Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

--Maintenance and repair service Philips IE33 Ultrasound unit for a period of performance: 1 October 2008 through 30 September 2009.

Active
W33BWP81508809Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The US Army Medical Command, Southeast Region, requires a sole source contract with Philips Medical System North America for a 12-month maintenance and service agreement on the Philips IE33 Ultrasound system located at the Eisenhower Army Medical Center, Fort Gordon, Georgia. The contract covers the period from October 1, 2008, to September 30, 2009, and includes both scheduled preventive maintenance inspections and unscheduled remedial repairs. Services encompass all repair parts, provision of training for one Biomedical Technician, and 24-hour toll-free telephonic support. The contractor must adhere strictly to manufacturer recommendations, perform preventive maintenance typically in March each year, and ensure timely scheduling and completion of inspections. On-demand remedial maintenance must restore equipment according to manufacturer specifications, with a one-hour response time for critical failures and on-site service within four hours during normal business hours. The agreement mandates use of only new or OEM-certified refurbished parts, adherence to strict documentation and reporting procedures, and compliance with applicable federal and military standards. Software upgrades will be included, while hardware upgrades require prior approval and are offered at a discounted rate. The contractor is responsible for all logistics related to parts shipment unless the Government supplies parts. Service technicians must be factory-trained with a minimum of two years’ relevant experience, and communication in English is required. The contract prohibits employing current Department of Defense personnel and requires a 24-hour point of contact. Contractors must maintain equipment in serviceable condition without disrupting hospital operations and handle subcontractor performance if applicable. Detailed service reports are required post-maintenance or repair, documenting work performed, parts replaced, and equipment status. Although this is not a request for proposal, other capable entities may submit technical information for potential future consideration.

General Info

Sole source 12-month maintenance contract with Philips for IE33 Ultrasound at Eisenhower Army Medical Center.

Agency

N/A

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

Not specified

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
The US Army Medical Command, Southeast Region has a requirement for 12 months maintenance and service, Philips IE33 Ultrasound, at Eisenhower Army Medical Center, Fort Gordon, Georgia. The Government intends to award a sole source contract for this requirement. The suggested contractor is Philips Medical System North America, 2210 Bothell Everett Highway. Bothell, Washington 98021-8431 12 months Philips IE33 Ultrasound maintenance service for a Period of Performance: 1 October 2008 through 30 September 2009. Maintenance contract is to provide total scheduled and unscheduled maintenance to the Philips IE33 Ultrasound System located in Cardiology. To include all repair parts and training of 1 each Biomedical Technician. The contractor shall provide 24 hour per day toll free telephonic applications and technical support to assist in-house personnel in solving problems or failures that can be resolved quickly. Remote dial-in access shall be made available to the MTF if the service is offered to the contractors other clients, but must be specifically authorized by the Military Treatment Facility (MTF) prior to use. Preventive maintenance inspections shall include all services necessary, including calibrations and parts replacement, to keep the equipment in serviceable condition. Contractor shall follow the manufacturers recommendations and requirements in scope and execution. Contractor shall perform PMIs during the month of March. The Contracting Officers Representative (COR) will contact the contractor to request a PMI be scheduled for the month due, unless contractor has a technical representative assigned to the MTF in which case the contractor shall be wholly responsible to schedule and perform PMIs with no further direction from the COR. The contractor will contact the COR within 5 duty days of the original request for the PMI service to schedule the PMI date. PMIs will be completed no later than 20 days after initial contact for services, but always within the month they are due. Contractor shall maintain a sufficient supply of replacement parts in order to complete the PMI on time. Contractor will immediately apprise the COR of any actual or potential delays that will prevent the successful completion of the PMI in the month due. On call remedial maintenance is the service requested by Medical Maintenance through the contractors point of contact and is required to restore equipment to an operational condition within the manufacturers specifications. Remedial maintenance includes the inspection, testing, trouble shooting, servicing, re-calibration (if incidental to repair), and all other actions necessary to return item to full service state. Remedial maintenance includes all minor or major malfunctions of the equipment systems and subsystems itself and not as a result of damage to the equipment by accident, neglect, abuse, power surge, power failure, or operation in an environment not compatible with the equipments published specifications, unless such damage is caused by the contractor. The contractors technician must notify the COR of any malfunctions resulting from damage to the equipment by accident, neglect, abuse, power surge, power failure, or operation in an environment not compatible with the equipments published specifications anytime these actions are the probable cause of the malfunction and regardless of who is at fault. Contractor will respond within one (1) hour of receiving call from COR or Medical Maintenance requesting service and will be on-site within four (4) hours for critical system/equipment malfunctions in which said equipment is inoperable. On site support shall be between the hours of 8:00 AM through 5:00 PM Monday through Friday excluding federal holidays. Overtime charges for any service performed by contractor after standard hours must be pre-approved by COR or Chief, Equipment Management Branch. Recalls, Field Change Orders, and Upgrades: Recalls and manufacturer initiated field changes shall be performed expeditiously. Notification of same shall be made to Chief, Equipment Management Branch immediately when initiated and upon completion. Upgrades to applications and/or operating system software will be included in the contract price and will be performed when available from the manufacturer, unless such an upgrade would require a non-covered hardware upgrade. Software packages will be kept current with the latest releases. Upgrades to hardware that are not covered under this contract will be offered to the Government and will reflect at least a 30% discount. No hardware upgrade will be initiated without the express consent of the COR. The contractor shall use only new or refurbished repair parts. The parts must meet OEM specifications. All refurbished shall be quality tested by the OEMs Quality Assurance Department and be certified as meeting the OEMs minimum requirements. Non-OEM parts must be approved by the COR prior to installation. The contractor must provide written evidence from OEMs or parts suppliers, of their ability to obtain parts that meet OEM specifications and in the quantities and times sufficient to meet the terms of the contract, if requested by the Government. Warranties of parts used in the repair shall meet or exceed that of the OEM. After completion of each service, the contractor will ensure the equipment is in compliance with the latest published editions of NFPA-99, manufacturers specifications, and Federal and DOD guidelines, regulation, performance standards, and specifications. The Contractor will provide all parts and incidentals for repairs and PMIs at no additional cost to the government. Upon request by the COR, parts replacement shall require written approval by the COR or technical representative prior to installation. The Government reserves the right to furnish replacement parts, to include x ray tubes, for the equipment covered by this contract. On request, the contractor will provide the Government the parts that were replaced by non- exchange parts. Freight, postage, and storage charges associated with shipment and receipt of replacement parts and the return of worn or defective parts shall be the responsibility of the contractor, unless said parts are supplied by the Government. Cost of priority shipping, when authorized in writing by the COR to meet emergency situations, may be added to the cost of the part and billed as one single item line on the invoice. Approval or non approval does not relieve the contractor from meeting timeframes established in the contract. It is the contractors responsibility to provide a trained, qualified technician with travel, expenses, parts, labor, literature, tools, test equipment, and software necessary to maintain and repair the listed equipment to manufacturers published specifications. Hardware upgrades are not included. The contractor shall obtain, have on file, and make available to all operational and technical documentation necessary to meet the performance requirements of this contract. Government literature of non proprietary nature, if deemed appropriate by the COR, may be made available to the contractor. (The government may not possess all literature for the equipment in its inventory). Contractors service representative shall have factory training and at least two (2) years of experience working on the contracted equipment. All contractors service personnel shall read, understand, fluently speak, and legibly write English. The Contractor shall not employ current DOD employees, military or civilian, to provide services under this contract. Contractor shall provide a POC who can be reached 24 hours a day. If the contractor changes the POC, the government shall be notified in writing 5 days prior to change. This is a non personal contract whereby Contractor personnel are considered employees and/or subcontractors of the Contractor and not subject, either by the contract terms or by the manner of its administration, to the supervision and control usually prevailing in a relationship, between the Government and its employees. The Government may evaluate the quality of professional and administrative service provided, but it retains no control over the professional aspects of services rendered. Performance of work by the contractors personnel under the terms of this contract shall not interfere with regularly scheduled Government operational activities. The contractor shall be responsible for the quantity and quality of services rendered by others who are subcontracted by the contractor for equipment that can not be serviced by the contractor for whatever reason. For all preventive or remedial services that require the calibration and/or calibration verification of equipment, the contractor shall complete DD Form 2163 (Medical Equipment Verification/Certification) in accordance with instructions provided in TB 38-750-2. This form will be provided by Dwight D. Eisenhower Army Medical Center. The contractor shall make every effort to perform the service in the MTF. However, if this is not feasible, the contractor assumes responsibility for equipment sent to their facility or to that of a subcontractor for the performance of this service. Contractor shall not remove any equipment displaying a serial number or Equipment Control Number (ECN) from the building without approval from the Section NCOIC, Property Book Officer, or Chief, Equipment Management Branch. The contractor shall arrange for and provide shipping to and from the remote location at no further charge to the Government. Upon completion of services, a written Service Report shall accompany the equipment being returned to include at a minimum, the time required to complete the work, price of labor (hourly rate), and a list of parts replaced with prices for each part, if applicable. The service report for preventive maintenance services shall provide detailed information regarding the results of the preventive services, any corrective action taken, and a statement regarding its operational status. The service report for remedial repair shall include the cause of the equipment malfunction and corrective action taken. If calibration was necessary as a result of the repair, a statement shall be included with the results of that calibration. Contractor shall also provide a statement regarding the operational status regardless of whether or not calibration was required or performed. No equipment displaying a serial number and not belonging to the Army or the MTF shall be left in the MTF without authorization from one of the aforementioned personnel. All such equipment left at the hospital could be considered Army property after thirty (30) days. This is not a request for proposal. However, entities that can provide an equal product must submit their technical capabilities to include certifications/licenses and Curriculum Vitae, past performance information, price and delivery time. This information will be reviewed by the Government medical/technical representatives for consideration for future requirements.

Similar Contracts

Same NAICS industry code

NAICS: 334510
New
Federal
Hearing Aid Fitting and Verification for Shiprock Service Unit (IEE or ISBEE Set Aside)
Solicitation # SS-SRSU-27-0003
The Indian Health Service Shiprock Service Unit is conducting market research through a sources-sought notice to identify capable Indian-owned economic enterprises, both large and small, to provide hearing aid fitting and verification services. The primary objective is to reduce hearing aid rejection and costly remakes while ensuring patients receive optimal benefit from their devices. The requirement includes the provision of equipment with advanced technical specifications, such as dual ear capability, a frequency range of 200 to 16,000 Hz, and a comprehensive test suite including speechmap counseling and pediatric probe tube placement. Additionally, the selected vendor must provide installation and training for the Audiology Department. This opportunity is categorized under NAICS code 334510 for electronic hearing aid manufacturing. In accordance with the Buy Indian Act, the government will prioritize responses from Indian-owned economic enterprises before considering other small business set-aside programs. Interested parties must be registered in the System for Award Management and submit a company profile, a capability statement, and a completed IHS IEE Representation Form by November 03, 2026. This notice is for market research purposes only and does not constitute a formal solicitation.
Navajo Area Indian Health Svc

POSTED

1 day ago

DEADLINE

in 5 days
View Details
NAICS: 334510
New
Federal
6515--ForeSite SS Tablet w/Pressure Mapping Sensor System
Solicitation # 36C24827Q0082
The Department of Veterans Affairs, through Network Contracting Office 8, is conducting market research via a Sources Sought Notice to identify authorized sources for the ForeSite SS Tablet Pressure Mapping System manufactured by ForeSite Medical. This effort is for acquisition planning purposes and is not a formal solicitation. The required system is intended for clinical pressure assessment and treatment and must include the tablet platform, pressure-mapping sensors, sensor packs, chargers, software licenses, cables, and all necessary accessories. Key functional requirements include real-time pressure analysis and visualization, patient data storage and reporting, wireless and wired connectivity, and portable battery-powered operation. All equipment must be new and include the manufacturer's standard warranty. Interested vendors must submit electronic responses in PDF or Word format by October 30, 2026. Submissions must include the company name, address, Unique Entity Identifier, point of contact, and business size or socioeconomic status, such as SDVOSB, VOSB, Small Business, or Large Business. Additionally, respondents must provide documentation proving they are authorized to distribute or resell the ForeSite system, an estimated delivery lead time, and confirmation regarding the new condition and warranty of the product. The place of performance is located in Tampa, Florida, under NAICS code 334510.
248-NETWORK Contract Office 8 (36C248)

POSTED

3 days ago

DEADLINE

in about 12 hours
View Details
NAICS: 334510
New
Federal
Ocular Scanner
Solicitation # W91CRB-26-AWSP-Scanner-Ultrasonic-Ocular-RPP
The Portfolio Acquisition Executive Maneuver Ground Project Manager Maneuver Medical Systems is soliciting prototype proposals for a Scanner Ultrasonic Ocular device under Other Transaction Authority pursuant to 10 U.S.C. 4022. The objective is to award two prototype agreements for the delivery and demonstration of FDA-approved commercial solutions that provide anatomical visualization and diagnostic imaging of the eye, specifically for the anterior and posterior segments. Awardees are required to deliver four prototype units within 45 to 60 days of award for operational and environmental testing conducted in accordance with MIL-STD-810H. The estimated period of performance is twelve months, with awards expected around the first quarter of fiscal year 2027. The procurement utilizes a comparative best-value methodology, prioritizing technical approach, performance compliance, reliability, schedule realism, and past performance over cost. Key requirements include Trade Agreements Act compliance, MIL-STD-130N marking for hardware, and the provision of ruggedized transport cases. Deliverables encompass the hardware units, comprehensive user and maintenance manuals, cybersecurity documentation, and on-site operator training. Proposals must be submitted as four separate PDF volumes via DoD SAFE or secure email by November 12, 2026. This action is a direct Other Transaction Agreement and is not subject to the Federal Acquisition Regulation or Defense Federal Acquisition Regulation Supplement.
W6QK Acc-Apg

POSTED

3 days ago

DEADLINE

in 14 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS