Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on April 22, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Mud Mountain Dam Lower Cascade Creek Water Control Facility

Closed
W912DW24B0008Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

237

Place of Performance

Enumclaw, WA, 98022, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W071 Endist Seattle
Contacts2 people available
OfficeSEATTLE, WA, 98134-2329, USA
Office AddressSEATTLE, WA, 98134-2329, USA
Contacts
Jeannette Patton
Enshane Hill-Nomoto

Full Description

Show more
This SOURCES SOUGHT ANNOUNCEMENT for IFB W912DW24B0008 is for informational and market research purposes only. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS, OR BIDS, NOR A SYNOPSIS OF A PROPOSED CONTRACT ACTION UNDER FAR SUBPART 5.2. The proposed action will be a construction project with a firm-fixed price contract. The type of solicitation to be issued will depend upon information received in response to this sources sought announcement. No reimbursement will be made for any costs associated with providing information in response to this sources sought announcement or any follow-up information. We anticipate this to be evaluated as Low Price, Technically Acceptable (LPTA). Responses to this sources sought announcement will be used by the Government to make appropriate acquisition decisions. NO SOLICITATION IS CURRENTLY AVAILABLE. This is not a request to be placed on a solicitation mailing list and is not to be construed as a commitment by the Government. The results of this survey will be considered to be in effect for a period of one year from the date of this notice. The purpose of this sources sought announcement is to gain knowledge of potentially qualified Small Business, 8(a), Woman Owned Small Business, Service-Disabled Veteran Owned Small Business, and HUBZone contractor sources; as well as their size classifications relative to the NAICS code 237990 - Other Heavy and Civil Engineering Construction, PSC code Y1PZ-Construction of Other Non-Building Facilities, and Small Business Size Standard $45 Million. Depending upon the responses associated with the business categories listed above, the solicitation will either be set aside in one of those categories or be issued as unrestricted and open to both small and large businesses. After review of the responses to this announcement and if the Government still plans to proceed with this project; a separate solicitation announcement will be published on SAM.gov (www.SAM.gov). Responses to this announcement are not an adequate response to any future solicitation announcement. BACKGROUND: Mud Mountain Dam is a zoned earth and rockfill structure with an 810-foot-long crest and a maximum height of 432 feet above bedrock. The structural height of 427 feet is measured from the bottom of a structural depression located approximately 170 feet upstream of the cutoff wall to the new top of dam at 1,257 feet NGVD29. The dam is 1,600 feet wide at the base, 25.5 feet wide at the crest, with a design crest elevation of 1,257 feet NGVD29. A concrete seepage cutoff wall extends from the crest into bedrock in the core of the dam. Mud Mountain Dam is constructed in a narrow canyon where rock walls on both sides of the gorge rise almost vertically to a height of nearly 275 feet above the White River channel. The upstream hillside slope at the left abutment is steep (approximately1:1). Lower Cascade Creek (LCC) drains into an existing Water Control System (WCS) consisting of debris screens, a concrete lined catch basin and pipes which convey flow along the upstream left groin to the pool. The upstream groin is armored with shotcrete to approximate EL 1167.8 feet (NAVD88). The catch basin and embankment abutment tie-in are separated by roughly 51 feet of sandy-gravel fill between EL 1,267.8 feet (NAVD88) (basin) and 1,264.3 feet (NAVD88) (crest). The current WCS was not designed to a handle a specific flow or event with a defined return interval, because there is very little available hydrologic data on flow-frequency for LCC. Rather, the existing inlet basin was constructed to address recurring erosion caused by flows from past events along the upstream groin. This lack of a specific design event or flow has led to failure to control flows at the inlet even without debris accumulation. The LCC watershed is approximately 0.4 square miles or 0.1 percent of the Mud Mountain Dam watershed. Additionally, the watershed for LCC is immediately adjacent to the dam making it very likely that a large precipitation event would load both watersheds as it moves across the region. Due to the size and nature of the watershed, peak flows on LCC occur sooner and have a shorter duration than those observed on the White River. Consequently, high flows occur on LCC before much of the precipitation in the White River basin concentrates and begins to raise the reservoir. CONSTRUCTION REQUIRED: The purpose of this project is to replace an outdated and inefficient water control structure incapable of containing high water volumes from LCC. In 2009, a flood event overtopped the water control structure, and uncontrolled creek flows eroded both the upstream and downstream left groin of the dam causing extended disruption to project operations. MAGNITUDE OF CONSTRUCATION: In accordance with DFARS 236.204(ii) - Disclosure of the Magnitude of Construction Projects, Magnitude of Construction is estimated to be between $10,000,000 and $25,000,000. REQUIREMENTS: Interested firms should submit a capabilities package, to include the following: 1. Firm's name, address, point of contact, phone number, and email address. 2. CAGE code and Unique Entity ID (UEI) number[HNELC(3] [PJK(CUC(4] . 3. Firm's interest in bidding on the solicitation if issued. 4. Business classification: Small Business (SB), Small Disadvantaged Business (SDB), Woman Owned Small Business (WOSB), Veteran Owned Small Business (VOSB), Service Disabled Veteran Owned Small Business (SDVOSB), Historically Underutilized Business Zone Small Business (HUBZone), 8(a) Program, Other Than Small Business (Large Business). 5. Firm's joint venture information (if applicable). All interested parties who believe they can meet the requirements are invited to submit, in writing, complete information describing their interest and ability to meet all requirements stated above. Prior Government contract work is not required for submitting a response to this announcement. Submit responses via email to: Jeannette K. Patton, Contract Specialist, jeannette.k.patton@usace.army.mil AND Enshane Hill-Nomoto, enshane.nomoto@usace.army.mil.. Responses should be sent as soon as possible, but no later than 10:00 AM PST, 22 May 2024. Subject Line: MMD Lower Cascade Creek Water Control Facility Vendor Source All interested firms must be registered in the System for Award Management (www.SAM.gov) by time of award and remain active for the duration of the contract to be eligible for Government contracts.

More opportunities from Department Of Defense → W071 Endist Seattle

Same awarding agency

NAICS: 236220
New
Federal
JOINT BASE LEWIS MCCHORD MULTI DOMAIN TASK FORCE BUILDINGS 3223-3224, WASHINGTON
Solicitation # W912DW27RA014
Solicitation W912DW27RA014 is a Total Small Business Set-Aside for a Firm Fixed Price contract to convert two existing barracks buildings, known as the Hammer Heads, into operational facilities for three tier levels of command for the Multi Domain Task Force at Joint Base Lewis McChord, Washington. The project involves the repair and renovation of Building 3223, which will serve as BSB Administration, Readiness, and Troop Aid, and Building 3224, which will serve as the COF and BSB BN HQ. The scope of work includes site preparation, demolition, utility and roadway construction, asbestos and lead-based paint abatement, and the installation of telecommunications equipment. The estimated construction magnitude is between 40 million and 70 million dollars, with a mandatory performance period of 730 calendar days from the date of the Notice to Proceed. The contract will be awarded based on a Best Value Tradeoff, where non-price factors, including past performance and a project narrative with a summary schedule, are significantly more important than price. Bidders must be registered in the System for Award Management and provide a bid guarantee. Key requirements include adherence to the Davis-Bacon Act, Buy American requirements for construction materials, and the provision of as-built drawings and operation and maintenance manuals upon completion. Proposals must be submitted electronically via the Procurement Integrated Enterprise Environment Solicitation Module in two separate PDF volumes.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in about 1 month
View Details
NAICS: 541380
New
Federal
CJD National Pollutant Discharge Elimination System (NPDES) Laboratory Services - Base plus 4 Option Years
Solicitation # W912DW27QA001
The U.S. Army Corps of Engineers, Seattle District, is soliciting quotes for a firm-fixed price purchase order to provide accredited laboratory analytical services for the Chief Joseph Dam Project in Bridgeport, Washington. The primary objective is to ensure compliance with National Pollutant Discharge Elimination System permit limits specifically for Oil and Grease. The contract includes a base year running from November 1, 2026, to October 31, 2027, with four subsequent one-year options. The government anticipates approximately 540 samples per year, though actual quantities may vary. To be eligible, the laboratory must be located within 200 road miles of Bridgeport, Washington, and hold accreditation from the National Environmental Laboratory Accreditation Program or the Washington State Department of Ecology Environmental Laboratory Accreditation Program. The contractor is responsible for providing all necessary sampling kits, coolers, and shipping materials, as well as managing regularly scheduled pickups and deliveries. Analytical results must be submitted electronically in searchable PDF format within 10 business days of sample receipt. This solicitation is set aside for Women-Owned Small Businesses and will be awarded to the lowest priced conforming quote.
Testing Laboratories and Services

POSTED

4 days ago

DEADLINE

in about 22 hours
View Details
NAICS: 531120
Federal
DACA675270001300 - United States Army Corps of Engineers (USACE) seeks to lease approximately 555 gross square feet of office space in SeaTac, Washington for Air Mobility Command
Solicitation # DACA675270001300
The United States Army Corps of Engineers (USACE) is seeking proposals to lease approximately 555 gross square feet of professional office space in SeaTac, Washington. The required space must be located within the SeaTac airport, in proximity to the AMC Terminal office, and within a specific delineated area bounded by 154th Street, 188th Street, Military Road South, and Des Moines Memorial Drive South. The government requires a fully serviced lease for a term of five years, which must include base rent, common area maintenance, and utilities. Preference is given to ground-floor spaces that provide an efficient layout and meet all federal requirements for security, fire life safety, and handicapped accessibility. To be eligible, the space must not be located within a 100-year flood plain or wetland, nor near establishments primarily selling alcohol, firearms, or marijuana. The facility must be within 1,000 feet of regularly scheduled public transportation and provide 24/7 access for government personnel. Proposals must be submitted electronically by October 30, 2026, and include a completed Rental Proposal Worksheet, representations and certifications, and evidence of ownership. Award selection will be based on the best value, considering price, location, neighborhood quality, and the offeror's past performance. All offerors must be registered in the System for Award Management (SAM) at the time of lease award.
Lessors of Nonresidential Buildings (except Miniwarehouses)

POSTED

about 1 month ago

DEADLINE

in 10 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS