Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Health And Human Services was posted on July 29, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

LSM990 Confocal Airyscan2 System

Closed
75N98026Q00888Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334516
New
Federal
Temp Controlled 42 Plate Hotel
Solicitation # AB482902
Brookhaven Science Associates (BSA) is soliciting quotations for the procurement of a temperature-controlled plate storage incubator with two stackers and a built-in barcode reader, along with comprehensive on-site installation and training for integration with the Art Robbins CryCam UV imaging system at Brookhaven National Laboratory (BNL). The system must support SBS/ANSI-SLAS, low-profile SBS, and Linbro plates, maintaining temperatures between 4C and 25C. This is a small business set-aside solicitation for a firm fixed price purchase order, with the award based on the lowest total evaluated price from a responsive and responsible offeror. Quotations are due by October 2, 2026, and must remain valid for at least sixty days. The procurement includes strict shipping and pricing requirements. For items under 150lbs, shipping may occur via BSA's FedEx account; otherwise, pricing must be all-inclusive of freight, tariffs, and handling. For foreign products over 150lbs where all-inclusive pricing is unavailable, BNL will act as the Importer of Record under DAP Incoterms. Suppliers must provide the country of origin, Unique Entity Identifier (UEI), and applicable ECCN and HTS codes. All electrical equipment must be certified by a Nationally Recognized Testing Laboratory, and onsite personnel must adhere to stringent security badging and safety protocols, including specific documentation requirements for non-U.S. citizens. The contract incorporates BSA General and Supplemental Terms and Conditions for non-commercial items and onsite work, as well as various FAR clauses.
Brookhaven National Labor -Doe Contractor

POSTED

about 18 hours ago

DEADLINE

in 21 days
NAICS: 334516
New
Federal
Flash Point Tester (FA465926QZ008)
Solicitation # FA465926QZ008
The 319 Contracting Squadron is soliciting quotes for the procurement of one automated Pensky-Martens closed-cup flash point tester for the 319 LRS/LGRF at Grand Forks Air Force Base, North Dakota. This requirement is a total small business set-aside under NAICS code 334516. The equipment must be a new production model from 2025 or newer, compatible with 100-120V and 220-240V power supplies, and compliant with ASTM D93, ISO 2719, and IP 34 standards. The purchase must include a complete test set consisting of a test cup, lid with integrated stirrer, multi-detector sensor, holder set with drip pans, and certified reference material for fuel. Additionally, the vendor must provide a minimum three-year manufacturer warranty and two on-site preventive maintenance visits by a certified service engineer. Quotes are due by September 16, 2026, with a required delivery date of November 30, 2026, shipped FOB Destination. The government will award the contract based on a best-value decision, evaluating technical offers on a pass/fail basis against salient characteristics and conducting a price analysis to ensure reasonableness. Eligible offerors must be actively registered in the System for Award Management and enrolled in Wide Area Workflow, which is the only acceptable means for invoicing. Submissions must be limited to 10 pages and include a completed quote schedule, CAGE code, and DUNS number.
FA4659 319 Cons Pk

POSTED

about 18 hours ago

DEADLINE

in 5 days

AI Contract Overview

Show more

The National Institute on Deafness and Other Communication Disorders at the National Institutes of Health intends to award a sole-source, firm-fixed-price purchase order to Carl Zeiss Microscopy for the procurement of a LSM 990 microscope equipped with the Airyscan-2 detector. This system is critical for high-resolution imaging of mouse inner ear tissues and live zebrafish cellular structures, offering superior spatial resolution and sensitivity compared to the current aging LSM780 system, which is no longer supported with service contracts or replacement parts. The Airyscan-2 technology is proprietary to Zeiss and essential for achieving publication-quality data, enabling high-resolution imaging at lower laser power to reduce photobleaching and phototoxicity during extended live experiments. The LSM 990 is also compatible with the existing ZEN software platform, ensuring seamless integration and faster processing of datasets, which will significantly improve throughput and efficiency for multiple NIDCD laboratories. The contract requires delivery, installation, re-alignment, and recalibration of the system at the specified location in Bethesda, Maryland, with the quoted price covering all costs including shipping, installation, training, and warranty. Offerors must submit their quotations electronically to Tina Robinson by August 6, 2026, before 9:00 AM Eastern Daylight Time, and must maintain an active System for Award Management registration throughout the contract lifecycle to be eligible for award. The solicitation follows FAR Part 12 and 13.5 guidelines and includes applicable federal and HHS clauses covering prompt payment, electronic submissions, anti-lobbying, and equal employment opportunity compliance. No set-aside provisions apply, and only the specified Zeiss system meets the technical requirements due to its unique Airyscan-2 capabilities.

General Info

NIDCD awards Zeiss sole-source contract for LSM 990 with Airyscan-2 for high-resolution live tissue imaging in Bethesda.

Agency

Department Of Health And Human Services → National Institutes Of Health NichdView Agency

NAICS

334516 - Analytical Laboratory Instrument ManufacturingView NAICS

Place of Performance

Bethesda, MD, 20892, USA

Set-Aside

NONE

Documents

(2)

Updated+RFQ+75N98026Q00888+Items+List.pdf.pdf

PDF

RFQ 75N98026Q00888 Items List

PDFrfq

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

2 updates
PhaseClosed
Posted

Combined Synopsis

Amendment 1

Contract was updated

Amendment 2

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Health And Human Services → National Institutes Of Health Nichd
Contacts1 person available
OfficeBETHESDA, MD, 20817, USA
Organization / Agency
Department Of Health And Human Services → National Institutes Of Health Nichd
View Agency Profile
Office AddressBETHESDA, MD, 20817, USA
Contacts

Full Description

Show more

This notice is to update FAR clauses and the attachment. There are no other changes to this notice.


1 GENERAL INFORMATION


This is a combined synopsis/solicitation for commercial products prepared in accordance with the Far Part 12 as supplemented with additional information included in this notice, and in conjunction with  Far subpart 13.5 and Far 8.402(f). This announcement constitutes the only solicitation; quotations are being requested, and a separate written solicitation will not be issued.
The National Institutes of Health (NIH), National Institute on Deafness and Other Communication Disorders (NIDCD), Intends to contract on a sole source basis with Carl Zeiss Microscopy – One North Broadway, White Plains, NY 10601 to procure a LSM 990 w/Airyscan-2 Microscope consisting of all the items per the attachment provided in this notice.
The Government intends to award a Firm-Fixed-Price Purchase Order resulting from this solicitation.


2. DESCRIPTION OF REQUIREMENT


2.1 Background The NIDCD relies on high-resolution microscopy to image mouse inner ear tissues and to perform live imaging of cellular organelle development and function in zebrafish. The LSM990, equipped with the proprietary Airyscan 2 detector, provides the spatial resolution and sensitivity required to visualize subcellular structures that cannot be adequately resolved with conventional confocal microscopy. The 32-channel GaAsP detector array achieves resolution of approximately 90 nm in the lateral dimension and 200 nm in the axial dimension while simultaneously improving signal collection efficiency. The enhanced sensitivity of the Airyscan 2 detector allows imaging at lower laser powers, reducing photobleaching and phototoxicity during long-term live imaging experiments. This combination of high resolution and gentle imaging is essential for studying dynamic cellular processes in living tissues. In addition, the LSM990 offers substantial improvements in data handling compared with the older LSM780, generating raw datasets that are approximately eight-fold smaller and enabling
Airyscan image processing that is up to five-fold faster. These advances improve both experimental throughput and data management for high-resolution live imaging studies. The Zeiss LSM 990 with Airyscan 2 enables gentle, high-sensitivity imaging of both live and fixed samples, including fine structures in the mouse inner ear and zebrafish lateral line. The Airyscan 2 detector array improves signal detection and spatial resolution while allowing imaging at low laser power, thereby minimizing photobleaching and phototoxicity. The Labs’ current Zeiss LSM780 confocal system is heavily used by researchers from three NIDCD laboratories and is no longer covered by a service contract, with many replacement parts no longer available. Zeiss ZEN software is user-friendly and intuitive, allowing new users to become proficient quickly. Because the LSM990 operates on the latest version of the same software platform, it will provide a seamless transition while ensuring reliable, faster, higher-quality, and more efficient image acquisition for the many NIDCD investigators who depend on this system. Overall, the Zeiss LSM 990 will provide essential imaging capabilities and meet current and future microscopy needs at NIDCD.
Brand Name Only: Sole Source Authority -  13.501 for Open Market and 8.405-6 for GSA items
The Airyscan detector of LSM990 system represents a proprietary technology from Carl Zeiss Microscopy, LLC and a continuation of Airyscan detector use in the lab is essential to generate high-resolution publication quality data and efficiently complete the research projects that are ongoing in the lab using this detector, only Zeiss LSM990 system would suffice the goal.
3. DELIVERY / PLACE OF PERFORMANCE Delivery, installation, re-alignment and recalibration once the microscope systems have been added to its permanent location in the lab.
National Institutes of Health 9000 Rockville Pike Building 35A, Room 1D-9333 Bethesda, MD 20892
4. Price Quote The price quote shall include: • unit price, • extended price, • total quoted price, • any shipping charges, • any installation/startup/training charges, • warranty information,
• any other separately priced items. The total quoted price shall include all costs necessary to provide a complete and fully functional system meeting the requirements of this solicitation.


5. SAM Registration In order to receive an award, offerors must maintain an active SAM registration for all awards throughout the entire contract/order lifecycle, from offer submission to final payment. Failure to maintain an active SAM registration can jeopardize the award or result in non-payment. Lack of valid registration in SAM will make an offerors/contractor ineligible for award.


6. SUBMISSION INSTRUCTIONS Quotations shall be submitted electronically to: Tina Robinson@ Robinsti@mail.nih.gov Quotations are due no later than: August 6, 2026, prior to 9:00 AM Eastern Daylight Time Late submissions may be rejected and not considered for award.


7.CLAUSES AND PROVISIONS The following FAR provisions and clauses apply to the open market items, in addition to any others required by law or agency policy: FAR Provisions • FAR 52.212-1, Instructions to Offerors—Commercial Products and Commercial Services • FAR 52.212-2, • FAR 52.204-7, System for Award Management • FAR 52.204-13, System for Award Management Maintenance FAR Clauses • FAR 52.212-4, Contract Terms and Conditions—Commercial Products and Commercial Services • FAR 52.232-25, Prompt Payment • FAR 52.232-40, Providing Accelerated Payments to Small Business Subcontractors HHSAR Clauses ,52.225-2 Buy American Certificate• HHSAR 352.203-70, Anti-Lobbying • HHSAR 352.208-70, Printing and Duplication • HHSAR 352.222-70, Contractor Cooperation in Equal Employment Opportunity Investigations • HHSAR 352.232-71, Electronic Submission of Payment Requests.

More opportunities from Department Of Health And Human Services → National Institutes Of Health Nichd

Same awarding agency

NAICS: 334510
New
Federal
Equipment: 7T MRI System with a dedicated, high-performance, local gradient subsystem.
Solicitation # RFP-2026-NIH-7TMR
The National Institutes of Health (NIH) is seeking a single-award, Firm-Fixed-Price contract for the acquisition and turn-key installation of a research-dedicated 7-Tesla (7T) Ultra-High Field Magnetic Resonance Imaging (MRI) system at the Functional Magnetic Resonance Imaging Core (FMRIF) Center in Bethesda, Maryland. The scope of work includes the delivery of the MRI system and a high-performance local gradient subsystem, professional project management, specialized rigging and mechanical installation within Building 10, and the de-installation and removal of an existing legacy Siemens 7T Plus system. The contractor is responsible for all freight, customs, and site-specific logistics, assuming full financial liability for the delivery pathway and any potential damage to NIH infrastructure. The period of performance is established as 18 to 24 months from the date of award. Technical requirements are stringent, mandating a superconducting 7.0T magnet with specific field homogeneity and drift rates, a local head gradient system with a peak amplitude of at least 200 mT/m and a slew rate of 900 T/m/s, and an 8-channel parallel transmit array. The system must support advanced neuro-MRI and spectroscopy, providing NIH staff with original source code for pulse sequences and raw data access. Award will be based on a Best Value Tradeoff, prioritizing technical performance, research openness, and integration capabilities over the lowest cost. Eligibility is strictly limited to prime offerors who attended the mandatory site visit on September 3, 2026. Final government acceptance is contingent upon successful on-site calibration and a continuous 24-hour imaging performance verification run.
Electromedical and Electrotherapeutic Apparatus Manufacturing

POSTED

2 days ago

DEADLINE

in 7 days
View Details
NAICS: 541715
Federal
Chemistry Research for the Division of Translational Toxicology (DTT)
Solicitation # 75N94026R00002
Solicitation 75N94026R00002 is a request for proposals to provide comprehensive chemistry research services for the National Institute of Environmental Health Sciences (NIEHS), specifically supporting the Division of Translational Toxicology (DTT) and the National Toxicology Program (NTP). The contract is structured as a multiple-year cost-reimbursement type completion contract with a base period from January 18, 2027, to January 17, 2008, and nine subsequent 12-month option periods, potentially extending the performance through July 17, 2037. The scope of work encompasses eight functional areas: Logistics and Handling, Characterization, Formulation, Biosample Analysis, Special Studies, Animal Studies, Omics, and In Vitro Assays. All research must adhere to DTT Chemistry Specifications, FDA Good Laboratory Practices (21 CFR 58), EPA Quality Management Plans, and USP XXIII standards. The award process emphasizes best value, utilizing a tradeoff approach where technical experience and past performance are significantly more important than cost. Proposals are evaluated using adjectival ratings, and a minimum small business participation of 5% of the total contract value is required to avoid a deficiency. Key personnel requirements include a Principal Investigator and a Deputy PI. Offerors must provide verification of IACUC approval for any work involving live vertebrate animals and submit a Health and Safety Chemical Hygiene Plan. Proposals must be submitted electronically via the NIH eCPS website, with the final deadline set for September 14, 2026. Inspection and acceptance of services will be conducted at Research Triangle Park, North Carolina.
Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)

POSTED

9 days ago

DEADLINE

in 3 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS