Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on February 11, 2009. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Maintain/Upgrade Base Water System

Closed
FBNV090003A-BFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont in North Carolina with a project estimate of 16,690,000 dollars. The scope of work involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and comprehensive upgrades to the Morgans Branch Pumping Station. Key infrastructure improvements include the installation of a new wet well, valve vault, and associated appurtenances, as well as the demolition of existing pumps and piping. The contractor is responsible for delivering a fully operational station featuring mechanical and electrical systems, including pumps, a generator, and odor control equipment, along with new gravity sewers and manholes. The contract is a small business set-aside and will be awarded to the responsible bidder submitting the lowest responsive bid. Bids must be submitted using the EJCDC C-410 form and include a bid bond, evidence of signing authority, and MWBE compliance documentation. Performance and payment bonds are required upon award. Project administration follows EJCDC standard general and supplementary conditions, with payments processed monthly via applications for payment reviewed by the Engineer. Final acceptance is contingent upon a substantial completion inspection, the resolution of a punch list, and a final inspection conducted by the Owner, Contractor, and Engineer.
Don Moorhead Construction, Inc.

POSTED

about 3 hours ago

DEADLINE

in 20 days

General Info

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

Davis-Monthan AFB, AZ, 85707, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4877 355 Cons Pk
Contacts2 people available
OfficeDAVIS MONTHAN AFB, AZ, 85707-3522, USA
Office AddressDAVIS MONTHAN AFB, AZ, 85707-3522, USA
Contacts
Daniel B. ThelenContracting Officer
Eric ChaseContract Administrator

Full Description

Show more
THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. The 355th Contracting Squadron, Davis-Monthan AFB, AZ, is seeking potential sources qualified to perform maintenance and new construction on the base water system. The purpose of the Sources Sought notice is to identify the availability of qualified small business sources for a potential Historically Underutilized Business Zone (Hub Zone), Section 8(a), or Service-Disabled Veteran-Owned Small Business (SDVOSB) program set-aside. The anticipated contract will be a Firm Fixed Price contract with a magnitude between $5,000,000 and $10,000,000. Work to be performed under the contract will be within the North American Industry Classification System (NAICS) code as 237110 - Water and Sewer Line and Related Structures Construction. The Small business size standard is $33.5M. The following tasks are anticipated: 1. Construction of various water mains on base, construction of a grit removal plant, and construction of well pump shelters. 2. Repair of water wells, water distribution system, and wastewater collection system. This will include drilling three new wells, increasing the size of two existing wells, replacing well controls, replacement of water mains, replacement of a 200,000 gallon water storage tank, and replacement of faulty fire hydrants and water valves. All drilling work must be accomplished by a certified well driller licensed by and registered with the Arizona Department of Water Resources. If you have the capability and are interested in this acquisition, submit a detailed capability statement and evidence of past performance of this type of work in the past three years. In addition, provide a point of contact with phone and e-mail information, business status (socio-economic factors), business size based on NAICS 237110, and a positive statement of interest to submit a proposal. ** This sources sought notice is for informational and planning purposes only. It does not constitute a solicitation and is not to be considered as a commitment by the Government. All firms responding to this source sought notice are advised that their response to this notice is not a request that will be considered for contract award **

More opportunities from Department Of Defense → FA4877 355 Cons Pk

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS