → Nswc Crane
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS