Main Condenser A-2 Cleaning, Gerald Gentleman Station
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The Nebraska Public Power District is soliciting bids for a turnkey project to perform high-pressure, hands-free water jet cleaning of the A-2 Main Condenser at the Gerald Gentleman Station in Sutherland, Nebraska. The scope of work involves cleaning the inside diameter of 15,916 tubes, excluding approximately 154 previously plugged tubes. Each tube must be cleaned for two minutes at 20,000 psi. To ensure 24-hour coverage, the contractor must operate two 12-hour shifts per day and perform cleaning simultaneously in two waterboxes. Bids are due by January 18, 2027, and must be submitted electronically to Greg Trofholz and Josh Dold. An optional pre-bid meeting and site visit is scheduled for January 5, 2027. Award selection will be based on the lowest and best bid from a responsible bidder, with evaluation factors including quoted price, technical conformance, bidder experience, and financial responsibility. Bidders must demonstrate a minimum of five years in business and have completed at least three similar projects within the last five years. Required submissions include a high-level project schedule, technical approach, OSHA 300 and 300A logs for the last three years, and QA/QC procedures. The contractor is required to maintain general liability insurance with a $1,000,000 per occurrence limit and comply with strict site safety and security protocols, including the prohibition of wooden or aluminum ladders and unauthorized camera use. Payment terms are set at thirty calendar days after receipt of invoice. There is no specified set-aside status for this solicitation.
General Info
Place of Performance
Set-Aside
Documents
2Read all 2 documents
Due in 55 daysEvery page of every file, in your free workspace.
Read the documentsAI Contract Breakdown
Uniform Contract FormatSign up to view the full breakdown with detailed analysis of each section.
View Full BreakdownEverything you need to bid on this one
Open the full contract in your free workspace.
- 2 solicitation documentsRead every page
- AI contract breakdown13 sections, Uniform Contract Format
- Buyer contactEmail and phone
Ask CLEATUS
I've read this contract. Ask me anything.
Timeline
Solicitation
The notice description changed.
Submission deadline
Response Deadline
Organization & Contact Information
Full Description
Nebraska Public Power District (DISTRICT) intends to procure all labor, supervision, mobilization/demobilization, equipment, tools, and supplies necessary to perform high pressure, hands free, water jet cleaning of the A-2 Main Condenser at Gerald Gentleman Station.
Details regarding this project can be found under the "Documents" tab.
PRE-BID MEETING? Yes - Optional PRE-BID MEETING DATE AND TIME 1/5/2027 10:00 AM PRE-BID MEETING DETAILS A non-mandatory pre-bid meeting and site visit for prospective Bidders will be held at GGS, located at 6089 South Highway 25, Sutherland, Nebraska, on January 5, 2027, at 10:00 a.m., CST, for the purpose of reviewing the Contract specifications, the work site and to answer any questions or clarifications the Bidder may have concerning the Contract requirements. It is the Bidder’s responsibility, while participating in the pre-bid meeting and site visit, to ask any questions necessary to understand the requirements of the Contract so the Bidder can submit a bid that is complete and according to the specifications. It is highly encouraged that all prospective Bidders attend this meeting. If you plan to participate, email Sarah Hopwood at •••••@•••••.•••Sign up to see this detail with the names of those representatives planning to participate in this pre-bid and the company they represent.
Please indicate your company's intent to bid.
Undecided No Bid Will Bid Notes Submit Intent BID CATEGORIES (4 records) CODE TITLE FULL NAME C690 Condensers and Accessories C690 Condensers and Accessories C691 Condenser Tubes C691 Condenser Tubes H160 Heat Exchangers - Equipment Cooling Water (Feedwater Heaters) H160 Heat Exchangers - Equipment Cooling Water (Feedwater Heaters) T790 Tube Cleaning T790 Tube Cleaning
Similar Contracts
Same NAICS industry code
More opportunities from Nebraska Public Power District
Same awarding agency
Earlier notices in this NAICS code
Posted before this notice, open and closed
Get AI-powered intelligence on this solicitation and the ones like it
Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.
Join 900+ contractors already using CLEATUS